CAME EVKIT, EV/KIT, PERLA, OPALE Installation guide

Category
Soundbar speakers
Type
Installation guide
VA/01
DVC/01
DVC/01 ME
PEV/01
OPALE
INSTALLATION MANUAL
EVKIT
EN
English
FB01044-EN
VIDEO ENTRY KIT
1
2
A
B
C
D
EF
Page 2 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
General Notes
• Read the instructions carefully before beginning the installation
and carry out the actions as specified by the manufacturer.
• The installation, programming, commissioning and mainte-
nance of the product must only be carried out by qualified tech-
nicians, properly trained in compliance with the regulations in
force, including health and safety measures and the disposal of
packaging.
• The installer must ensure that the information for the user,
where there is any, is provided and delivered.
• Before carrying out any cleaning or maintenance operation,
disconnect the devices from the power supply.
• The equipment must only be used for the purpose for which it
was expressly designed.
• The manufacturer declines all liability for any damage as a
result of improper, incorrect or unreasonable use.
The product complies with the applicable reference directives.
Dismantling and disposal. Dispose of the packaging and the
device properly at the end of its life cycle, according to the regu-
lations in force in the country where the product is used. The re-
cyclable components bear the symbol and code for the material.
The data and information provided in this manual are subject to
change at any time without prior notice. Measurements, unless
otherwise indicated, are in millimetres.
PEV/01
Installation
Remove the unit from the metallic support by sliding it after
pressing the plastic button A.
Fasten the metallic support to the round built-in box of Ø 60
mm B or to the rectangular box 503 C D using the provided
screws and observing the UP indication .
The recessed box must be fitted at a suitable height in relation
to the user.
Avoid excessive tightening of the screws.
Once the connections have been made, hook the video terminal
to the metal support E F.
1
2
Ð +
AL B
M/S
CL.RES
G
Page 3 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
To release the unit from the metal support, press the plastic hook
and lift the terminal G.
Technical data
Type PEV
Maximum current draw (mA) 200
Current draw in stand-by mode (mA) < 1
Single LED current draw (mA) 1
Storage temperature (°C) -25 to +70
Video standard PAL/NTSC
LCD TFT colour display (inches) 3.5
Function of terminals
M1
AL Alarm input
+
Doorbell
BBUS line input
CL. RES - Closing resistance
CL.RES CL.RES CL.RES
1 2 3
XDV/304
M/S - Master/Slave selector
MASTER SLAVE
M/S M/S
In case of simultaneous call, the audio/video communication
will be activated on the MASTER extension only.
D
G
H
X 5
beep
I
X 5
beep
C
F
B
A
E
Page 4 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
1- Going into Programming.
Press button 5 times in 5 secs A.
A short beep confirms that you have entered programming mode.
2- Programming the melody associated with a call from the entry panel.
To listen to the melodies in sequence, press key B.
To select the melody and exit programming, press key C.
To select the melody and continue with programming, press key D.
3- Programming the melody associated with a call from the front door.
To listen to the melodies in sequence, press key E.
To select the melody and exit programming, press key F.
To select the melody and continue with programming, press key G.
4- Programming the number of rings for the call.
Press key H as many times as you want it to ring (from 1 to 6 rings).
Three seconds after the last press of the key the call selected for the cho-
sen number of rings will be played back.
To exit programming, press key I.
See the entry panel documentation for call programming.
Setting melodies
All the programming stages described below must be carried out in sequence:
1
2
A
B
C
OPALEKP
1
B A
C B
D C
Page 5 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
OPALE
Wall-mounted installation
Separate the unit body from the frame A.
Fasten the OPALEKP wall-mounting support (optional) to the
recessed box using the screws provided; the support is com-
patible with the following recessed box models: round 60 mm
Ø, 503 rectangular, 506E rectangular, and OPALESI (optional).
To guarantee better stability, fasten the support with the screws
and plugs provided 1. Fasten the frame to the wall-mounting
support using the screws provided, avoiding tightening them too
much 2.Wire up the terminal board and put it back in its com-
partment C. Attach the device to the frame D.
Recessed installation C
Wall in the OPALESI recessed box (optional) flush with the wall,
following the instructions on the mortar guard provided.
Fasten the frame to the recessed box using the screws provided,
avoiding tightening them too much 1.
Wire up the terminal board and put it back in its compartment
B. Attach the device to the frame C.
10mm
Ø
10mm
Ø
D
OPALEKP
1
B
C
D
E F
158
138
28.5 30.9
OPALEKP
E
Page 6 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Recessed installation on plasterboard wall D
Hold the box up against the plasterboard wall and mark the 4
reference points for installation 1.
Make 4 holes, 10 mm in diameter, at the reference points. Cut
the plasterboard to make a compartment for the box in the wall
B.
Remove the 2 tabs on the box as shown in the figure C.
Slot the fixing terminals in the box as shown in the figure D.
Fit the recessed box in the hole made in the wall E.
Click the bottom of the terminals into place. If the wall is thick-
er than 2 cm, you need to cut the joints holding the two parts
of the terminal together; this will allow you to slide the bottom
part of the terminal into the desired position and then tighten
the screws F.
H
I
Fam. Rossi
A
2
16-18VDC
F
G
Page 7 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Terminal board F
+Local power supply
16-18 VDC
BBUS line input
+Doorbell
AL Alarm input
Closing resistance (CL.RES) G
The jumper should be inserted in the last device in the line only.
Master/Slave selector (SKM) H
If two or more receivers have been configured to answer the
same call, the preview image of the caller is shown only on the
master device(s).
Power supply source selector (BUS/LOCAL) I
A Position of the jumper with locally powered device
2 Position of the jumper with BUS-powered device
Technical data
Type OPALE
Power supply by BUS (VDC) 15-20
Separate X2 power supply (VDC) 16-18
Consumption (mA max) 250
Consumption in stand-by mode (mA)
<1
Single LED consumption (mA)
(call from porter, ringtone excluded) 1
Video standard PAL/NTSC
LCD TFT colour display (inches) 3.5
Protection rating (IP)
20
Storage temperature (°C) -25 to +70
Operating temperature (°C) 0 to +35
43,5
45
7,5 57
210
106
A
B
64,5
210
145
2
1
3
A
B
C
Page 8 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
VA/01
Installation
The power supplier must ALWAYS be installed horizontally.
The device can be installed on a DIN rail (EN 50022) in an appro-
priate electric panel or it may be wall-mounted using the protec-
tive terminal covers.
For disassembly, proceed as shown in figure B-C.
For the overall dimensions see figure A.
NOTE. Proper ventilation is required if the power supplier is
installed in a metal container.
Technical data
Type VA/01
Power supply [VAC] 230
Max current demand [AAC] 0,35
Max energy dissipation [W] 25
Entry panels nominal power supply [VDC] 18
Entry panels current demand [A] 0,6
Entry panels peak power supply [VDC] 18
Entry panels peak current demand [A] 1,1 <15’’ (*)
Rising cable power supply [VDC] 20
Rising cable current demand [A] 0.8 for 1’
Rising cable current demand [A] 0.2 for 3’
Dimensions [DIN] 12
Storage temperature [°C] -25 ÷ + 70
Operating temperature [°C] 0 ÷ +35
Protection rating [IP] 30
(*) 1.6 A <15’’ with rising cable not connected or connected
separately.
MINI
USB
RS232 PROG
DL2 DL1
RFID
PROG
+
Ð
+12V
BIN1 BIN2 BIN3 BOUT
M1
A
D
1BC
D
Page 9 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Functions D
Terminal boards A
~Mains
~
Morsettiera M1
Aux 1 output Open Collector max 100 mA
+12V Common
Aux 2 output Open Collector max 100 mA
+ Entry panel power supply 18 VDC (*)
BIN1 BUS line input from entry panel 1
BIN2 BUS line input from entry panel 2
BIN3 BUS line input from entry panel 3
BOUT Busbar output
(*) The appliance is electronically protected against overloads
and short circuits.
Connectors
A RS232: Reserved for future use
B MINI USB: Connector for programming from a PC
C PROG button (**)
RFID PROG Jumper (**)
RFID
PROG
+
Ð
M1
A
RFID
PROG
+
Ð
M1
A
RFID
PROG
+
Ð
M1
A
Default Code entry Code deletion
LED
Colour Meaning
DL1 (**) Yellow Programming status
DL2 Green USB connected
(**) Refer to the “Programming".
VA/01
VA/01 VA/01
VA/01
VA/01
VA/01 VA/01
VA/01
VA/01
VA/01 VA/01 VA/01
VA/01
130+320+500=950 mA <1100 mA 500+130+320+500=1450 mA >1100 mA
500 mA 500 mA 500 mA
320 mA 320 mA
130 mA 130 mA
35+35+35+130+130+35+130+35+35+35=635 mA >600 mA
130 mA 130 mA 130 mA35 mA 35 mA 35 mA 35 mA 35 mA 35 mA 35 mA
35+35+130+130+35+130+35+35=565 mA <600 mA
130 mA 130 mA 130 mA35 mA 35 mA 35 mA 35 mA 35 mA
Page 10 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Absorption
With entry panel ‘on standby’ With solenoid lock ‘on’ With surveillance camera on
130 mA 130 mA 35 mA 320 mA 500 mA
A
B
C
A
B
D
E
500 mm
1190 mm
100°
870 mm
500 mm
50 mm
180 mm
65 mm
82°
F
1
B
Page 11 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
DVC/01 ME
Wall mounting
fix the given plugs and screw the entry panel A at the desired
height considering the position of the lens of the camera B.
Run the hose with the system conductors as shown in figure A.
Extract the plastic terminal cover and wire the connections C.
WARNING. The connection cables must be unsheathed flush
with the wall and inserted as indicated in figure D (the
cables coming from the power supplier to the left and those
regarding service functions to the right).
Once all the connections have been made, re-insert the terminal
covers.
Perform the programming and adjustment operations of the entry
panel as described to the chapter “Programming”.
2
1
2
1
1
2
G
H
I
CN4
CN1
CN1
CN2
J K
Page 12 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Recessed installation
Install the recessed box at the desired height considering the
position of the lens of the camera B, but in advance, run the
hose with the system conductors through one of the breaking
points E1. During installation of the recessed box it is possible
to avoid any deformation by using the provided spacer E2.
To facilitate the connections, lay the frame on the built-in box F.
Introduce the cable connections in the special hole and lay the
entry panel on the frame as shown in figure F and fix it in a
semi-extract position G; extract the plastic terminal cover and
wire the connections.
WARNING. The connection cables must be inserted as in-
dicated in figure D (the cables coming from the power
supplier to the left and those regarding service functions
to the right).
Once the connections have been made bring into contact, by
gently pushing upwards, the entry panel and the frame H and
re-insert the terminal covers G.
Perform the programming and adjustment operations of the entry
panel as described to the chapter “Programming”.
Side-by-side wall installation
Entry panels can be placed side-by-side both horizontally and
vertically.
Using a cutter, remove the plastic details of the entry panel bases
I.
Run the connection wires between the entry panel bases J,
ensuring to follow the sequence indicated in figure K and L.
A
CN4
CN1
CN2
CN1
M
O
L
1
2
N
Page 13 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Side-by-side recessed installation
Entry panels can be placed side-by-side both horizontally and
vertically M locking the boxes with one another.
Before installing them, break the lower and side breaking points
as highlighted in figure M in order to run the connection ca-
ble from the push button entry panel to the main/previous entry
panel.
Using a cutter, remove the plastic details of the entry panel bas-
es N.
Run the connection wires between i the entry panel bases ensur-
ing to follow the sequence indicated in figure O.
P1
B
C
D
E
7
F
H
I
J
254
99 25
281
127
1,2
Q
Page 14 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Accessories P
1 Single height button DPS;
2 Double height button DPH;
3 Double DPD button;
4 Single height plu DTS ME;
E Double height stopper DTH ME;
F Access control module with keyboard DNA ME;
G Access control module with RFID reader DRFID,
8 Recessed box DSI;
9 Recessed frame DCI ME,
J Wall roof DTP
Technical data
Type DVC/01ME
Power supply (VDC) 14-18
Absorption (mA) 320
Consumption in stand-by mode (mA) 130
Storage temperature (°C) -25 ÷ + 70
Operating temperature (°C) -15°C +50°C
IP Degree 54
Standard video PAL/NTSC
Resolution (pixel) 680x512
Minimum lighting (LUX) 1
M1
CN4
M2
CN2
DATI
MINI USB
OUT
BOUT
PROG
65
2
G
3
4
1
R
Page 15 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Functions R
Terminal boards 1
+Power supply
14-18 VDC
BOUT Riser
Terminal boards 2
Solenoid lock
12 V - 1 A max
Door lock release button (NA)
Door contact input (NC)
Ground
Entry panel enabling output (active towards earth)
Ground
Connectors
3 CN2: Connector for the keyboard or RFID access control
module.
4 CN4: Additional push button panel connector.
5 MINI USB: Programming connector.
For the manual programming of the entry panels, the
self-connection order is BIN1-BIN2-BIN3.
Adjustments 6
loudspeaker audio
microphone audio
solenoid lock 1-10 s. (default 1 s)
Signals G
Red - Call in progress
Green - Door open
Yellow - Conversation in progress
Blue - System busy
M1
M2
M5
+12V
+12V
BIN1 BIN2 BIN3 BOUT
PROG
M1
CN4
M2
CN2
DATI
MINI USB
OUT
VLS/300
B
B
NO
C
+
BOUT
CN1
IN
M1
CN1
CN4
M2
CN2
PROG
DATI
MINI USB
1 2
ON
3
IN
OUT
VLS/101
M1
M2
M5
+12V
+18V
BIN1 BIN2 BIN3 BOUT
1
2
1
2
BOUT
Page 16 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
111
12
13
14
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
1
10
9
8
7
6
5
2
3
4
111
12
13
14
10
9
8
7
6
5
2
3
4
1
7
8
6
5
2
3
4
7
8
9
10
11
12
13
14
111
12
13
14
10
9
8
7
6
5
2
3
4
1
1
27
5
4
3
1
6
2
3
4
3
5
7 8
6
4
2
1
3
5
7 8
6
4
2
Page 17 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Manual programming of entry panels
It is possible to programme only one or several audio/video entry
panels that have the same calls (unless "blind units" are used
that disable one or more of them).
It is possible to programme entry panels (connected to the same
power supply) with dierent types of keys, still respecting the
sequence shown on the left.
It is not possible to pro-
gramme entry panels with
dierent types of keys.
Programming with PC soft-
ware removes all of the re-
strictions just outlined.
M1
A
PROGPROG
>3’
1
33 A
D
3 B
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
3 C
y
E
Fbeep
M1
A
PROGPROG
78
<1’
2
Page 18 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
PROGRAMMING ENTRY PANELS
First Programming with ONE entry panel
Entering Programming Mode. Press the PROG key on the power supply 1 until the
PROG LED lights up. If the PROG LED immediately goes out, this indicates a malfunction
in the connections between the power supply and the entry panel. Check the connec-
tions and return to programming. The LEDS on the entry panels light up as shown in fig-
ure 2. Wait 5 seconds for the auto test to be completed and continue as shown below.
Programming Type of Keys. Press the first key on the entry panel 3/3A/3B until
the LED stops flashing along with the backlighting LEDs 4.
Programming the call keys. Lift the receiver (if present) of the extension that you want
to programme then press the door lock release and AUX2 5 buttons. On the
entry panel, press the call key to associate with the internal extension 6: an acoustic
signal will confirm that the setting was stored. Hang up the receiver again, if necessary
h and continue, repeating the same operations for the other extensions.
Exiting Programming. Briefly press the PROG key on the power supply 7: the PROG
LED and the LEDs on the entry panels will go out. NOTE. If no action is performed, the
procedure will end automatically after 30 minutes.
Programming entry panel video cameras. While programming the call keys the
"visual range" of the video camera can be adjusted from any receiver (with handset
raised, it there is one), by pressing on the "Self-connection" key 8.
Should call keys be present ONLY ON ADDITIONAL BUTTON PANELS, the opera-
tion shown in figure 3 is carried out on these as shown in figure 3C.
3
8
4
6
9
7
5
2
1
100 °
82 °
54 °
72 °
1÷9
0
9
J
M1
A
PROGPROG
>3’
1
2
3
4
56
Entry panel 1
Entry panel 1
Entry panel 1
Entry panel 1 Entry panel 1
Entry panel 2
Entry panel 2
Entry panel 2
Entry panel 2 Entry panel 2
Entry panel 3
Entry panel 3
Entry panel 3
Entry panel 3 Entry panel 3
Page 19 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
From the default settings it is possible to scroll through the following ones I by press-
ing the AUX1 key or to go back to the previous ones with the AUX2 key J: the
setting is saved automatically.
Entry panel brightness level adjustment. While programming the call keys the entry
panel brightness level can be adjusted from any receiver. Pressing the "Self-connec-
tion" key on the receiver causes the video camera of the entry panel for which the
brightness level is to be adjusted to be activated. The brightness level can be increased/
decreased by using a previously assigned call key, or by simulating a call from DNA.
First Programming with SEVERAL entry panels
Entering Programming Mode. Press the PROG key on the power supply 1 until the
PROG LED lights up. If the PROG LED immediately goes out, this indicates a malfunction
in the connections between the power supply and the entry panel. Check the connec-
tions and return to programming. The LEDS on the entry panels light up as shown in fig-
ure 2. Wait 5 seconds for the auto test to be completed and continue as shown below.
Programming Type of Keys. Press the first key on the entry
panel 3 until the LED stops flashing along with the back-
lighting LEDs 4. Repeat this operation for all the entry panels
to be programmed 4 5: at the end the signals will have this
configuration 6.
- Should call keys be present ONLY ON ADDITIONAL BUTTON
PANELS, proceed as shown in the NOTE on page 14.
beep
beep
7
3
8
4
2
M1
A
PROGPROG
>3’
1
Entry panel 1 Entry panel 2 Entry panel 3
Page 20 - Manual FB01044-EN - vers. 1 - 01/2018- © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice.
Programming the call keys. Lift the receiver (if present) of the extension that you
want to programme then press the door lock release and AUX2 7 buttons.
On the entry panel, press the call key to associate with the internal extension 8: an
acoustic signal will confirm that the setting was stored. Hang up the receiver again, if
necessary and continue, repeating the same operations for the other extensions. The
operation may only be performed from the entry panel with the LED o (PE1 in fig.
6): to change the entry panel from which the call programming is performed, press
one of the first 4 call key positions for at least 3s (or press key 1 followed by key for
entry. panels with DNA).
Exiting Programming. Briefly press the PROG key on the power supply: the PROG LEDs and the LEDs on the entry panels will go out.
NOTE. If no action is performed, the procedure will end automatically after 30 minutes.
Programming entry panel video cameras. While programming the call keys the "visual range" of the video camera can be adjusted
in the way already described.
Entry panel brightness level adjustment. While programming the call keys the entry panel brightness level can be adjusted in the
way already described.
Reprogramming Procedure
Entering Programming Mode. Press the PROG key on the power supply 1 until the
PROG LED lights up. The LEDS on the entry panels light up as shown in figure 2. Wait
5 seconds for the auto test to be completed and continue as shown below.
Programming the call keys. Lift the receiver (if present) of the
extension that you want to programme then press the door lock
release and AUX2 3 buttons. On the entry panel, press
the call key to be associated with the internal extension 4: an
acoustic signal will confirm that the setting was stored. Hang
up the receiver again, if necessary and continue, repeating the
same operations for the other extensions.
The operation may only be performed from the entry panel with
the LED o (PE1 in 2): to change the entry panel from which
call programming is performed, press one of the first 4 call key
positions for at least 3s (or press key 1 followed by key for
entry. panels with DNA).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

CAME EVKIT, EV/KIT, PERLA, OPALE Installation guide

Category
Soundbar speakers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI