CAME KIT FREE DC-DVC Installation guide

  • Hello! I am an AI chatbot trained to assist you with the CAME KIT FREE DC-DVC Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
KIT FREE DC-DVC
KIT FREE DC
A/01
VA/01
DC/01 ME
DVC/01 ME
KIT FREE DVC
INSTALLATION INSTRUCTIONS
EN
E
n
g
l
i
sh
FB00967-EN
A
43,5
45
7,5 57
210
106
64,5
210
145
2
1
3
b
b
a
a
c
c
Page 2 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 2 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 2 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
General Notes
• Read the instructions carefully before beginning the installation and carry
out the actions as speci ed by the manufacturer.
The installation, programming, commissioning and maintenance of the
product must only be carried out by quali ed technicians, properly trained
in compliance with the regulations in force, including health and safety
measures and the disposal of packaging.
The installer must ensure that the information for the user, where there is
any, is provided and delivered.
• Before carrying out any cleaning or maintenance operation, disconnect the
devices from the power supply.
The equipment must only be used for the purpose for which it was
expressly designed.
The manufacturer declines all liability for any damage as a result of impro-
per, incorrect or unreasonable use.
eventuali danni derivanti da usi impropri, erronei ed irragionevoli.
The product complies with the applicable reference directives.
Dismantling and disposal. Dispose of the packaging and the device
properly at the end of its life cycle, according to the regulations in force in
the country where the product is used. The recyclable components bear the
symbol and code for the material.
The data and information provided in this manual are subject to change at
any time without prior notice. Measurements, unless otherwise indicated,
are in millimetres.
VA/01-A/01
Installation
The power supply unit must ALWAYS be installed horizontally. The device
can be installed on DIN rails (EN 50022) a, on a suitable switchboard, or
on the wall using the terminal board covers b. To dismantle it, proceed as
shown in  gure c.
NOTE. Ensure there is correct ventilation if the power supply
unit is installed in a metal case.
Technical data
Type VA/01-A/01
Power supply [VAC] 230
Max current demand [AAC] 0,35
Max energy dissipation [W] 25
Entry panels nominal power supply [VDC]18
Entry panels current demand [A] 0,6
Entry panels peak power supply [VDC]18
Entry panels peak current demand [A] 1,1 <15’
Rising cable power supply [VDC]20
Rising cable current demand [A] 0.8 for 1’
Rising cable current demand [A] 0.2 for 3’
Dimensions [DIN] 12
Storage temperature [°C] -25 ÷ + 70
Operating temperature [°C] 0 ÷ +35
Protection rating [IP] 30
0,1,
86%
56 352*
'/ '/
5),'
352*
²
+12V
BIN1 BIN2 BIN3 BOUT
0
$
a
a
b
b
c
e
e
f
f
g
g
h
h
d
d
B
C
130 mA 130 mA 35 mA
500 mA
320 mA
b
b
c
c
a
a
Page 3 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 3 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 3 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Functions
Terminal boards a
~Mains
~
b
Aux 1 output Open Collector max 100 mA
+12V Common
Aux 2 output Open Collector max 100 mA
+
Entry panel power supply 18 VDC (*)
BIN1 BUS line input from entry panel 1
BIN2 BUS line input from entry panel 2
BIN3 BUS line input from entry panel 3
BOUT Busbar output
(*) The appliance is electronically protected against overloads and short
circuits.
Connectors
c RS232: Reserved for future use
d MINI USB: Connector for programming from a PC
e PROG button
RFID PROG Jumper (**) f
5),'
352*
²
0
5),'
352*
²
5),'
352*
²
Default Code entry Code deletion
LEDs
Colour Meaning
e DL1 (**) Yellow Programming status
f DL2 Green USB connected
(**) Refer to the “Programming Manual for Entry Panels DC/01-DVC/01-
DC/01 ME-DVC/01 ME”.
Absorption
a With entry panel on standby’
b With solenoid lock on’
c With surveillance camera on
5),'
352*
²0
$
352*
>25’
>25’
5),'
352*
²0
352*
beep
beep
<1’
M1
PROGPROG
VA /01
5),'
352*
²0
352*
VA/01
VA/01
VA/01
E
5),'
352*
²0
$
352*
>25’
>25’
VA/01
5),'
352*
²0
352*
VA/01
5),'
352*
²0
352*
VA/01
F
Page 4 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 4 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 4 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Programming
Of an intercom group
Programming the intercom group must be done after
assigning the type of call key or call code to all the internal
receivers.
Press the power supply’s PROG key for at least 25 seconds, until the PROG
LED  ashes quickly a and then put the RFID jumper in position “+” b.
To enable the intercom function, swipe on the internal receiver that you want
to programme, and press the call button you want to call from: a beep will
sound to show that programming has taken place c.
Continue by repeating the same operations for all the other internal receivers
to be included in the intercom group.
To leave programming, brie y press the power supply’s PROG key d and put
the RFID PROG jumper in the default position e.
NOTE. If no action is performed, the procedure will automatically end after
30 minutes.
Once an internal receiver has been included in an intercom group by assigning
the call key, it can no longer be excluded from that group.
To change the call key of an internal receiver that has already been pro-
grammed to have the intercom facility, and therefore add new internal re-
ceivers to the group, just repeat the sequence of operations described above.
Deactivating the intercom facility
Press the power supply’s PROG key for at least 25 seconds, until the PROG
LED  ashes a and then put the RFID PROG jumper in position “+” b for
at least 20 seconds. At the end of that time, put the RFID PROG jumper in
the default position, to leave programming c.
Connection examples
One group of intercommunicating internal receivers can be programmed
with the VA/01 power supply, following the procedure just described. If you
need to con gure more than one intercom group VSE/301 devices must be
used. You cannot con gure one intercom group with VA/01 and others with
VSE/301 at the same time.
G
2
VA/01
4
2
4
VSE/301 VSE/301
VA/01
VA/01
2
2
4
VSE/301
AA B
AB
c
c
a
a
b
b
Page 5 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 5 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 5 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
A
BC
ED
a
500 mm
119 0 mm
100°
870 mm
500 mm
50 mm
180 mm
65 mm
82°
Page 6 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 6 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 6 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
DC/01 ME-DVC/01 ME
Wall mounting
With the wall plugs provided  x the entry panel at the desired height
respecting the positioning of the lens of the surveillance camera .
Push through pipe a, take o the terminal board cover and make the
connections .
WARNING. The wires must be uncovered until fl ush with
the wall and inserted as shown in (on the left the wires
coming from the power supply unit and on the right from
those relating to service functions).
Put back on the terminal board covers and assemble the front cover .
F
G
I
H
A
B
1
2
Page 7 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 7 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 7 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Recessed installation
Wall in the recessed box at the desired height, respecting the positioning of
the lens of the surveillance camera .
Push the pipe with the system conductors through one of the breaking
points ( point A).
When installing the recessed box any possible deformations can be avoided
by using the spacer provided ( point B).
Position the frame surround in the recessed box , push the connection
wires through hole a, hold the entry panel in place and attach it in a se-
mi-proud position ; take o the terminal covers and make the connections.
WARNING. The wires must be uncovered until fl ush with
the wall and inserted as shown in (on the left the wires
coming from the power supply unit and on the right from
those relating to service functions).
Once the connections have been made, push the entry panel up slightly to
meet the frame . Put back on the terminal board covers and assemble
the front cover .
Accessories
a Single height button DPS;
b Double height button DPH;
c Double DPD button;
d Single height plu DTS ME;
e Double height stopper DTH ME;
f Access control module with keyboard DNA ME;
g Access control module with RFID reader DRFID,
h Recessed boxDSI;
i Recessed frame DCI ME,
j Wall roof DTP
a
b
c
d
e
f
g
h
i
j
254
99 25
281
127
1,2
J
K
Page 8 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 8 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 8 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Technical data
Type DC/01ME-DVC/01ME
Power supply (VDC) 14-18
Absorption (mA) 320
Consumption in stand-by mode (mA) 130
Storage temperature (°C) -25 ÷ + 70
Operating temperature (°C) -15°C +50°C
IP Degree 54
Camera DVC/01ME
Standard video PAL/NTSC
Resolution (pixel) 680x512
Minimum lighting (LUX) 1
L
M1
CN4
M2
CN2
DATI
MINI USB
OUT
BOUT
PROG
f
f
e
e
b
b
g
g
c
c
d
d
a
a
Page 9 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 9 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 9 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Functions
Terminal boards a
+Power supply
14-18 VDC
BOUT Riser
b
Solenoid lock
12 V - 1 A max
Door lock release button (NA)
Door contact input (NC)
Ground
Entry panel enabling output (active towards earth)
Ground
Connectors
c CN2: Connector for the keyboard or RFID access control module.
d CN4: Additional push button panel connector.
e MINI USB: Programming connector.
Adjustments f
loudspeaker audio
microphone audio
solenoid lock 1-10 s. (default 1 s)
Signals g
Red - Call in progress
Green - Door open
Yellow - Conversation in progress
Blue - System busy
Programming
The entry panel is supplied already con gured through a call put through
to any receiver that has NEVER been programmed.
It is possible, however, to add buttons or receivers as explained in the entry
panel’s programming manual.
The VA/01 power supply unit automatically recognises the entry panel
connected the  rst time the ‘self-connection’ button is pressed. The power
supply unit is programmed after a couple of seconds.
b
b
c
c
a
a
2
4
4
VA/01
2
4
VA/01
VA/01
4
2
a
a
b
b
VA/01
A
CN2
RS232 M1
+
-
+12V
BIN1
BIN2
BIN3
BOUT
DVC/01-ME
+
BOUT
-
-
-
-
M2
M1
AGATA VC-V
CL.RESM/S
M1
B
+
DVC/01-ME
+
BOUT
-
M1
VA/01
A
CN2
RS232 M1
+
-
+12V
BIN1
BIN2
BIN3
BOUT
-
-
-
M2
AGATA VC-V
AGATA VC/B
CL.RESM/S
M1
AL
B
+
AGATA VC-V
AGATA VC/B
CL.RESM/S
M1
AL
B
+
AGATA VC-V
AGATA VC/B
CL.RESM/S
M1
AL
B
+
Page 10 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 10 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 10 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
Connection examples
c
c
VA/01
A
CN2
RS232
M1 DVC/01-ME
-
-
-
DVC/01-ME
-
-
-
12V
12V
M2
M2
+
BOUT
-
M1
+
-
+12V
BIN1
BIN2
BIN3
BOUT
+
BOUT
-
M1
4
1
2
3
12
OUT
SW2
SW4
SW3
XDV/304
34
IN
SW0
AGATA VC-V
AGATA VC/B
CL.RESM/S
M1
AL
B
+
AGATA VC-V
CL.RESM/S
AGATA VC-V
AGATA VC/B
CL.RESM/S
M1
AL
B
+
AGATA VC-V
CL.RESM/S
M1
B
+
M1
B
+
1
2
3
4
1
2
3
4
Page 11 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 11 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 11 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 12 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 12 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructionsPage 12 - Manual FB00967-EN - 11/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
/