PROG key 3and PROG LED 4
Programming key and LED (see 'Programming' paragraph).
The PROG LED can be in the following conditions:
O
On
Flashing slowly
Flashing quickly
Adjustments 5
Speaker audio
microphone audio
solenoid lock 1÷10 s. (default 1 s)
JUMPER
6 SW3: Enabling/disabling intercom function (see
'Programming' paragraph).
Technical features
Type LVC/01 LC/01
Power supply (VDC) 16÷18
Consumption (mA max) 250 120
Consumption in stand-by mode
(mA) 100 75
Dimensions (mm) 99x207x30
Storage temperature (°C)* -25 to +70
Operating temperature (°C) -15 to +50
IP Rating 54
Video standard PAL/NTSC -
Resolution (pixel) 680x12 -
Minimum lighting (LUX) 1 -
Average life (hours)** 90,000
Functions
Terminal board 1
BOUT Busbar
+16-18 VDC power supply
Terminal board 2
Earth
Door release button (NA)
Solenoid lock
12 V - 1 A max
General precautions
Important safety instructions: READ CAREFULLY! • Installation, programming, commissioning and maintenance must
only be carried out by expert qualifi ed technicians in full compliance with the regulations in force. • Wear anti-static shoes
and clothing if working on the electronic circuit board. • Keep this precaution information. • Disconnect the power supply
during any cleaning or maintenance work.The product must only be used for the purpose for which it was expressly
designed. Any other use is to be considered dangerous.The manufacturer declines all liability for any damage as a result
of improper, incorrect or unreasonable use.The product, in its original packaging supplied by the manufacturer, must
only be transported in a closed environment (railway carriage, containers, closed vehicles). •If the product malfunctions,
stop using it and contact customer services at https://www.came.com/global/en/contact-us or via the telephone
number on the website.
The manufacture date is provided in the production batch printed on the product label. If necessary, contact us at
https://www.came.com/global/en/contact-us.
The general conditions of sale are given in the o cial CAME price lists.
V
BIN1 BIN2 BIN3 BOUT
M1
BOUT
M2
VLS/300
B
B
NO
C
+
M1
BOUT
M2
M2M1
+
VLS/300
B
B
NO
C
+
VAS/100
VA/01
Page 3 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 3 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Connection examples
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very
high or very low temperature.
(**) The average product life is a purely indicative estimate. It applies to compliant usage, installation and maintenance
conditions. It is also infl uenced by other factors, such as climatic and environmental conditions.
1
1
E
G
F
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
>3’
>3’
<6’
<6’
B
OUT
PROG
PROG
B
OUT
PROG
PROG
P
P
M1
BOUT
PROG
M1
BOUT
PROG
3
3A
3 B
4
4
beep
beep
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
<1’
<1’
2
2
Page 4 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 4 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Continue, repeating the same operations for all the other
receivers.
Exiting Programming
Press the PROG key briefl y: the PROG LED switches o G.
If no action is performed, the procedure will end automatically after 30
minutes.
Programming call keys
Press the door release and AUX2
buttons at the same time 5.
On the entry panel, press the call key
to be linked to the receiver 6: a beep
will confi rm that the setting has been
stored.
Entering programming mode
Press the PROG key for at least 3 seconds 1 and then release it (within 6
seconds), as soon as the PROG LED lights up and the key back lighting fl ashes
as illustrated in fi gure 2.
PROGRAMMING ENTRY PANELS WITH VAS/101
Programming for the first time
Programming Type of Keys
Hold down the fi rst key on the entry panel in the position shown C/CACB
until the back lighting LEDs stop fl ashing 4 and stay on.
C
C
E
4
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
>3’
>3’
<6’
<6’
B
OUT
PROG
PROG
P
2
2
beep
beep
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
<1’
<1’
F
F
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
>3’
>3’
<6’
<6’
B
OUT
PROG
PROG
P
G
G
M1
BOUT
PROG
8
8
9
9
1
1
Page 5 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 5 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Continue, repeating the same operations for all the other receivers.
Exiting Programming
Press the PROG button briefl y E. The PROG LED switches o .
If no action is performed, the procedure will end automatically after 30
minutes.
Programming Type of Keys
In "Programming Call Keys", press the PROG key for at least 3 seconds F and
then release it (within 6 seconds) as soon as the PROG LED lights up and the
key back lighting fl ashes as illustrated in fi gure G, entering "Programming
Type of Keys".
Press the fi rst key on the entry panel in the position shown 8 until the back
lighting LEDs stop fl ashing I and stay on.
At the end, to exit programming, briefl y press the PROG key E: the PROG LED
switches o .
If no action is performed, the procedure will end automatically after 30 minutes.
Programming call keys
Press the door release and AUX2 buttons C at the
same time.
On the entry panel, press the call key to be linked to the
receiver 4: a beep will confi rm that the setting has been
stored.
Going into Programming
Press the PROG key for at least 3 seconds 1 and then release it (within 6
seconds) as soon as the PROG LED fl ashes and the key back lighting lights up
as illustrated in fi gure 2.
Reprogramming
1
2
3
SW3
PROG RESET
PROG
SW3
PROG
PROG
>8’
>8’
<11’
<11’
GRESET
PROG
M2
ROG P
PROG
P
3 beep
3 beep
PROG RESET
PROG
SW3
PROG
PROG
<1’
<1’
4
4
SW3
P
R
SW3
PR
M2
1
1
2
2
Page 6 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 6 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Deactivating intercommunicating groups
To deactivate the intercom function, you simply have to disconnect the SW3
jumper 1; by doing this, programming of the intercom system is also inhibited.
To reactivate this function you must restore factory settings.
Once a receiver has been included in an intercommunicating group by
assigning the intercom call button, it cannot be excluded from this group.
If you want to change the intercom call button on a receiver which has
already been programmed as an intercommunicating receiver, or you want
to add new receivers to the group, repeat the operations detailed under
“Programming an intercommunicating group”.
Assigning intercommunicating groups
With the SW3 jumper inserted, press the PROG key for at least 8 seconds and
release it (within 11 seconds) 1 as soon as the PROG LED fl ashes and the key
back lighting comes on 2.
To enable the intercom function, go to the receiver that you want to programme,
and press the intercom call key you want to call from: a beep will sound to show
that programming has taken place 3. Repeat for all receivers to be included in
the intercommunicating group.
At the end, briefl y press the PROG key 4.
If no action is performed, the procedure will end automatically after 30
minutes.
Programming an intercommunicating group
Programming an intercommunicating group must be carried out AFTER assigning the call key to all of the receivers.
AUTOMATIC DOOR RELEASE function
For internal receivers that support the AUTOMATIC DOOR RELEASE function only.
This function is used to open the entrance automatically when there is a call from the entry panel. No communication is
activated and the call ends automatically.
Follow the instructions in the internal receiver manual.
M1
BOUT
PROG
M
PROGPROG
1
>3’
M1
BOUT
PROG
3
3
3
3A
3
3B
2
2
4
4
beep
beep
E
E
F
F
beep
beep
M
PROGPROG
G
<1’
Page 7 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 7 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Programming call keys
Press the door release and AUX2 buttons at the same time 5. On the entry
panel, press the call key to be linked to the receiver 6: a beep will confi rm that
the setting has been stored.
Continue, repeating the same operations for all the other receivers.
Exiting Programming
Briefl y press the PROG button on the power supply G. The PROG LED switches
o and the entry panel stops ringing.
If no action is performed, the procedure will end automatically after 30
minutes.
Going into Programming
Press the PROG button on the power supply 1 until the PROG LED lights
up. Failure of the PROG LED to light up, indicates a malfunction. Check the
connections and return to programming. The PROG LED and key back lighting
will fl ash 2.
Wait 5 seconds for the auto test to be completed and continue as shown below.
Programming Type of Keys
Press the fi rst key on the entry panel in the position shown 3/3A3B until the
back lighting LEDs stop fl ashing 4 and stay on. A beep sounds to signal that
you have entered "Programming call keys".
PROGRAMMING ENTRY PANELS WITH VA/01
First Programming with one entry panel
M
PROGPROG
A
A
>3’
1
1
1
1
2
2
E
E
3
3
4
4
1 P.E
1 P.E1 P.E 1 P.E
2 P.E
2 P.E2 P. E 2 P. E
beep
beep
6
6
G
beep
beep
M
PROGPROG
8
8
<1’
Page 8 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 8 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Exiting Programming
Briefl y press the PROG button. The PROG LED switches o .
If no action is performed, the procedure will end automatically after 30
minutes.
The operation may only be carried out from the entry panel
with the active beep signal (PE1 in fi g. E): to change the
entry panel from which the call programming is carried
out, press one of the call keys for at least 3 seconds.
Programming call keys
Press the door release and AUX2 buttons at the same time 6.
On the entry panel, press the call key to be linked to the receiver 7: a beep
will confi rm that the setting has been stored. Continue, repeating the same
operations for all the other receivers.
Going into Programming
Press the PROG button on the power supply 1 until the PROG LED lights up.
If the PROG LED immediately goes out, this indicates a malfunction in the
connections between the power supply and the entry panel. Check the
connections and return to programming.
The PROG LED and key back lighting will fl ash as shown in fi gure 2. Wait 5
seconds for the auto test to be completed and continue as shown below.
Programming Type of Keys
Press the fi rst key on the entry panel in the position shown 3 until the back
lighting LEDs stop fl ashing. Repeat this operation for all the entry panels to be
programmed 4: at the end the signals will have this confi guration E. A beep
sounds to signal that you have entered "Programming call keys".
First Programming with several entry panels
M
PROGPROG
1
1
>3’
1
2
2
1 P.E 2 P.E
beep
beep
beep
beep
4
beep
beep
M
PROGPROG
5
5
<1’
beep
beep
3
3
M
PROGPROG
6
6
>3’
1
G
G
1 P.E 2 P.E
Page 9 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 9 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Programming Type of Keys
In "Programming Call Keys" A press and hold down the PROG key on the power
supply 6 until you go into the "Programming Type of Keys" procedure G.
Exiting Programming
Briefl y press the PROG button. The PROG LED switches o .
If no action is performed, the procedure will end automatically after 30
minutes.
Continue, repeating the same operations for all the other
receivers. The operation may only be carried out from the
entry panel with the active beep signal (PE1 in fi g. 2): to
change the entry panel from which the call programming
is carried out, press one of the call keys for at least 3
seconds.
Programming call keys
Press the door release and AUX2 buttons at the same time 3. On the entry
panel, press the call key to be linked to the receiver 4: a beep will confi rm that
the setting has been stored.
Going into Programming
Press the PROG key on the power supply A until the PROG LED lights up. The
PROG LED and key back lighting will fl ash 2. Wait 5 seconds for the auto test
to be completed and continue as shown below.
Reprogramming
1
1
1
J
J
8
8
I
I
1 P.E
1 P.E
1 P.E
2 P.E
2 P.E
2 P.E
beep
beep
M
PROGPROG
K
K
<1’
Page 10 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 10 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Press one of the call keys on the entry panels to be reprogrammed, the LEDs
backlighting the call keys 8will stop fl ashing. Repeat this operation on all the
entry panels to be reprogrammed 8 and 9.
If all the entry panels are reprogrammed, the confi guration will be as shown
in fi gure J.
To exit reprogramming, briefl y press the PROG key on the power supply K: the
PROG LEDs and the LEDs backlighting the keys will go out.
If no action is performed, the procedure will end automatically after 30 minutes.
If an entry panel is added, replaced or removed, the modifi cations
are acquired by going into "Programming Type of Keys" (from fi gure
6 to K).
AUTOMATIC DOOR RELEASE function
For internal receivers that support the AUTOMATIC DOOR RELEASE function only.
This function is used to open the entrance automatically when there is a call from the entry panel. No communication is
activated and the call ends automatically.
Follow the instructions in the internal receiver manual.
2
2
2
1
1
VAS/101
2
2
1
LVC/01
2
VA/01
44
4
LVC/01 LC/01 LC/01
A
A
B
B
C
C
Page 11 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 11 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Connection examples
PEV 1
PEV 1
2
12
OUT
SW2
SW4
SW3
XDV/304
34
IN
SW0
M1
B
+
AL
AGATA V-VC
AGATA VC/B
AGATA V-VC
AGATA VC/B
M/S
CL.RES
M/S
CL.RES
M/S
CL.RES
2
B-C
M/S
SLAVE
MASTER
-
B
AL
-
+
M1
M1
B
+
AL
-
B
AL
-
+
M1
CL.RES
+
BOUT
-
M1
A
+
M2
-
-
M2
A
LVC/01
VAS/101
A
A
B
B
Page 12 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 12 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
VA/01
A
CN2
RS232 M1
12V
+
-
+12V
BIN1
BIN2
BIN3
BOUT
+
BOUT
-
M1
+
BOUT
-
M1
-
-
M2
+
BOUT
-
M1
-
-
-
-
A
LC/01
LVC/01
LC/01
12V
12V
M2 M2
C
C
Page 13 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 13 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
VA/01
VAS/101
XDV/304 XDV/304
La
Lb
Lc
Ld
L1 L2
Le
Le
Lf
L3
Page 14 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 14 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 15 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 15 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Distances
La+Le+L1(L2, L3) ≤150 m
Lb+Le+L1(L2, L3) ≤150 m
Lc+Le+ L1(L2, L3) ≤150 m
Ld+Le+ L1(L2, L3) ≤150 m
La+Lb+Lc+Ld+Le+L1+L2+L3 ≤600 m
Distances with VCM/2D
L1, L2, L3 ≤100 m
L1+L2+L3 ≤300 m
Distances with VCM/1D cable
La+Le ≤100 m *
Lb+Le ≤100 m *
Lc+Le ≤100 m
Ld+Le ≤100 m
Lf ≤25 m
2x2.5 mm2
Lf ≤60 m
* ≤ 80 m with YVL301+XDV/304
The product complies with the applicable reference directives.
Dismantling and disposal. Dispose of the packaging and the device properly at the end of its life cycle, according to the regulations in
force in the country where the product is used. The recyclable components bear the symbol and code for the material.
THE DATA AND INFORMATION PROVIDED IN THIS MANUAL ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT PRIOR NOTICE. MEASUREMENTS, UNLESS
OTHERWISE INDICATED, ARE IN MILLIMETRES.
Legislative references
This product complies with the applicable standards in force at the time of manufacturing.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
[email protected] - www.came.com
Page 16 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 16 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME LC01 - LVC01 Programming Manual

Type
Programming Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI