1
2
3
>8’’
<11’’
3 beep
PROG RESET
PROG
<1’’
4
SW3
P
SW3
PR
1
2
Page 6 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 6 - Manual FA01725-EN - 03/2022 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Deactivating intercommunicating groups
To deactivate the intercom function, you simply have to disconnect the SW3
jumper 1; by doing this, programming of the intercom system is also inhibited.
To reactivate this function you must restore factory settings.
Once a receiver has been included in an intercommunicating group by
assigning the intercom call button, it cannot be excluded from this group.
If you want to change the intercom call button on a receiver which has
already been programmed as an intercommunicating receiver, or you want
to add new receivers to the group, repeat the operations detailed under
“Programming an intercommunicating group”.
Assigning intercommunicating groups
With the SW3 jumper inserted, press the PROG key for at least 8 seconds and
release it (within 11 seconds) 1 as soon as the PROG LED fl ashes and the key
back lighting comes on 2.
To enable the intercom function, go to the receiver that you want to programme,
and press the intercom call key you want to call from: a beep will sound to show
that programming has taken place 3. Repeat for all receivers to be included in
the intercommunicating group.
At the end, briefl y press the PROG key 4.
If no action is performed, the procedure will end automatically after 30
minutes.
Programming an intercommunicating group
Programming an intercommunicating group must be carried out AFTER assigning the call key to all of the receivers.
AUTOMATIC DOOR RELEASE function
For internal receivers that support the AUTOMATIC DOOR RELEASE function only.
This function is used to open the entrance automatically when there is a call from the entry panel. No communication is
activated and the call ends automatically.
Follow the instructions in the internal receiver manual.