CAME AGATAKIT/X1-DVC Installation guide

Category
Soundbar speakers
Type
Installation guide
VA/01
AGATA V-VC
AGATA VC/B DVC/01 ME
INSTALLATION MANUAL
AGATAKIT VC01
AGATAKIT VCB01
AGATAKIT V01
EN
English
FB00952-EN
VIDEO ENTRY KIT
1
2
A B C D
A
B
Page 2 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
General Precautions
Read the instructions carefully before beginning the installa-
tion and carry out the actions as specified by the manufacturer.
The installation, programming, commissioning and mainte-
nance of the product must be carried out only by qualified tech-
nical personnel, correctly trained with regard to respecting the
regulations in force, including the implementation of accident
prevention measures.
Before carrying out any cleaning or maintenance operation,
disconnect the power supply.
The equipment must be destined only for the use for which
it was designed.
The manufacturer declines all liability for any damage as a
result of improper, incorrect or unreasonable use.
This product complies with the relevant directives in force.
Decommissioning and disposal. Dispose of the packaging
and the device at the end of its life cycle responsibly, in com-
pliance with the laws in force in the country where the product
is used. The recyclable components are marked with a symbol
and the material's ID marker.
THE DATA AND INFORMATION SHOWN IN THIS MANUAL ARE TO BE
CONSIDERED AS SUBJECT TO CHANGE AT ANY TIME AND WITHOUT
THE NEED FOR ANY ADVANCE WARNING. MEASUREMENTS, UNLESS
OTHERWISE INDICATED, ARE IN MILLIMETRES.
AGATA VC-V/AGATA VC B
Wall-mounted installation
Remove the unit from the metallic support by sliding it after pres-
sing the plastic button A.
Attach the wall bracket to the round recessed box Ø 60mm B
A, the rectangular box 503 (B B and C), the rectangular
box 506E B 4, or the Ophera recessed box (PHI) using the
provided screws and observing the TOP indication. To ensure
greater stability to the mounting surface, secure box with screws
and anchors provided.
The recessed box must be fitted at a suitable height in relation
to the user. Avoid excessive tightening of the screws. Once the
connections have been made, hook the video terminal to the me-
tal support C D.
C
D
E
F
– + B
CL.RES
M/S
M1
Agata V - Agata VC
Page 3 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
To release the unit from the metal support, press the plastic hook
and lift the terminal E.
Technical data
Type AGATA VC-V
AGATA VCB
Power supply by BUS (VDC) 15 - 20
Max. consumption (mA) 175
Consumption in stand-by mode (mA) <1
Single LED consumption (mA) 1
Storage temperature (°C) -25 to +70
Operating temperature (°C)
+5 to +40
IP Rating IP 30
Video standard PAL/NTSC
LCD TFT display (inches) 3.5
Closing resistance (CL.RES)
Master/Slave selector (M/S)
M/S MASTER SLAVEM/S
Fam. Rossi
In case of simultaneous call, the audio/video communication
will be activated on the MASTER extension only.
Function of terminals
Terminal board M1 F
Agata VC-V
BBUS line input
+ Doorbell
– +
AL B
CL.RES
M/S
M1
G
H
Agata VC/B
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
3sec
... beep!
A
B
C
E
F
HI
G
D
Page 4 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Terminal board M1 G
Agata VC/B
BBUS line input
+ Doorbell
AL Alarm input
Configuring melodies H
Perform each of the following programming-steps, in
succession.
1-Enter programming mode.
Press and keep pressed the button for three seconds. A buz-
zing sound and a flashing LED confirm that you have entered the
programming mode A.
2-Programming the melody associated to the call from the
entry panel.
To listen to the melodies in sequence, press button B.
To select the melody and exit the programming mode, press but-
ton C.
To select the melody and continue in programming mode, press
button D.
3- Programming the melody associated to a call from the
landing.
To listen to melodies in sequence, press button E.
To select the melody and exit the programming mode, press but-
ton F.
To select the melody and continue in programming mode, press
button G.
4-Programming the number of rings per call.
Press the button as many times as the number of rings you
want (from 1 to 6 rings) H.
After three seconds from the last pressing of a button, the call
will be made with the number of selected rings.
To exit the programming mode, press button I.
To program a call, see the literature for entry panels.
43,5
45
7,5 57
210
106
A
B
64,5
210
145
2
1
3
A
B
C
Page 5 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
VA/01
Installation
The power supplier must ALWAYS be installed horizontally.
The device can be installed on a DIN rail (EN 50022) in an ap-
propriate electric panel or it may be wall-mounted using the pro-
tective terminal covers.
For disassembly, proceed as shown in figure B-C.
For the overall dimensions see figure A.
NOTE. Proper ventilation is required if the power supplier is
installed in a metal container.
Technical data
Type VA/01
Power supply [VAC] 230
Max current demand [AAC] 0,35
Max energy dissipation [W] 25
Entry panels nominal power supply [VDC] 18
Entry panels current demand [A] 0,6
Entry panels peak power supply [VDC] 18
Entry panels peak current demand [A] 1,1 <15’’ (*)
Rising cable power supply [VDC] 20
Rising cable current demand [A] 0.8 for 1’
Rising cable current demand [A] 0.2 for 3’
Dimensions [DIN] 12
Storage temperature [°C] -25 ÷ + 70
Operating temperature [°C] 0 ÷ +35
Protection rating [IP] 30
(*) 1.6 A <15’’ with rising cable not connected or connected
separately.
MINI
USB
RS232 PROG
DL2 DL1
RFID
PROG
+
Ð
+12V
BIN1 BIN2 BIN3 BOUT
M1
A
D
1BC
D
Page 6 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Functions D
Terminal boards A
~Mains
~
Morsettiera M1
Aux 1 output Open Collector max 100 mA
+12V Common
Aux 2 output Open Collector max 100 mA
+ Entry panel power supply 18 VDC (*)
BIN1 BUS line input from entry panel 1
BIN2 BUS line input from entry panel 2
BIN3 BUS line input from entry panel 3
BOUT Busbar output
(*) The appliance is electronically protected against overloads
and short circuits.
Connectors
A RS232: Reserved for future use
B MINI USB: Connector for programming from a PC
C PROG button (**)
RFID PROG Jumper (**)
RFID
PROG
+
Ð
M1
A
RFID
PROG
+
Ð
M1
A
RFID
PROG
+
Ð
M1
A
Default Code entry Code deletion
LED
Colour Meaning
DL1 (**) Yellow Programming status
DL2 Green USB connected
(**) Refer to the “Programming".
VA/01
VA/01 VA/01
VA/01
VA/01
VA/01
VA/01
VA/01
VA/01 VA/01
VA/01
VA/01
VA/01 VA/01 VA/01
VA/01
130+320+500=950 mA <1100 mA 500+130+320+500=1450 mA >1100 mA
500 mA 500 mA 500 mA
320 mA 320 mA
130 mA 130 mA
35+35+35+130+130+35+130+35+35+35=635 mA >600 mA
130 mA 130 mA 130 mA35 mA 35 mA 35 mA 35 mA 35 mA 35 mA 35 mA
35+35+130+130+35+130+35+35=565 mA <600 mA
130 mA 130 mA 130 mA35 mA 35 mA 35 mA 35 mA 35 mA
Page 7 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Absorption
With entry panel ‘on standby’ With solenoid lock ‘on’ With surveillance camera on
130 mA 130 mA 35 mA 320 mA 500 mA
A
B
C
A
B
D
E
500 mm
1190 mm
100°
870 mm
500 mm
50 mm
180 mm
65 mm
82°
F
1
B
Page 8 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
DVC/01 ME
Wall mounting
fix the given plugs and screw the entry panel A at the desired
height considering the position of the lens of the camera B.
Run the hose with the system conductors as shown in figure A.
Extract the plastic terminal cover and wire the connections C.
WARNING. The connection cables must be unsheathed flush
with the wall and inserted as indicated in figure D (the
cables coming from the power supplier to the left and those
regarding service functions to the right).
Once all the connections have been made, re-insert the terminal
covers.
Perform the programming and adjustment operations of the entry
panel as described to the chapter “Programming”.
2
1
2
1
1
2
G
H
I
CN4
CN1
CN1
CN2
J K
Page 9 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Recessed installation
Install the recessed box at the desired height considering the
position of the lens of the camera B, but in advance, run the
hose with the system conductors through one of the breaking
points E1. During installation of the recessed box it is possible
to avoid any deformation by using the provided spacer E2.
To facilitate the connections, lay the frame on the built-in box F.
Introduce the cable connections in the special hole and lay the
entry panel on the frame as shown in figure F and fix it in a
semi-extract position G; extract the plastic terminal cover and
wire the connections.
WARNING. The connection cables must be inserted as in-
dicated in figure D (the cables coming from the power
supplier to the left and those regarding service functions
to the right).
Once the connections have been made bring into contact, by
gently pushing upwards, the entry panel and the frame H and
re-insert the terminal covers G.
Perform the programming and adjustment operations of the entry
panel as described to the chapter “Programming”.
Side-by-side wall installation
Entry panels can be placed side-by-side both horizontally and
vertically.
Using a cutter, remove the plastic details of the entry panel bases
I.
Run the connection wires between the entry panel bases J,
ensuring to follow the sequence indicated in figure K and L.
A
CN4
CN1
CN2
CN1
M
O
L
1
2
N
Page 10 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Side-by-side recessed installation
Entry panels can be placed side-by-side both horizontally and
vertically M locking the boxes with one another.
Before installing them, break the lower and side breaking points
as highlighted in figure M in order to run the connection cable
from the push button entry panel to the main/previous entry
panel.
Using a cutter, remove the plastic details of the entry panel ba-
ses N.
Run the connection wires between i the entry panel bases ensu-
ring to follow the sequence indicated in figure O.
P1
B
C
D
E
7
F
H
I
J
254
99 25
281
127
1,2
Q
Page 11 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Accessories P
1 Single height button DPS;
2 Double height button DPH;
3 Double DPD button;
4 Single height plu DTS ME;
E Double height stopper DTH ME;
F Access control module with keyboard DNA ME;
G Access control module with RFID reader DRFID,
8 Recessed box DSI;
9 Recessed frame DCI ME,
J Wall roof DTP
Technical data
Type DVC/01ME
Power supply (VDC) 14-18
Absorption (mA) 320
Consumption in stand-by mode (mA) 130
Storage temperature (°C) -25 ÷ + 70
Operating temperature (°C) -15°C +50°C
IP Degree 54
Standard video PAL/NTSC
Resolution (pixel) 680x512
Minimum lighting (LUX) 1
M1
CN4
M2
CN2
DATI
MINI USB
OUT
BOUT
PROG
65
2
G
3
4
1
R
M1
M2
M5
+12V
+12V
BIN1 BIN2 BIN3 BOUT
PROG
M1
CN4
M2
CN2
DATI
MINI USB
OUT
VLS/300
B
B
NO
C
+
BOUT
CN1
IN
Page 12 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Functions R
Terminal boards 1
+Power supply
14-18 VDC
BOUT Riser
Terminal boards 2
Solenoid lock
12 V - 1 A max
Door lock release button (NA)
Door contact input (NC)
Ground
Entry panel enabling output (active towards earth)
Ground
Connectors
3 CN2: Connector for the keyboard or RFID access control
module.
4 CN4: Additional push button panel connector.
5 MINI USB: Programming connector.
For the manual programming of the entry panels, the
self-connection order is BIN1-BIN2-BIN3.
Adjustments 6
loudspeaker audio
microphone audio
solenoid lock 1-10 s. (default 1 s)
Signals G
Red - Call in progress
Green - Door open
Yellow - Conversation in progress
Blue - System busy
111
12
13
14
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
1
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
1
7
8
6
5
2
3
4
7
8
9
10
11
12
13
14
111
12
13
14
10
9
8
7
6
5
2
3
4
1
1
27
5
4
3
1
6
2
3
4
3
5
7 8
6
4
2
1
3
5
7 8
6
4
2
Page 13 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Manual programming of entry panels
It is possible to programme only one or several audio/video entry
panels that have the same calls (unless "blind units" are used
that disable one or more of them).
It is possible to programme entry panels (connected to the same
power supply) with dierent types of keys, still respecting the
sequence shown on the left.
It is not possible to pro-
gramme entry panels with
dierent types of keys.
Programming with PC soft-
ware removes all of the re-
strictions just outlined.
M1
A
PROGPROG
>3’
1
33 A
D
3 B
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
3 C
y
E
F
beep
M1
A
PROGPROG
78
<1’
2
Page 14 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
PROGRAMMING ENTRY PANELS
First Programming with ONE entry panel
Entering Programming Mode. Press the PROG key on the power supply 1 until the
PROG LED lights up. If the PROG LED immediately goes out, this indicates a malfunction
in the connections between the power supply and the entry panel. Check the connec-
tions and return to programming. The LEDS on the entry panels light up as shown in fig-
ure 2. Wait 5 seconds for the auto test to be completed and continue as shown below.
Programming Type of Keys. Press the first key on the entry panel 3/3A/3B until
the LED stops flashing along with the backlighting LEDs 4.
Programming the call keys. Lift the receiver (if present) of the extension that you want
to programme then press the door lock release and AUX2 5 buttons. On the
entry panel, press the call key to associate with the internal extension 6: an acoustic
signal will confirm that the setting was stored. Hang up the receiver again, if necessary
h and continue, repeating the same operations for the other extensions.
Exiting Programming. Briefly press the PROG key on the power supply 7: the PROG
LED and the LEDs on the entry panels will go out. NOTE. If no action is performed, the
procedure will end automatically after 30 minutes.
Programming entry panel video cameras. While programming the call keys the
"visual range" of the video camera can be adjusted from any receiver (with handset
raised, it there is one), by pressing on the "Self-connection" key 8.
Should call keys be present ONLY ON ADDITIONAL BUTTON PANELS, the opera-
tion shown in figure 3 is carried out on these as shown in figure 3C.
3
8
4
6
9
7
5
2
1
100 °
82 °
54 °
72 °
1÷9
0
9
J
M1
A
PROGPROG
>3’
1
2
3
4
56
Page 15 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
From the default settings it is possible to scroll through the following ones I by press-
ing the AUX1 key or to go back to the previous ones with the AUX2 key J: the
setting is saved automatically.
Entry panel brightness level adjustment. While programming the call keys the entry
panel brightness level can be adjusted from any receiver. Pressing the "Self-connec-
tion" key on the receiver causes the video camera of the entry panel for which the
brightness level is to be adjusted to be activated. The brightness level can be increased/
decreased by using a previously assigned call key, or by simulating a call from DNA.
First Programming with SEVERAL entry panels
Entering Programming Mode. Press the PROG key on the power supply 1 until the
PROG LED lights up. If the PROG LED immediately goes out, this indicates a malfunction
in the connections between the power supply and the entry panel. Check the connec-
tions and return to programming. The LEDS on the entry panels light up as shown in fig-
ure 2. Wait 5 seconds for the auto test to be completed and continue as shown below.
Programming Type of Keys. Press the first key on the entry
panel 3 until the LED stops flashing along with the back-
lighting LEDs 4. Repeat this operation for all the entry panels
to be programmed 4 5: at the end the signals will have this
configuration 6.
- Should call keys be present ONLY ON ADDITIONAL BUTTON
PANELS, proceed as shown in the NOTE on page 14.
7
8
beep
2
M1
A
PROGPROG
>3’
1
3
4
beep
Page 16 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Programming the call keys. Lift the receiver (if present) of the extension that you want
to programme then press the door lock release and AUX2 7 buttons. On the
entry panel, press the call key to associate with the internal extension 8: an acoustic
signal will confirm that the setting was stored. Hang up the receiver again, if necessary
and continue, repeating the same operations for the other extensions. The operation
may only be performed from the entry panel with the LED o (PE1 in fig. 6): to
change the entry panel from which the call programming is performed, press one of
the first 4 call key positions for at least 3s (or press key 1 followed by key for entry.
panels with DNA).
Exiting Programming. Briefly press the PROG key on the power supply: the PROG LEDs and the LEDs on the entry panels will go out.
NOTE. If no action is performed, the procedure will end automatically after 30 minutes.
Programming entry panel video cameras. While programming the call keys the "visual range" of the video camera can be adjusted
in the way already described.
Entry panel brightness level adjustment. While programming the call keys the entry panel brightness level can be adjusted in the
way already described.
Reprogramming Procedure
Entering Programming Mode. Press the PROG key on the power supply 1 until the
PROG LED lights up. The LEDS on the entry panels light up as shown in figure 2. Wait
5 seconds for the auto test to be completed and continue as shown below.
Programming the call keys. Lift the receiver (if present) of the
extension that you want to programme then press the door lock
release and AUX2 3 buttons. On the entry panel, press
the call key to be associated with the internal extension 4: an
acoustic signal will confirm that the setting was stored. Hang
up the receiver again, if necessary and continue, repeating the
same operations for the other extensions.
The operation may only be performed from the entry panel with
the LED o (PE1 in 2): to change the entry panel from which
call programming is performed, press one of the first 4 call key
positions for at least 3s (or press key 1 followed by key for
entry. panels with DNA).
M1
A
PROGPROG
<1’
5
M1
A
PROGPROG
>3’
6
7
H
I
J
M1
A
PROGPROG
>3’
K
Page 17 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Exiting Programming. Briefly press the PROG key on the power supply 5: the PROG
LEDs and the LEDs on the entry panels will go out. If no action is performed, the proce-
dure will end automatically after 30 minutes.
Programming Type of Keys. In “Programming Call Keys" 6 press and hold down the
PROG key of the power supply until you go into the "Programming Type of Keys” pro-
cedure 7. Press one of the first 4 "keys" on the entry panels to be reprogrammed, the
LED will stop flashing, as will the backlighting LEDs of the first 4 positions of the call
keys 8. Repeat this operation on all the entry panels to be reprogrammed 8 and I.
If all the entry panels are reprogrammed, the configuration will
be as shown in figure J. To exit reprogramming, briefly press
the PROG key on the power supply K: the PROG LEDs and the
LEDs on the entry panels will go out. If no action is performed,
the procedure will end automatically after 30 minutes.
Programming entry panel video cameras. While program-
ming the call keys the "visual range" of the video camera can be
adjusted in the way already described.
Entry panel brightness level adjustment. While programming
the call keys the entry panel brightness level can be adjusted in
the way already described.
Should call keys be present ONLY ON ADDITIONAL BUTTON
PANELS, proceed as shown in the NOTE on page 14.
WARNING. If an entry panel is added, replaced or moved,
the modifications are acquired by going into "Programming
Type of Keys" (from figure 6-K).
2
45
XX beep
+
6
M1
A
PROGPROG
>3’
1
M1
A
PROGPROG
>3’
3
Page 18 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Programming with DNA
1
2
3
4
5
6
7
8
9
10
For this type of configuration of Entry
panels refer to the procedures already
described.
For this type of configuration of Entry panels refer
to the procedures described below.
Entering Programming Mode. Press the PROG key on the power supply for more than
3 seconds 1. The LEDS on the entry panels light up as shown in figure 2. If the PROG
LED immediately goes out, this indicates a malfunction in the connections between the
power supply and the entry panel.
Check the connections and return to programming. Repeat the
operation 3 a second time. Check that the configuration on the
Entry panels is as shown in figure 4. Wait 5 seconds for the
auto test to be completed and continue as shown below.
Programming the call codes. Lift the receiver (if present) of the extension that you
want to programme e then press the door lock release and AUX2 5 buttons.
Enter the call code for the group (1 to 99) and then press F to associate the code
key with the internal extension. Hang up the receiver again, if necessary h and continue,
repeating the same operations for the other extensions. The operation may only be per-
formed from the entry panel with the LED o (PE1 in 4): to change the entry panel
from which call programming press key 1 followed by key .
Exiting Programming. Briefly press the PROG key on the power supply: the PROG
LEDs and the LEDs on the entry panels will go out. NOTE. If no action is performed, the
procedure will end automatically after 30 minutes.
RFID
PROG
+
ÐM1
A
PROG
1
2
RFID
PROG
+
ÐM1
A
PROG
RFID
PROG
+
ÐM1
A
PROG
1
2 4
beep
3
12345
12345
+ +
5beep
6
7
beep
+
Page 19 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Entering Codes and Tags
Position the power supply's PROG RFID jumper at “+” 1: the power supply's PROG
LED will flash slowly along with the message LEDs with the configuration in fig. 2. If
the LEDs immediately go out it means there is a malfunction in the connections between
the power supply and entry panel. Check the connections and return to programming.
Badge. Bring a badge/tag up to the reader of any entry panel
that has already been addressed 3 and, after the confirmation
beep, press the key (group) to which the code should be as-
signed 4. If the maximum permitted number is exceeded (5)
for each group, an error tone will be generated.
Codes. Press , enter the access code (4-8 figures) followed by the key on the
keypad of any already addressed entry panel reader 5 and, after the confirmation
beep, enter the call code for the group and then press 6 (or press the group key).
If the maximum permitted number is exceeded (5) for each group, an error tone will be
generated.
Finally, reposition the PROG RFID jumper in the rest position 7: the procedure is
NOT terminated automatically!
Deleting Codes and Tags
Position the power supply's PROG RFID jumper at “–” 1: the power supply's PROG LED
will flash slowly, along with the message LEDs with the configuration in fig. 2. If the
LEDs immediately go out it means there is a malfunction in the connections between the
power supply and the entry panel. Check the connections and return to programming.
beep beep
3 4
12345
+ +
5beep
>10’
>1’
beep
beep
6
7
12345 12345
beep beep
+ +
8 9
M2 M3
PROG
RFID
PROG
+
Ð
J
Page 20 - Manual FB00952-EN - vers. 1 - 12/2017- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Badge. Bring a badge/tag up to the
reader of any entry panel that has already
been addressed 3 and, after the confir-
mation beep, repeat this once again to
confirm 4: ALL the badges relating to
the GROUP will be deleted.
Codes. Press , enter the access code (4-8 figures) followed
by the key on the keypad of any entry panel that has already
been addressed 5 and, after the confirmation beep, repeat this
once again to confirm: ALL the codes relating to the GROUP will
be deleted.
Badges and Codes. Entry panels with buttons: hold down for at least 10 seconds the
call key 6 relating to the GROUP for which the codes are to be deleted and, after the
beep, press the key again (briefly) 7. In this way ALL the GROUP's codes and badges
of any type will be deleted.
Entry panels with DNA. Enter the call code followed by the 8 key related to the
GROUP for which the codes are to be deleted and, after the beep, enter the call code
again followed by the key 9. In this way ALL the GROUP's codes of any type will
be deleted.
Finally, reposition the PROG RFID jumper in the rest position J: the procedure is
NOT terminated automatically!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

CAME AGATAKIT/X1-DVC Installation guide

Category
Soundbar speakers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI