JUNG TKVU4 Operating instructions

Category
Door intercom systems
Type
Operating instructions
1
Product Information
DCM Video switch 4-gang
TK VU 4 REG
Safety instructions
!
Assembly, installation, and commissioning must only be carried out by a qualified
electrician
For work on systems with 230 V AC mains current the safety requirements of DIN VDE
0100 must be observed.
When installing DCM BUS systems the general safety rules for telecommunication sys-
tems in accordance with VDE 0800 must be observed:
separate cabling for high and low voltage lines
minimum distance of 10 cm for joint cabling arrangements,
use of separators between high and low voltage lines in joint cable ducts,
use of standard telecommunication cables, e. g. J-Y (St) Y with 0.8 mm² cross section
!
Suitable lightning prediction must ensure that a voltage of 32 V DC will not be
exceeded at the DCM BUS wires a and b.
DCM = Door Communication Management
2
Device overview
Technical data
Input voltage: + 24 V ± 8 % (Power supply &control unit)
Housing: rail mounting device, 6 rail units
Weight: 200 g
Permissible ambient temperature: 0 °C to 40 °C
Input current: I(a) = 0.4 mA, I(P) = 21 mA
Run/Pro
g
-button
Run/Prog-indication
Ste
p
terminal
Hold terminal
Output terminal
Terminals for camera input 1-3
Terminals for camera input 4
3
Application
The TK VU 4 REG is designed to switch between four video signals, which will be received
of one (or more) video indoor stations.
Up to 4 video switches can be installed in a DCM system. In this case the output terminals
(3-7) will be wired parallel. Please install the all video switches side by side in the distribu-
tion board to achieve the best camera image quality.
!
In an installation with multiple video switches, you have to finish all required program-
ming steps before you trigger a bell button or start a communication. Otherwise multiple
video signals will be switched on at the same time.
Brief description
Functions
Automatic switching to the triggered outdoor station
Video inputs 4
Video outputs 1
4
Cable connection
Wiring diagram
Wiring example
Video outdoor station 1:
AS-address = 01
program and lock
Video outdoor station 2:
AS-address = 02
program and lock
Audio outdoor station 3:
AS-address = 03
program and lock
Video input 4 not connected
Program input as "unused" !
V
ideo outdoor
station 1
V
ideo outdoor
station 2
5
Commissioning
Install all of the devices of the system completely.
Check the a, b and P wires for short-circuit.
Switch on the mains voltage.
!
Please complete the full installation before you connect the system to
the mains voltage!
Do NOT connect V1 and V2 with the P-, M-, a- or b-wire. Even a connection for a
quick moment will destroy the device.
When connecting the video wires V1 (+) and V2 (-) observe polarity.
If you can see a distorted image on the display, switch off the mains voltage and
change the wires V1 and V2..
Settings
Factory setting
The inputs S1, S2, S3, S4 are pre-programmed with the AS-addresses 1, 2, 3 and 4.
Device settings
You can program the video switch with the service device TK-SERVICE or the
commissioning software TK-IBS-TOOL.
Each outdoor station has to be assigned with an AS-address. The AS-address has to be
locked. Thus every door call transmitted the respective AS address of the outdoor station.
The video switch allocates the video inputs to the respective AS addresses. A video input
will be automatically activated with a triggered door call. The AS-address of the video input
has to comply with the AS-address of the outdoor station.
The combination with audio outdoor station is possible.
!
Caution!
Link outdoor stations without camera with AS-addresses greater 31
and lock the programmed AS-addresses.
!
Caution!
Video outdoor stations or cameras without outdoor stations have to be linked
with available AS addresses from 0 to 30.
Please only use the function: "Connect camera input with video outdoor station".
6
Example
Connection of 2 video outdoor stations to the camera inputs S1 and S2.
Assign the AS-addresses of the outdoor stations to AS=1 and AS=2 and lock
the AS-addresses ( with service device or commissioning software, see manual of out-
door station )
Connect the outdoor station (AS=1) to the input S1.
Connect the outdoor station (AS=2) to the input S2.
Assign the unused inputs with " Input unused"
Programming
Programming with the service device TK SERVICE
Assign and lock all AS addresses of the out door stations
Assign the bell buttons of the out door stations with the serial no. of the respective
indoor station
Assign the camera inputs S1, S2, S3 and S4 of the TK VU4 REG to the respective
AS-addresses with the function "Connect camera input with video outdoor station", if
factory settings have to changed.
Assign unused camera input
NOTE: First assign and lock the AS-addresses of the video outdoor station.
Connect camera input with video outdoor station
Assign unused camera input
NOTE: Camera input 1 cannot be assigned as "unused".
TK VU 4 REG - Load factory settings
Ser.-Nr.M = Seriial number ofr TK VU4 REG
K = Number of the camera input of TK VU4 REG (= 1 ... 4)
AS = AS-address of outdoor stations for this camera input (= 0 ... 63)
Programming with the commissioning software TK-IBS-TOOL
Assign and lock all AS addresses of the out door stations
Assign the bell buttons of the out door stations with the serial no. of the respective
indoor station
Assign the camera inputs S1, S2, S3 and S4 of the TK VU4 REG to the respective
AS-addresses.
Select for unused camera inputs: Input unused
7
Acceptance of guarantee
We accept the guarantee in accordance with the corresponding legal provisions.
Please return the unit postage paid to our central service department giving
a brief description of the fault:
ALBRECHT JUNG GMBH & CO. KG
Service-Centre
Kupferstr. 17-19
44532 Lünen
Germany
Service-Line: 0 23 55 . 80 65 51
Telefax: 0 23 55 . 80 61 89
Technique (DCM)
Service-Line: 0 23 55 . 80 65 52
Fax: 0 23 55 . 80 62 55
Albrecht Jung GmbH & Co. KG
P.O. Box 1320
58569 Schalksmühle
Germany
http://gb.jung.de/
www.jung-catalogue.com
The
-sign is a free trade sign addressed
exclusively to the authorities and does not
include any warranty of any properties.
Technical subjects to change.
EN_TK_VU4_REG.doc
05/201010
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

JUNG TKVU4 Operating instructions