ABB 83327-500 User manual

Type
User manual

This manual is also suitable for

VER:1.0 12.10.2015
ABB-Welcome
Pos: 2 /DinA4 - A nleitungen Onlin e/Inhalt/KNX/D oorEntry/832 20-AP-xxx/Ti telblatt - 83 220-AP-xxx - ABB @ 19\ mod_1323249 806476_15.doc x @ 111084 @ @ 1
83327-500
Camera interface
=== Ende der List e für Textmarke Cover ===
|
2
Pos: 4 /Busch-Ja eger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/In haltsverzeichnis ( --> Für alle Dokumente <--)/Inhalts verzeichnis @ 19\mod_1320 649044386_1 5.docx @ 109653 @ @ 1
1 Safety ............................................................................................................ 3
2 Intended use .................................................................................................. 3
3 Environment .................................................................................................. 3
3.1 ABB devices ................................................................................. 3
4 Operation ....................................................................................................... 5
4.1 Control elements .......................................................................... 5
4.2 Operating modes .......................................................................... 6
4.2.1 Mode=1, works as an independent outdoor station ...................... 6
4.2.2 Mode=2, works associated with outdoor station ........................... 7
4.2.3 Mode=3, works associated with guard unit ................................... 8
4.2.4 Mode=4, programming mode........................................................ 9
4.3 Programming mode .................................................................... 10
4.4 With and without permanent power supply ................................. 11
4.5 Video signal from third party DVR .............................................. 12
4.6 Video signal to be stored to third party DVR ............................... 13
5 Technical data ............................................................................................. 14
5.1 Overview table ............................................................................ 14
5.2 Device connection diagram ........................................................ 14
6 Mounting/Installation .................................................................................... 15
6.1 Requirements for the electrician ................................................. 15
6.2 General installation instructions .................................................. 16
6.3 Mounting ..................................................................................... 17
6.3.1 Surface-mounted installation ...................................................... 17
6.3.2 Flush-mounted installation .......................................................... 17
6.3.3 DIN installation ........................................................................... 17
=== Ende der List e für Textmarke TOC ===
Safety
|
3
Pos: 6 /Busch-Ja eger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Übers chriften (--> Für alle Dokum ente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_13 02612791790 _15.docx @ 10335 7 @ 1 @ 1
1 Safety
Pos: 7 /Busch-Ja eger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Sich erheit (--> Für alle Doku mente <--)/Warnhin weise/Sicherheit - 2 30 V @ 18\m od_1302606816 750_15.docx @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
Work on the 100-240 V supply system may only be performed by
authorized electricians!
Disconnect the mains power supply prior to installation and/or
disassembly!
Pos: 8 /Busch-Ja eger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Übers chriften (--> Für alle Dokum ente <--)/1. Ebene/A - F/Bestim mungsgemäßer Gebrauch @ 18\mo d_13027633213 16_15.docx @ 103483 @ 1 @ 1
2 Intended use
Pos: 9 /DinA4 - A nleitungen Onlin e/Inhalt/KNX/D oorEntry/832 20-AP-xxx/B estimmungsg emaesser Ge brauch - 83220-AP-xxx- 500 @ 20\mod_1 32456116869 9_15.docx @ 1 12728 @ @ 1
This device integrates analog camera into the ABB-Welcome door entry system. Up to 4
analog cameras can be connected to 1 camera interface. Each external camera is
powered independently.
Pos: 10 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Übersc hriften (--> Für alle Doku mente <--)/1. Ebene/U - Z/Umwelt @ 18\mod_1302 614158967_1 5.docx @ 103383 @ 1 @ 1
3 Environment
Pos: 11 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/U mwelt (--> Für alle Dokumente <--)/Hi nweise/Hi nweis - Umwelt - Hi nweis Elektrog eräte @ 18\mod_1302 763973434_1 5.docx @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with
household waste.
The device contains valuable raw materials that can be recycled.
Therefore, dispose of the device at the appropriate recycling
facility.
Pos: 12 /DinA4 - Anleitungen Onli ne/Ueberschrif ten/2./ABB G eraete @ 19\m od_13231628438 32_15.docx @ 110875 @ 2 @ 1
3.1 ABB devices
Pos: 13 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/U mwelt (--> Für alle Dokumente <--)/Hi nweise/Hi nweis - Umwelt - ABB Ele ktrogeräte @ 19\mod_ 1323162745839_15. docx @ 110 867 @ @ 1
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packaging material and electric devices and their
components via an authorized recycling facilities or disposal companies.
Environment
|
4
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)
Operation
|
5
Pos: 18 /DinA4 - Anleitungen Onli ne/Ueberschrif ten/1./Bedienu ng @ 18\mod _13026139241 65_15.docx @ 103365 @ 1 @ 1
4 Operation
Pos: 19 /DinA4 - Anleitungen Onli ne/Ueberschrif ten/2./Norm aler Betrieb @ 18\ mod_1302768 820965_15.d ocx @ 103540 @ 2 @ 1
4.1 Control elements
Pos: 20 /DinA4 - Anleitungen Onli ne/Ueberschrif ten/3./Bedienel emente @ 20\ mod_132326 0220559_15.doc x @ 111647 @ 3 @ 1
Pos: 21 /DinA4 - Anleitungen Onli ne/Inhalt/KN X/DoorEntry/83 220-AP-xxx/Bedieneleme nte - 83220- AP-xxx @ 1 8\mod_13032 12853605_15.d ocx @ 103673 @ @ 1
Fig.
1
: Overview of control buttons
No.
Functions
1
Bus in
2
Bus out
3
CVBS out
4
Switch on camera power supply.
For details, please see Chapter 4.4 With & Without permanent power
supply
5
Working mode
There are 4 modes for the camera interface, For details, please see
Chapter 4.3 Operation mode.
6
Set the address of the associated devices.
7
Set the address of the camera interface.
8
Operating status notification LED
-Green: ready for operation
-Orange: in setting mode
-Red: fault
9
Dip switch to switch on/off the video channel.
10
Program button to enter the programming mode.
11
4 video in. (supports CVBS signal input)
Pos: 22 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/S teuermodule - Online-Do kumentation (--> Für alle Dokume nte <--)/++++++ ++++++ Seitenumbruc h +++++++++ +++ @ 9\ mod_1268898668 093_0.docx @ 52149 @ @ 1
Operation
|
6
Pos: 26 /DinA4 - Anleitungen Onli ne/Ueberschrif ten/2./Bediena ktionen @ 20\ mod_1323262 294281_15.docx @ 111911 @ 2 @ 1
4.2 Operating modes
Pos: 71 /DinA4 - Anleitungen Onli ne/Ueberschrif ten/3./Abschlus swiderstand @ 19\mo d_132195807 9906_15.docx @ 110083 @ 3 @ 1
Pos: 72 /DinA4 - Anleitungen Onli ne/Inhalt/KN X/DoorEntry/Be dienung/Abschl usswiderstand se tzen 83220- AP-xxx @ 1 9\mod_131072 3392369_15.d ocx @ 1078 41 @ @ 1
4.2.1 Mode=1, works as an independent outdoor station
Fig.
2
: Mode=1, works as an independent outdoor station
Rotary
Value
Note
Mode
1
Camera interface works as an independent camera interface.
Addr
null
——
ID
2
ID starts from 1 to 9 sequentially, and should not be the same
address of camera interface or other camera interface.
Pos: 74 /DinA4 - Anleitungen Onli ne/Inhalt/KN X/DoorEntry/Be dienung/Mast er/Slave Schalter s etzen 83220-AP- xxx @ 19\mod_1310 723320966_1 5.docx @ 10 7833 @ @
Dip Switch 1-4
Turn to ON when a camera is connected.
Capacity
Each camera interface supports 4 analog cameras.
A total 9 camera interfaces (mode=1) in one system.
Operation
Press to view the cameras individually during surveillance.
Operation
|
7
4.2.2 Mode=2, works associated with outdoor station
Fig.
3
: Mode=2, works associated with outdoor station
Rotary
Value
Note
Mode
2
Camera interface work associated with outdoor station.
Addr
1
Address of the associated outdoor station, from 1-9.
ID
1
ID can be set from 1-9, and should be unique.
Dip Switch 1-4
Turn to ON when a camera is connected.
Capacity
Each camera interface supports 4 analog cameras.
A total of 15 cameras can be associated with each outdoor station (including 2 built-in cameras in
outdoor station).
Operation
Press to view the cameras individually during surveillance.
Pos: 74 /DinA4 - Anleitungen Onli ne/Inhalt/KN X/DoorEntry/Be dienung/Mast er/Slave Schalter s etzen 83220-AP- xxx @ 19\mod_1310 723320966_1 5.docx @ 10 7833 @ @
Operation
|
8
4.2.3 Mode=3, works associated with guard unit
Fig.
4
: Mode=3, works associated with guard unit
Rotary
Value
Note
Mode
3
Camera interface work associated with guard unit.
Addr
1
Address of guard unit, from 1-9.
ID
1
ID can be set from 1-9, and should be unique.
Dip Switch 1-4
Turn to ON when a camera is connected.
Capacity
Each camera interface supports 4 analog cameras.
A total of 15 cameras can be associated with each guard unit.
Operation
During communication, image can be sent from guard unit to indoor station by pressing the
"Enable" button.
Pos: 75 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/S teuermodule - Online-Do kumentation (--> Für alle Dokume nte <--)/++++++ ++++++ Seitenumbruc h +++++++++ +++ @ 9\ mod_1268898668 093_0.docx @ 52149 @ @ 1
Operation
|
9
4.2.4 Mode=4, programming mode
Fig.
5
: mode=4, programming mode
Rotary
Value
Note
Mode
4
Camera interface works in programming mode.
Addr
null
Camera interface mode, camera interface address and associated device
address can all be programmed with software.
In mode=4, besides camera interface and guard unit, camera interface
can also be associated with video indoor station.
If camera interface is associated with video indoor station, ID should start
from 1 to 9 sequently.
For details, see Chapter 4.3 Programming mode.
ID
null
Dip Switch 1-4
Turn to ON when a camera is connected.
Capacity
Each camera interface supports 4 analog cameras. Each camera can be associated with
different devices (i.e., outdoor station, guard unit, video indoor station).
A total of 36 cameras can be associated with each video indoor station. Each camera can be
associated with 250 indoor stations.
Operation
|
10
4.3 Programming mode
start
1. Long press “
Prog button for 3s to
enter programming mode
2. Choose cameras to set by dip switch
V1/V2/V3/V4
4. Set the working mode by R1
Mode=1, Camera interface works as an independent
outdoor station.
Mode=2, Camera interface works associated with
outdoor station.
Mode=3, Camera interface works associated with
guard unit.
Mode=4, Camera interface works associated with indoor station
3. Assign the address of the camera
interface by R3
5. Short-press "
Prog" button to save current setting
6. Set the address of the associated
device by these three rotary switches
(R1&R2&R3)
Address=R1*100+R2*10+R3
continue to
program
8. Long press “Prog button 3s to exit
programming mode
End
7. Short-press "Prog" button to save
current setting
N
Y
R1
R2
R3
Operation
|
11
4.4 With and without permanent power supply
+
-
12V
+
-
12V
Camera with permanent power supply
Camera without permanent power supply
Operation
|
12
4.5 Video signal from third party DVR
Fig.
6
: Video signal from third party DVR
Note:
1) DVR output can be one of the inputs for camera interface in modes 1, 2, 3, and 4.
2) Each camera Interface supports 4 DVR singnals.
DVR
Operation
|
13
4.6 Video signal to be stored to third party DVR
Fig.
7
: Video signal to be stored to third party DVR
Note:
1) Camera interface sends video to video indoor station and also to DVR/TV through the
CVBS output port.
2) Each camera interface supports 1 CVBS output.
3) After connecting CVBS output to DRV/TV, there are two options for sending video to
DVR:
-Camera interface mode=2, video outdoor station calls video indoor station.
-Camera interface mode=3, "Enable" button is pressed at guard unit.
4) Camera interface doesnt send video to DVR/TV during video Indoor station
surveillance.
Pos: 75 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/S teuermodule - Online-Do kumentation (--> Für alle Dokume nte <--)/++++++ ++++++ Seitenumbruc h +++++++++ +++ @ 9\ mod_1268898668 093_0.docx @ 52149 @ @ 1
DVR
Technical data
|
14
Pos: 76 /DinA4 - Anleitungen Onli ne/Ueberschrif ten/1./Technisc he Daten @ 18\ mod_130261 5863001_15.d ocx @ 103416 @ 1 @ 1
5 Technical data
Pos: 77 /DinA4 - Anleitungen Onli ne/Inhalt/KN X/DoorEntry/83 220-AP-xxx/Technische D aten - 832 20-AP-xxx @ 18\mod_13 03212854559_15. docx @ 103 705 @ @ 1
5.1 Overview table
Designation
Value
Single-wire clamps
2 x 0.28 mm
2
- 2 x 0.75 mm
2
Fine-wire clamps
2 x 0.28 mm
2
- 2 x 0.75 mm
2
Bus voltage
20-30V DC
Protection
IP30
Operating temperature
-25 - +55
Video input
1Vp-p, PAL/NTSC
Video output
1Vp-p@75Ω, PAL/NTSC
Camera interface to camera
Coax cable, Max 100 metres
other cables, 10-50 metres
Size
77 mm x 61 mm x 25 mm
5.2 Device connection diagram
Pos: 78 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/S teuermodule - Online-Do kumentation (--> Für alle Dokume nte <--)/++++++ ++++++ Seitenumbruc h +++++++++ +++ @ 9\ mod_1268898668 093_0.docx @ 52149 @ @ 1
M2300
100~240
100~240
a b
One on
All on
a b
E
DC GND
M2231X
01 1
Station
X10 X1
M/S RC
X100 X200
2 core bus
1 core wire
M2308
IN
OUT OUT
a b a b CVBS GND 1413
12 1
MODE
V1+
V1
V1- V2+ V2- V3+ V3- V4+ V4-
V2 V3 V4
X1
12V
signal
Power
a b DC GND
LOCK COM NC NO
1
1 2 3 4
Address TT S/D
MODE
Camera
Mounting/Installation
|
15
Pos: 79 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Übersc hriften (--> Für alle Doku mente <--)/1. Ebene/M - O/Montage / Installation @ 1 8\mod_130 2613966111_15.d ocx @ 1033 73 @ 1 @ 1
6 Mounting/Installation
Pos: 80 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Sic herheit (--> Für alle Dokum ente <--)/Warnhinweis e/Sicherheit - Ni ederspannu ngs- und 230 V-L eitungen @ 18\mod_13 02617821491_15. docx @ 10346 5 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
Low-voltage and 100-240 V cables must not be installed together in
a flush-mounted socket!
In case of a short-circuit there is the danger of a 100-240 V load on
the low-voltage line.
Pos: 81 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Sic herheit (--> Für alle Dokum ente <--)/Warnhinweis e/Sicherheit - F achkenntniss e @ 18\mod_13 02774384017_ 15.docx @ 1 03564 @ 2 @ 1
6.1 Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
Incorrect installation endangers your life and that of the user of the
electrical system.
Incorrect installation can cause serious damage to property, such
as a fire.
The minimum necessary expert knowledge and requirements for the
installation are as follows:
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth;
5. Cover or barricade adjacent live parts.
Use suitable personal protective clothing.
Use only suitable tools and measuring devices.
Check the type supply network (TN system, IT system, TT system)
to secure the following power supply conditions (classic connection
to ground, protective earthing, necessary additional measures,
etc.).
Pos: 82 /DinA4 - Anleitungen Onli ne/Inhalt/KN X/DoorEntry/Mont age/Montage hinweise - Allge mein @ 19\ mod_13105636 70478_15.doc x @ 107743 @ 2 @ 1
Mounting/Installation
|
16
6.2 General installation instructions
Terminate all branches of the wiring system via a connected bus device (e.g.,
indoor station, outdoor station, system device).
Do not install the system controller directly next to the bell transformer and other
power supplies (to avoid interference).
Do not install the wires of the system bus together with 100-240 V wires.
Do not use common cables for the connecting wires of the door openers and wires
of the system bus.
Avoid bridges between different cable types.
Use only two wires for the system bus in a four-core or multi-core cable.
When looping, never install the incoming and outgoing bus inside the same cable.
Never install the internal and external bus inside the same cable.
Mounting/Installation
|
17
6.3 Mounting
Pos: 85.1 /DinA 4 - Anleitungen Online/Inhalt/KN X/DoorEntry/83 220-AP-xxx/Montage - M odule/Montage - Montage dose -- 83220-AP- xxx @ 19\mo d_132325040 6848_15.docx @ 111098 @ @ 1
6.3.1 Surface-mounted installation
6.3.2 Flush-mounted installation
6.3.3 DIN installation
Pos: 83 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/S teuermodule - Online-Do kumentation (--> Für alle Dokume nte <--)/++++++ ++++++ Seitenumbruc h +++++++++ +++ @ 9\ mod_1268898668 093_0.docx @ 52149 @ @ 1
Mounting/Installation
Pos: 95 /DinA4 - Anleitungen Onli ne/Inhalt/KN X/DoorEntry/Pr ojektierung-Mer kblatt/Proje ktierPos: 97 /Busch-J aeger (Neus truktur)/Modul-Str uktur/Online-Do kumentatio n/Rückseiten (--> Für alle Dokumente <--)/Rückseite - B usch-Jaeger - Allgemein @ 2 0\mod_13273 20074886_ 15.docx @ 137103 @ @ 1
Notice
=== Ende der List e für Textmarke Backco ver ===
We reserve the right to, at any time, make technical changes or changes in the content
of this document without prior notice.
The detailed specifications agreed to at the time of ordering applies to all orders. ABB
accepts no responsibility for possible errors or incompleteness in this document.
We reserve all rights to this document and the topics and illustrations contained therein.
The document and its contents, or excerpts thereof, must not be reproduced,
transmitted or reused by third parties without prior written consent by ABB.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

ABB 83327-500 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI