  • Hello! I am an AI chatbot trained to assist you with the Jackson RackStar 66S Installation, Operation & Service Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
RACKSTAR
RackStar
Manual • 07610-004-33-05-E
INSTALLATION, OPERATION,
AND SERVICE MANUAL
RACKSTAR
SERIES CONVEYOR DISHMACHINES
®
®
MANUFACTURER'S LIMITED WARRANTY
(APPLICABLE ONLY IN THE UNITED STATES AND CANADA)
WARRANTY REGISTRATION:
To register your Jackson Dishmachine’s warranty go to www.jacksonwws-warranty.com or call 1-888-800-5672. Failure to
register the Dishmachine will void the warranty.
ONE YEAR LIMITED PARTS AND LABOR WARRANTY
For a period of one (1) year from date of original installation of a new Jackson Dishmachine (but in no event to exceed
eighteen (18) months from date of shipment from Jackson’s factory), Jackson WWS, Inc. (Jackson) will repair or replace,
at its discretion, any original part that proves defective in materials or workmanship at the time the Dishmachine was
purchased; provided that (i) the Dishmachine has not been altered, (ii) the Dishmachine has been properly installed,
maintained, and operated under normal use conditions and in accordance with the applicable installation, operation and
service manual available on the Jackson website, and (iii) a warranty claim is reported to a Jackson Authorized Service
Agency within the warranty period. This warranty includes replacement with Jackson specied genuine replacement
parts, purchased directly from a Jackson Authorized Parts Distributor or Service Agency. Use of generic replacement
parts may create a hazard and shall void this warranty.
THIS WARRANTY DOES NOT APPLY OUTSIDE THE UNITED STATES AND CANADA.
Jackson will pay the labor to repair or replace a defective original part as a part of the warranty, provided that a Jackson
Authorized Service Agency performs the labor. Any repair or replacement work by anyone other than a Jackson
Authorized Service Agency is the sole responsibility of the purchaser. Labor coverage is limited to regular hourly rates;
Jackson will not pay overtime premiums or emergency service charges.
Accessory components (such as table limit switches, pressure regulators, and drain water tempering kits) that are not
installed by Jackson at the factory and are shipped with the Dishmachine carry only a (1) one-year parts warranty. Labor
to repair or replace these components is not included in the warranty or covered by Jackson. Booster heaters not
manufactured by Jackson are not covered by this warranty but are warranted by their respective manufacturers.
This warranty is void if any defect or failure is a direct result from shipping, handling, re, water, accident, alteration,
modication, misuse, abuse, ood, acts of God, burglary, casualty, attempted repair by unauthorized persons, use of
replacement parts not authorized by Jackson, improper installation, installation not in accordance with local electrical and
plumbing codes, if the serial number has been removed or altered, if the Dishmachine is used for any purpose other than
originally intended, or if the equipment is installed for residential use.
Jackson does not authorize any other entity or person, including, without limitation, any entity or person who deals in
Jackson Dishmachines, to change this warranty or create any other obligation in connection with Jackson Dishmachines.
TRAVEL LIMITATIONS:
Jackson limits warranty travel time to the customer site within 50 miles of the Jackson authorized service agent’s ofce
and during regular business hours. Jackson will not pay for travel time and mileage that exceeds these limits, or any fees
such as those for air or boat travel without prior authorization.
REPLACEMENT PARTS WARRANTY:
For a period of (90) ninety days from the date of installation by a Jackson Authorized Service Agency (but in no event to
exceed (180) one-hundred-eighty days from the date of purchase from a Jackson Authorized Parts Distributor or Service
Agency), Jackson will repair or replace, at its discretion, any Jackson genuine replacement parts that prove defective
in materials or workmanship at the time the replacement parts were installed. This warranty does not include paying
the labor to repair or replace the replacement part. This warranty is subject to all conditions, exclusions and limitations
applicable to the Dishmachine.
07610-004-33-05-E
ii
MANUFACTURER'S LIMITED WARRANTY (CONT.)
(APPLICABLE ONLY IN THE UNITED STATES AND CANADA)
PRODUCT CHANGES:
Jackson reserves the right to make changes in design and specication of any component of the Dishmachine as
engineering or necessity requires.
DISCLAIMER OF WARRANTIES:
THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, THAT ARE NOT SET FORTH
HEREIN, OR THAT EXTEND BEYOND THE DURATION HEREOF.
LIMITATION OF REMEDIES AND LIABILITIES:
YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR
REPLACEMENT AS PROVIDED HEREIN.
UNDER NO CIRCUMSTANCES WILL JACKSON BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES, OR FOR DAMAGES IN THE NATURE OF PENALTIES. JACKSON’S LIABILITY ON ANY CLAIM OF ANY
KIND WITH RESPECT TO THE GOODS OR SERVICES COVERED HEREUNDER SHALL IN NO CASE EXCEED THE
PRICE OF THE GOODS OR SERVICES OR PART THEREOF WHICH GIVES RISE TO THE CLAIM.
ITEMS NOT COVERED:
THIS WARRANTY DOES NOT COVER (1) ADJUSTMENTS INCLUDING, BUT NOT LIMITED TO, TIMER CAMS,
THERMOSTATS, DOORS, TANK HEATER ADJUSTMENTS OR CLUTCHES; (2) AIR FREIGHT OR OVERNIGHT
FREIGHT; (3) ANY AMOUNT EXCEEDING ORIGINAL PURCHASE PRICE; (4) CLEANING OF DRAIN VALVES,
GAS LINES, RINSE/WASH NOZZLES, STRAINERS, SCREENS, OR SPRAY PIPES; (5) CLEANING OR DELIMING
OF THE DISHMACHINE OR ANY COMPONENT INCLUDING, BUT NOT LIMITED TO, WASH ARMS, RINSE
ARMS AND STRAINERS; (6) CONDITIONS CAUSED BY THE USE OF INCORRECT (NON-COMMERCIAL)
GRADE DETERGENTS; (7) CORROSION FROM CHEMICALS DISPENSED IN EXCESS OF RECOMMENDED
CONCENTRATIONS; (8) COSMETIC DAMAGE, INCLUDING BUT NOT LIMITED TO, SCRATCHES, DENTS, CHIPS,
AND OTHER DAMAGE TO THE DISHMACHINE FINISHES, UNLESS SUCH DAMAGE RESULTS FROM DEFECTS IN
MATERIALS AND WORKMANSHIP AND IS REPORTED TO JACKSON WITHIN (30) THIRTY DAYS FROM THE DATE
OF INSTALLATION; (9) DAMAGE CAUSED BY LABOR DISPUTE; (10) DAMAGES RESULTING FROM IMPROPER
CONNECTION TO UTILITY SERVICE; (11) DAMAGES RESULTING FROM WATER CONDITIONS, INADEQUATE OR
EXCESSIVE WATER PRESSURE, ACCIDENTS, ALTERATIONS, IMPROPER USE, ABUSE, HANDLING, OVERLOADS,
TAMPERING, IMPROPER INSTALLATION OR FAILURE TO FOLLOW MAINTENANCE AND OPERATING
PROCEDURES; (12) DISCOLORATION, RUST OR OXIDATION OF SURFACES RESULTING FROM CAUSTIC
OR CORROSIVE ENVIRONMENTS, INCLUDING, BUT NOT LIMITED TO, HIGH SALT CONCENTRATIONS, HIGH
MOISTURE OR HUMIDITY, OR EXPOSURE TO CHEMICALS; (13) ELECTRIC BOOSTERS, FEED LINES, FLEX HOSE,
FUSES, GARBAGE DISPOSALS, OR GAS PILOTS; (14) EXCESSIVE LIME, MINERAL, OR ALKALINE BUILDUP; (15)
EXPENSES DUE TO DISCONNECTION, DELIVERY, RETURN AND REINSTALLATION; (16) FAILURE OF ELECTRICAL
COMPONENTS DUE TO CONNECTION OF CHEMICAL DISPENSING EQUIPMENT INSTALLED BY OTHERS; (17)
FAILURE OF FACILITY WATER HEATER TO MAKE TEMPERATURE; (18) FAILURE TO MAINTAIN WATER HARDNESS
LOWER THAN 3.0 GRAINS, PH BETWEEN 7.0 AND 8.5 AND TOTAL DISSOLVED SOLIDS BELOW 250 PPM; (19)
FAILURE TO COMPLY WITH LOCAL ELECTRICAL BUILDING CODES; (20) LEAKS OR DAMAGE RESULTING FROM
SUCH LEAKS CAUSED BY THE INSTALLER, INCLUDING THOSE AT MACHINE TABLE CONNECTIONS, OR BY
CONNECTION OF CHEMICAL DISPENSING EQUIPMENT INSTALLED BY OTHERS; (21) OPENING OR CLOSING OF
UTILITY SUPPLY VALVES OR SWITCHING OF ELECTRICAL SUPPLY CURRENT; (22) PERFORMANCE OF REGULAR
MAINTENANCE AND CLEANING AS OUTLINED IN THE OPERATOR’S GUIDE; (23) REMOVAL OR REINSTALLATION
OF INACCESSIBLE DISHMACHINES OR BUILT-IN FIXTURES THAT INTERFERE WITH SERVICING, REMOVAL OR
REPLACEMENT OF THE DISHMACHINE; (24) REPLACEMENT WEAR ITEMS INCLUDING, BUT NOT LIMITED TO,
CURTAINS, DRAIN BALLS, DOOR GUIDES, GASKETS, O-RINGS, SEALS, SQUEEZE TUBES, AND BEARINGS; (25)
RESIDENTIAL USE; (26) USE WITH UTILITY SERVICE OTHER THAN THAT DESIGNATED ON THE RATING PLATE.
iii
07610-004-33-05-E
Revision
Letter
Revision
Date
Made
by
Applicable
ECNs
Details
A 9-21-16 JH N/A Initial release of manual.
B 10-25-16 JH N/A
Corrected delime instructions.
Corrected P/Ns for item #6 on pg. 42.
Updated pg. 13 to change the pressure regulator from standard to optional.
Updated Miscellaneous Electrical Components page.
Added a Door Assemblies page.
Added a Frame Assembly page.
Added Display Fault Codes.
C 1-19-18 JH
8438
8504
8524
8526
8546
8547
8569
8570
8578
8579
Added the Energy Recovery unit to the manual.
Changed maximum water hardness to 3 GPG.
Added a Connection Points section to pg. 24.
Changed detergent connection point location on pg. 24.
Added links to external device and exhaust fan timer instructions to pg. 25.
Added Steam unit dimensional drawings.
Changed inlet steam ow pressure to 10-30 PSI.
Changed plumbing throughout to single-point connection.
Added dispenser connection fuses and P/Ns to pg. 41.
Updated Pawl Bar Assembly, pg. 57.
Corrected Rack Paddle Assembly, pg. 58.
Replaced item #12 on pgs. 59 and 60 with new part.
Added Drive Plate components to pg. 60.
Added communication cable to Display Assembly page.
Added a Frame Assembly page.
Replaced item #7 on pg. 66 with new part.
Changed P/N of Drive Link on pg. 67.
Added Booster Heater Add-on Kit to pg. 70.
Updated schematics.
D 3-13-18 JH N/A
Updated dimensional drawings with depiction of drain air-gap and associated
specications.
Updated Drain Line Connection section to be more descriptive and added
depiction of drain air-gap and associated specications.
E 9-10-20 JH
8553
8586
8609
8615
8623
8626
8627
8629
8654
8735
8736
Added 600 V unit to the manual.
Added HH unit to the manual.
Updated Electrical Requirements pgs.
Added instructions hyperlink icon and linked to applicable documents
throughout.
Added section on adjusting doors.
Added section on motor rotation.
Added section on table limit switch option.
Revised connection points section.
Updated curtain sizes.
Corrected delime instructions.
Added high-limit thermostat.
Updated inlet plumbing assemblies.
Updated Wash and Pre-wash Arm sections.
Updated pre-wash plumbing assembly.
Created Rack Rails section and added all rails and components.
Updated schematics.
REVISION HISTORY
iv
iv
The manufacturer provides
technical support for all of
the dishmachines detailed
in this manual. We strongly
recommend that you refer to
this manual before making a call
to our technical support staff.
Please have this manual open
when you call so that our staff
can refer you, if necessary, to
the proper page.
Technical support is not
available
on holidays.
Contact technical support toll
free at 1-888-800-5672.
Technical support is available
for service personnel only.
RackStar
®
44
RackStar
®
66
Electrically-heated rack conveyor machine,
available in chemical-sanitizing and
hot-water-sanitizing models.
RackStar
®
44ER
RackStar
®
66ER
Electrically-heated, hot-water-sanitizing
rack conveyor machine
with Energy Recovery System.
RackStar
®
44S
RackStar
®
66S
Steam-heated, hot-water-sanitizing
rack conveyor machine.
Models also available with Higher Hood
(25-inch Dish Clearance)
NOMENCLATURE
TABLE OF CONTENTS
GUIDES
Symbols ......................................................................................................................................1
Abbreviations & Acronyms ..........................................................................................................1
SPECIFICATIONS
Electric/Steam Dimensions .........................................................................................................2
Energy Recovery Dimensions ....................................................................................................6
Side-loader Dimensions............................................................................................................10
Steam Booster Dimensions ......................................................................................................11
Operating Parameters ..............................................................................................................12
Electrical Requirements ............................................................................................................14
INSTALLATION
Installation Instructions ............................................................................................................. 19
Inspection....................................................................................................................... 19
Unpacking ...................................................................................................................... 19
Leveling.......................................................................................................................... 19
Adjusting Doors.............................................................................................................. 19
Plumbing ........................................................................................................................ 19
Drain Line Connection ................................................................................................... 20
Steam Line Connection.................................................................................................. 21
Electrical Power Connections ........................................................................................ 21
Motor Rotation ............................................................................................................... 22
Ventilation ...................................................................................................................... 22
Thermostats ................................................................................................................... 22
Table Limit Switch Option .............................................................................................. 22
Chemical Feeder Equipment ......................................................................................... 23
Connection Points .......................................................................................................... 23
External Device Wiring ................................................................................................... 24
Exhaust Fan Timer ......................................................................................................... 24
Curtain Installation ......................................................................................................... 25
OPERATION
Operating Instructions............................................................................................................... 26
Preparation .................................................................................................................... 26
Power Up ....................................................................................................................... 26
First Rack ....................................................................................................................... 27
vi
TABLE OF CONTENTS
OPERATION
Ware Preparation ........................................................................................................... 27
Washing a Rack of Ware ............................................................................................... 27
Operational Inspection ................................................................................................... 27
Shutdown & Cleaning .................................................................................................... 28
Display Instructions ........................................................................................................ 29
Delime Instructions ........................................................................................................ 30
MAINTENANCE
Preventative Maintenance ........................................................................................................ 31
TROUBLESHOOTING
Troubleshooting ........................................................................................................................ 32
Programming ............................................................................................................................ 34
Fault Codes .............................................................................................................................. 36
PARTS
Control Box ............................................................................................................................... 38
Display ...................................................................................................................................... 39
Miscellaneous Electrical Components ...................................................................................... 40
Wash Heater & Shroud ............................................................................................................. 41
Wash Heaters ........................................................................................................................... 42
Pump Suction ........................................................................................................................... 43
Plumbing ................................................................................................................................... 44
Pre-wash Fill Plumbing ............................................................................................................. 46
Energy Recovery Plumbing ...................................................................................................... 47
Wash System ............................................................................................................................ 50
Pre-wash System...................................................................................................................... 52
Rinse System............................................................................................................................ 54
Plumbing Options ..................................................................................................................... 56
Pawl Bar ................................................................................................................................... 57
Rack Rails ................................................................................................................................. 58
Drive Assembly ......................................................................................................................... 60
Ventilation Cowl ........................................................................................................................ 62
Ventilation Cowl for Unhooded Side-loader .............................................................................. 63
Motor Overloads ....................................................................................................................... 64
vii
TABLE OF CONTENTS
PARTS
Side-loaders.............................................................................................................................. 65
Side-loader Drive Linkage ........................................................................................................ 68
Steam Coil ........................................................................................................................69
Booster Heater (Electric) .......................................................................................................... 70
Booster Heater Add-on Kit (Electric) ......................................................................................... 71
Frame ....................................................................................................................................... 72
Doors ........................................................................................................................................ 73
Energy Recovery System ......................................................................................................... 74
Miscellaneous/Options .........................................................................................................76
SCHEMATICS
208/230 V, 50/60 Hz, 3-Phase .................................................................................................. 77
460 V, 50/60 Hz, 3-Phase ......................................................................................................... 78
600 V, 50/60 Hz, 3-Phase ......................................................................................................... 79
Steam ....................................................................................................................................... 80
Side-loader ............................................................................................................................... 81
ADDENDUM
Display Template ...................................................................................................................... 82
07610-004-33-05-E
1
GUIDES
GUIDES
SYMBOLS
ABBREVIATIONS & ACRONYMS
ANSI - American National Standards Institute
CFM - Cubic Feet per Minute
ER - Energy Recovery
GHT - Garden Hose Thread
GPM - Gallons per Minute
GPG - Grains per Gallon
HP - Horse Power
Hz - Hertz
ID - Inside Diameter
kW - Kilowatts
MIN - Minimum
NFPA - National Fire Protection Association
NPT - National Pipe Thread
ppm - Parts per Million
PSI - Pounds per Square Inch
V - Volts
40º - 40-degree Rise
70º - 70-degree Rise
5
5
!
CAUTION
!
WARNING
NOTICE
- Risk of Injury to Personnel
- Risk of Damage to Equipment
- Risk of Electrical Shock
- Lockout Electrical Power
- Reference Data Plate
- Important Note
i
- Caustic Chemicals
- Instructions Hyperlink
2
07610-004-33-05-E
4 MIN
[102 mm]
12
[305 mm]
22 1/2
[572 mm]
16
[406 mm]
20
[508 mm]
15
[381 mm]
30
[762 mm]
44
[1118 mm]
64
[1626 mm]
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4
[6 mm] per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
4
[102 mm]
5
[127 mm]
15 1/8
[384 mm]
8
[202 mm]
6 7/8
[210 mm]
21
[533 mm]
ADJUSTABLE FROM 51 1/2 TO 54
[1308 mm TO 1372 mm]
Primary Electrical Opening
(Provided on both ends of machine.)
Secondary Electrical Opening
(Provided on both ends of machine.)
Single-point (Option): uses only
primary opening to power the
entire machine.
Dual-point (Standard): also uses
secondary opening for a
separate connection to
only the booster.
LEGEND
A - Electrical Connection
B - Main Water Inlet
(1/2" NPT, 110 °F MIN (18 kW Booster),
140 °F MIN (12 kW Booster), or 180 °F MIN
(No Booster or Supplied from Steam Booster))
C - Drain Connection
(1 1/2" NPT)
D - Vent Connections
(Including Dampers)
E - Steam Connection
(3/4" NPT)
- Open Door
- High Hood Option
All dimensions from the floor can be increased
1 3/4” using the machine’s adjustable feet.
Items in red are not supplied with the machine.
Items in blue are for the Steam option.
A
25 1/4
[642 mm]
25
[635 mm]
CLEARANCE
(HIGH HOOD)
34 1/4
[870 mm]
TABLE HEIGHT
8
[202 mm]
73 3/4
[1873 mm]
11 3/4
[297 mm]
4 MIN
[102 mm]
19 3/4
[502 mm]
CLEARANCE
(STANDARD)
62 1/4
[1581 mm]
68 1/2
[1740 mm]
68 1/8
[1730 mm]
A
B
44" LEFT-TO-RIGHT
SPECIFICATIONS
44" ELECTRIC/STEAM DIMENSIONS
07610-004-33-05-E
3
4 MIN
[102 mm]
12
[305 mm]
22 1/2
[572 mm]
16
[406 mm]
20
[508 mm]
15
[381 mm]
30
[762 mm]
44
[1118 mm]
64
[1626 mm]
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4
[6 mm] per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
4
[102 mm]
5
[127 mm]
15 1/8
[384 mm]
8
[202 mm]
6 7/8
[210 mm]
21
[533 mm]
ADJUSTABLE FROM 51 1/2 TO 54
[1308 mm TO 1372 mm]
Primary Electrical Opening
(Provided on both ends of machine.)
Secondary Electrical Opening
(Provided on both ends of machine.)
Single-point (Option): uses only
primary opening to power the
entire machine.
Dual-point (Standard): also uses
secondary opening for a
separate connection to
only the booster.
LEGEND
A - Electrical Connection
B - Main Water Inlet
(1/2" NPT, 110 °F MIN (18 kW Booster),
140 °F MIN (12 kW Booster), or 180 °F MIN
(No Booster or Supplied from Steam Booster))
C - Drain Connection
(1 1/2" NPT)
D - Vent Connections
(Including Dampers)
E - Steam Connection
(3/4" NPT)
- Open Door
- High Hood Option
All dimensions from the floor can be increased
1 3/4” using the machine’s adjustable feet.
Items in red are not supplied with the machine.
Items in blue are for the Steam option.
A
25 1/4
[642 mm]
25
[635 mm]
CLEARANCE
(HIGH HOOD)
34 1/4
[870 mm]
TABLE HEIGHT
8
[202 mm]
73 3/4
[1873 mm]
11 3/4
[297 mm]
4 MIN
[102 mm]
19 3/4
[502 mm]
CLEARANCE
(STANDARD)
62 1/4
[1581 mm]
68 1/2
[1740 mm]
68 1/8
[1730 mm]
A
B
SPECIFICATIONS
44" ELECTRIC/STEAM DIMENSIONS
44" RIGHT-TO-LEFT
4
07610-004-33-05-E
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4 [6 mm]
per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
4 MIN
[102 mm]
12
[305 mm]
39 3/4
[1009 mm]
16
[406 mm]
20
[508 mm]
15
[381 mm]
30
[762 mm]
66
[1676 mm]
86
[2184 mm]
[102 mm]
4
[102 mm]
5
[127 mm]
15 1/8
[384 mm]
8
[202 mm]
6 7/8
[210 mm]
43 3/8
[1101 mm]
ADJUSTABLE FROM 73 1/2 TO 76
[1867 mm TO 1930 mm]
25 1/4
[642 mm]
25
[635 mm]
CLEARANCE
(HIGH HOOD)
34 1/4
[870 mm]
TABLE HEIGHT
8
[202 mm]
73 3/4
[1873 mm]
11 3/4
[297 mm]
4 MIN
[102 mm]
19 3/4
[502 mm]
CLEARANCE
(STANDARD)
62 1/4
[1581 mm]
68 1/2
[1740 mm]
68 1/8
[1730 mm]
Primary Electrical Opening
(Provided on both ends of machine.)
Secondary Electrical Opening
(Provided on both ends of machine.)
Single-point (Option): uses only
primary opening to power the
entire machine.
Dual-point (Standard): also uses
secondary opening for a
separate connection to
only the booster.
LEGEND
A - Electrical Connection
B - Main Water Inlet
(1/2" NPT, 110 °F MIN (18 kW Booster),
140 °F MIN (12 kW Booster), or 180 °F MIN
(No Booster or Supplied from Steam Booster))
C - Drain Connection
(1 1/2" NPT)
D - Vent Connections
(Including Dampers)
E - Steam Connection
(3/4" NPT)
- Open Door
- High Hood Option
All dimensions from the floor can be increased
1 3/4” using the machine’s adjustable feet.
Items in red are not supplied with the machine.
Items in blue are for the Steam option.
A
A
B
66" LEFT-TO-RIGHT
SPECIFICATIONS
66" ELECTRIC/STEAM DIMENSIONS
07610-004-33-05-E
5
SPECIFICATIONS
66" ELECTRIC/STEAM DIMENSIONS
66" RIGHT-TO-LEFT
Primary Electrical Opening
(Provided on both ends of machine.)
Secondary Electrical Opening
(Provided on both ends of machine.)
Single-point (Option): uses only
primary opening to power the
entire machine.
Dual-point (Standard): also uses
secondary opening for a
separate connection to
only the booster.
LEGEND
A - Electrical Connection
B - Main Water Inlet
(1/2" NPT, 110 °F MIN (18 kW Booster),
140 °F MIN (12 kW Booster), or 180 °F MIN
(No Booster or Supplied from Steam Booster))
C - Drain Connection
(1 1/2" NPT)
D - Vent Connections
(Including Dampers)
E - Steam Connection
(3/4" NPT)
- Open Door
- High Hood Option
All dimensions from the floor can be increased
1 3/4” using the machine’s adjustable feet.
Items in red are not supplied with the machine.
Items in blue are for the Steam option.
4 MIN
[102 mm]
12
[305 mm]
39 3/4
[1009 mm]
16
[406 mm]
20
[508 mm]
15
[381 mm]
30
[762 mm]
66
[1676 mm]
86
[2184 mm]
4
[102 mm]
5
[127 mm]
15 1/8
[384 mm]
8
[202 mm]
6 7/8
[210 mm]
43 3/8
[1101 mm]
ADJUSTABLE FROM 73 1/2 TO 76
[1867 mm TO 1930 mm]
25 1/4
[642 mm]
25
[635 mm]
CLEARANCE
(HIGH HOOD)
34 1/4
[870 mm]
TABLE HEIGHT
8
[202 mm]
73 3/4
[1873 mm]
11 3/4
[297 mm]
4 MIN
[102 mm]
19 3/4
[502 mm]
CLEARANCE
(STANDARD)
62 1/4
[1581 mm]
68 1/2
[1740 mm]
68 1/8
[1730 mm]
A
A
B
A B
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4 [6 mm]
per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
6
07610-004-33-05-E
8
[202 mm]
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4 per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
A - Electrical Connection
B - Water Inlet
(1/2" NPT, 110 °F MIN (27 kW Booster))
C - Drain Connection
(1 1/2" NPT)
D - Vent Connections
(Including Dampers)
E - Energy Recovery Water Inlet
(1/2" NPT, 55 °F MIN)
increased 1 3/4" using the machine’s
adjustable feet.
Items in red are not supplied with the
machine.
LEGEND
Primary Electrical Opening
(Provided on both ends of machine.)
Secondary Electrical Opening
(Provided on both ends of machine.)
Single-point (Option): uses only
primary opening to power the
entire machine.
Dual-point (Standard): also uses
secondary opening for a
separate connection to
only the booster.
34 1/4
[870 mm]
TABLE HEIGHT
89 1/8
[2264 mm]
All dimensions from the floor can be
- High Hood Option
- Open Door
SPECIFICATIONS
44" ENERGY RECOVERY DIMENSIONS
44" LEFT-TO-RIGHT
07610-004-33-05-E
7
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4 per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
Primary Electrical Opening
(Provided on both ends of machine.)
Secondary Electrical Opening
(Provided on both ends of machine.)
Single-point (Option): uses only
primary opening to power the
entire machine.
Dual-point (Standard): also uses
secondary opening for a
separate connection to
only the booster.
34 1/4
[870 mm]
TABLE HEIGHT
A - Electrical Connection
B - Water Inlet
(1/2" NPT, 110 °F MIN (27 kW Booster))
C - Drain Connection
(1 1/2" NPT)
D - Vent Connections
(Including Dampers)
E - Energy Recovery Water Inlet
(1/2" NPT, 55 °F MIN)
increased 1 3/4" using the machine’s
adjustable feet.
Items in red are not supplied with the
machine.
LEGEND
All dimensions from the floor can be
- High Hood Option
- Open Door
89 1/8
[2264 mm]
SPECIFICATIONS
44" ENERGY RECOVERY DIMENSIONS
44" RIGHT-TO-LEFT
8
07610-004-33-05-E
34 1/4
[870 mm]
TABLE HEIGHT
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4 per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
Primary Electrical Opening
(Provided on both ends of machine.)
Secondary Electrical Opening
(Provided on both ends of machine.)
Single-point (Option): uses only
primary opening to power the
entire machine.
Dual-point (Standard): also uses
secondary opening for a
separate connection to
only the booster.
A - Electrical Connection
B - Water Inlet
(1/2" NPT, 110 °F MIN (27 kW Booster))
C - Drain Connection
(1 1/2" NPT)
D - Vent Connections
(Including Dampers)
E - Energy Recovery Water Inlet
(1/2" NPT, 55 °F MIN)
increased 1 3/4" using the machine’s
adjustable feet.
Items in red are not supplied with the
machine.
LEGEND
All dimensions from the floor can be
- High Hood Option
- Open Door
89 1/8
[2264 mm]
SPECIFICATIONS
66" ENERGY RECOVERY DIMENSIONS
66" LEFT-TO-RIGHT
07610-004-33-05-E
9
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4 per ft.
Must Install
Machine Drain
Line above
3 [76 mm] MIN
Floor Drain
or Sink
1 1/2
[38 mm]
MIN
Air-gap
Primary Electrical Opening
(Provided on both ends of machine.)
Secondary Electrical Opening
(Provided on both ends of machine.)
Single-point (Option): uses only
primary opening to power the
entire machine.
Dual-point (Standard): also uses
secondary opening for a
separate connection to
only the booster.
A - Electrical Connection
B - Water Inlet
(1/2" NPT, 110 °F MIN (27 kW Booster))
C - Drain Connection
(1 1/2" NPT)
D - Vent Connections
(Including Dampers)
E - Energy Recovery Water Inlet
(1/2" NPT, 55 °F MIN)
increased 1 3/4" using the machine’s
adjustable feet.
Items in red are not supplied with the
machine.
LEGEND
All dimensions from the floor can be
- High Hood Option
- Open Door
89 1/8
[2264 mm]
SPECIFICATIONS
66" ENERGY RECOVERY DIMENSIONS
66" RIGHT-TO-LEFT
10
07610-004-33-05-E
SPECIFICATIONS
SIDE-LOADER DIMENSIONS
23”
29”
30 5/16”
23”
29”
30 5/16”
16 3/8” 16 3/8”
10”
34” ± 1”
10”
22” 22”
Adjustable Ventilation
Duct Adapter
Side-loader
Drain Hose
23" L-R UNHOODED
SIDE-LOADER
23" R-L UNHOODED
SIDE-LOADER
Ventilation Scoop
Ventilation Scoop
Ventilation Cowl
with Cut-out for
L-R Units
Dimension is 30" for the 30”
unhooded side-loader.
Dimension is 30" for the 30”
unhooded side-loader.
Electrical
Conduit
Adjustable Ventilation
Duct Adapter
Ventilation Cowl
with Cut-out for
R-L Units
Side-loader
Drain Hose
Electrical
Conduit
34” ± 1”
07610-004-33-05-E
11
SPECIFICATIONS
STEAM BOOSTER DIMENSIONS
20
3
4
2
7
8
17
1
2
24”
14
5
8
33
1
8
8
7
8
8
5
8
S
PS
PW
C
S
W1
W2
C
10
1
8
PW
1
3
4
PS
W2
11
1
8
22”
3
3
8
19
20
1
8
28
5
8
20
1
4
W1
S
W2
PS
PW
33
11
3
8
22”
7
1
2
E
E
E
11
16
3
8
E Main Electrical Connection (7/8" Hole)
W1 Main Inlet Water Connection
(3/4" NPT, 110 °F MIN, 20 ± 5 PSI)
W2 Water Outlet Connection (3/4" NPT)
PW Water Pressure Relief Outlet (3/4" NPT)
PS Steam Pressure Relief Outlet (1" NPT)
S Steam Supply to Booster (1" NPT)
C Steam Condensate Connection (3/4" NPT)
Click here for the Steam Booster manual.
12
07610-004-33-05-E
Always refer to the machine data plate for specic electrical and water requirements.
The material provided on this page is for reference only and may change without notice.
NOTICE
i
SPECIFICATIONS
OPERATING PARAMETERS
Operating Capacity:
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Racks per Hour 223 223 223 223 223 223
Dishes per Hour 5,575 5,575 5,575 5,575 5,575 5,575
Glasses per Hour 8,028 8,028 8,028 8,028 8,028 8,028
Tank Capacity (Gallons):
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Wash Tank 25 25 25 25 25 25
Pre-wash Tank N/A 15.8 N/A 15.8 N/A 15.8
Electrical Loads:
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Wash Motor HP 3 3 3 3 3 3
Drive Motor HP 1/4 1/4 1/4 1/4 1/4 1/4
Pre-wash Motor HP N/A 2 N/A 2 N/A 2
Wash Heater kW 15 15 N/A N/A 15 15
Booster Heater kW
40º 70º
12 18*
40º 70º
12 18*
N/A N/A 27 27
5 5 5 5