Whirlpool AKR 631 IX WP Program Chart

Category
Cooker hoods
Type
Program Chart

This manual is also suitable for

Whirlpool AKR 631 IX WP is a cooker hood designed to effectively remove smoke, steam, and odors from your kitchen. It features three speed settings, allowing you to adjust the extraction power based on your cooking needs. The hood also comes with halogen bulbs for efficient lighting while you cook. Additionally, the grease filter can be easily removed and cleaned to maintain optimal performance.

Whirlpool AKR 631 IX WP is a cooker hood designed to effectively remove smoke, steam, and odors from your kitchen. It features three speed settings, allowing you to adjust the extraction power based on your cooking needs. The hood also comes with halogen bulbs for efficient lighting while you cook. Additionally, the grease filter can be easily removed and cleaned to maintain optimal performance.

5019 318
33110
AKR 631 - AKR 948 - AKR 952
INSTALLATIONSANGABEN
Mindestabstand zur Kochfläche: 50 cm (Elektroplatten), 75 cm (Gas-, Öl-,
Kohlekochplatten). Folgen Sie bei der Installation der Nummerierung (1
Ö
2
Ö
3
Ö
.....).
Schließen Sie das Gerät erst nach erfolgter Installation an die Stromversorgung an.
Achtung! Das Auslassrohr und die Befestigungsmanschetten (15) sind nicht im
Lieferumfang inbegriffen und müssen gesondert erworben werden.
INSTALLATION SHEET
Minimum height above cooker: 50 cm (electric cookers), 75 cm (gas, gas oil or coal
cookers). To install follow points (1
Ö
2
Ö
3
Ö
.....). Do not connect the appliance to the
electrical power supply until installation is completed. Warning! The exhaust pipe and
clamps (15) are not supplied and must be bought separately.
FICHE D'INSTALLATION
Distance minimale par rapport à la cuisinière : 50 cm (cuisinière électrique), 75 cm
(cuisinière à gaz, mazout ou charbon). Pour le montage, suivez la numérotation
(1
Ö
2
Ö
3
Ö
.....). Ne branchez pas l'appareil tant que l'installation n'est pas terminée.
Attention ! Le conduit d'évacuation et les colliers de fixation (15) ne sont pas fournis
et doivent être achetés à part.
INSTALLATIEKAART
Minimumafstand tot het kooktoestel: 50 cm (elektrische kooktoestellen), 75 cm
(kooktoestellen op gas, olie of kolen). Volg voor de montage de nummering
(1
Ö
2
Ö
3
Ö
.....). Geef het apparaat geen stroom totdat de installatie geheel voltooid is.
Let op de afvoerbuis en de klembanden (15) worden niet bijgeleverd en moeten apart
worden aangeschaft.
FICHA DE INSTALACIÓN
Distancia mínima desde los quemadores: 50 cm (fuegos eléctricos), 75 cm (fuegos de
gas, gasóleo o carbón). Para el montaje, siga la numeración (1
Ö
2
Ö
3
Ö
...). No conecte
el aparato a la corriente eléctrica hasta que la instalación esté completamente
finalizada. ¡Atención! El tubo de descarga y las abrazaderas (15) no están incluidas y
se compran aparte.
FICHA DE INSTALAÇÃO
Distância mínima dos fogões: 50 cm (fogões eléctricos), 75 cm (fogões a gás, óleo ou
carbono). Para montar siga a numeração (1
Ö
2
Ö
3
Ö
.....). Não ligue o aparelho à
corrente eléctrica até a instalação estar concluída. Atenção! O tubo de descarga e as
tiras de fixação (15) não são fornecidas e devem ser compradas à parte.
SCHEDA INSTALLAZIONE
Distanza minima dai fuochi: 50 cm (fuochi elettrici), 75 cm (fuochi a gas, gasolio o
carbone). Per il montaggio seguire la numerazione (1
Ö
2
Ö
3
Ö
.....). Non dare corrente
all’apparecchio finché l’installazione non è totalmente completata. Attenzione! Il tubo
di scarico e le fascette di fissaggio (15) non sono fornite e vanno acquistate a parte.
ùüùü+ùùùþ
ü$12.)12.1.)2"0120"FP02!"0120"FP0120"
.0! #02!0. #0! # +.22  21.  #1202
.!1
1
Ö
2
Ö
3
Ö
2! 3 / 2020002!)!0*.21#10#!
2  !&12"0.212.1"! 1 $1&."..&".2.
 !.120!&1"/0/.202..!0.. 2 *$&!12
D
GB
F
NL
E
P
I
GR
31833110.fm Page 1 Friday, December 19, 2003 9:54 AM
5019 318
33110
AKR 631 - AKR 948 - AKR 952
AKR 952
31833110.fm Page 2 Friday, December 19, 2003 9:54 AM
5019 318
33110
AKR 631 - AKR 948 - AKR 952
Preliminary information for installing the hood:
Disconnect the power supply at the domestic main switch before carrying out electrical connections.
1.
Place the extraction unit on a flat surface and fit the bottom part of the hood on it
(remove the grease filter/s).
2.
Carry out the electrical connections between the two parts.
3.
Fix the hood to the extraction unit with 10 screws.
4.
Using a pencil, draw the centre line on the wall up to the ceiling to facilitate installation operations.
5.
Attach the hole diagram to the wall: the vertical centre line printed on the hole diagram must match the
centre line drawn on the wall, and the lower edge of the hole diagram must match the lower edge of the
hood: remember that with installation completed the bottom of the hood must be at least 50 cm above the
cooktop in case of electric cookers and 75 cm in case of gas or mixed cookers.
6.
Place the support bracket on the hole diagram so that it matches the dashed rectangle, mark the two
external holes and drill, remove the hole diagram, insert 2 wall plugs and fix the hood support bracket with
two 5x45 mm screws.
7.
Hook the hood to the bracket.
8.
Adjust the distance between the hood and the wall.
9.
Adjust the hood horizontally.
10.
From the inside of the hood, mark the two holes for fixing the hood.
11.
Remove the hood from the bracket.
12.
Drill on the marks (Ø 8 mm - see step 10).
13.
Insert 2 wall plugs.
14.
Fit the flue support bracket
G
to the wall and against the ceiling, use the support bracket as hole diagram
(the small slot on the support must match the line drawn on the wall - step 4) and mark 2 holes with the
pencil, drill the holes (Ø 8 mm), and finally insert 2 plugs.
15.
Fix the flue support bracket to the wall with two 5x45 mm screws.
16.
Hook the hood to the bottom bracket.
17.
Fix the hood with two 5x45 mm screws (ABSOLUTELY NECESSARY).
18.
Connect an exhaust pipe (pipe and clamps are not supplied and must be bought separately) to the collar
B
located above the extraction motor unit.
For extractor operation, connect the other end of the exhaust pipe to the home discharge device. For filter
operation, fix the deflector
F
to the flue support bracket
G
(model
AKR 948-631
with 4 screws - model
AKR 952
with 2 screws) and connect the other end of the exhaust pipe to the deflector collar
F
(if the
collar is not already fitted it should be inserted on the deflector and secured with 1 screw). Once the steam
and fumes have been filtered by the carbon filter (not provided, to be ordered separately) they are
conveyed back to the kitchen through grid
H
.
19.
Carry out the electrical connection.
20.
Apply the flues and fix them with 2 screws (
20a
) to the flue support
G
(
20b
).
21.
Slide the bottom section of the flue in the special seat above the hood to completely cover the extraction
unit.
22.
(model
AKR 952
only): fix the bottom section of the flue to the hood with two 3x9 screws.
Refit the grease filter/s and check for correct hood operation.
INSTALLATION - ASSEMBLY INSTRUCTIONS
D F NL E
GB
P I GR
31833110.fm Page 5 Friday, December 19, 2003 9:54 AM
5019 318
33110
AKR 631 - AKR 948 - AKR 952
D F NL E
GB
P I GR
1.
Control panel.
2.
Grease filter.
3.
Halogen bulbs.
4.
Steam deflector.
5.
Telescopic flue.
To clean the grease filter
Wash the grease filter at least once a month.
1.
Disconnect the electrical power supply.
2.
Remove the grease filters -
Fig. 2
: pull the spring
release handle
(f)
downwards, then remove the
filter.
3.
After cleaning the grease filter refit in reverse
order, making sure the entire extraction surface is
covered.
Carbon filter Fitting and Maintenance
Fitting the carbon filter:
1.
Disconnect the electrical power supply.
2.
Remove the grease filter
(f - Fig. 2)
.
3.
Turn the side knobs 90° and then remove the
filter holder
(g - Fig. 3)
.
4.
Fit the carbon filter
(h - Fig. 3)
in the filter holder
(i - Fig. 3)
.
5.
Refit the filter holder and secure it to the hood
with the screw
(g - Fig. 3)
.
6.
Refit the grease filter.
Carbon filter maintenance:
Unlike traditional carbon filters, this carbon filter can
be washed and reactivated.
With normal hood use, the filter should be cleaned
once a month. The best way to clean the filter is in a
dishwasher at the highest temperature possible, using
a normal dishwasher detergent. To avoid particles of
food or dirt settling on the filter during washing and
giving rise to unpleasant smells, it is advisable to wash
the filter on its own. After washing, dry the filter in the
oven at 100° C for 10 minutes to reactivate it.
The filter will retain its odour-absorbing capacity for
three years, after which it must be replaced.
Replacing bulbs
1.
Disconnect the electrical power supply.
2.
Use a small screwdriver or any other suitable tool
to prise off
(m-Fig. 4)
the lamp cover
(p-Fig. 4)
.
3.
Remove the burnt-out bulb.
Replace using 20 W max halogen bulbs only,
making sure not to touch them with your hands.
4.
Close the lighting unit (snap-close).
CONTROL PANEL
A.
Light ON/OFF switch.
B.
ON/OFF and speed 1 selector switch
(small amount of steam and fumes).
B+D.
Speed 2 selector switch
(medium amount of steam and fumes).
B+D.
Speed 3 selector switch
(large amount of steam and fumes).
Fig. 1
Fig. 4
Fig. 2
Fig. 3
PRODUCT SHEET
31833110.fm Page 6 Friday, December 19, 2003 9:54 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Whirlpool AKR 631 IX WP Program Chart

Category
Cooker hoods
Type
Program Chart
This manual is also suitable for

Whirlpool AKR 631 IX WP is a cooker hood designed to effectively remove smoke, steam, and odors from your kitchen. It features three speed settings, allowing you to adjust the extraction power based on your cooking needs. The hood also comes with halogen bulbs for efficient lighting while you cook. Additionally, the grease filter can be easily removed and cleaned to maintain optimal performance.

Ask a question and I''ll find the answer in the document