  • Hello! I am an AI chatbot trained to assist you with the CMA Dishmachines 181GW Quick Setup Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
11-2016PN: 10130.00
181GW
Quick Setup
Instructions
WARNING: Electrical and plumbing
connections need to be made by a
qualified service person who will
comply with all available Federal, State
and Local Health, Electrical,Plumbing
and Safety codes.
DRAIN HOSE
1
1
STEP
FLOOR DRAIN
1"AIR GAP
Connect the drain hose to floor drain. The floor
drain must have a 1 inch air gap between drain
hose and floor drain.
BLUE
Insert tube stiffener with chemical tubing into
corresponding chemical dispensers.
3
STEP
BLUE
RED
RED
TUBE
STIFFENER
CHEMICAL
TUBING
HARD WIRE
FOUR WIRE
POWER SUPPLY
RINSE
INJECTION
110V POWER
CONNECTION
FOR DISPENSER
NEUTRAL
HOT
GROUND
DETERGENT
INJECTION
WASH
SENSOR
WATER
LINE
RINSE
SENSOR
3
2
2
STEP
Connect dishmachine to hot water source
120°F - 140°F
. Minimum temperature will remain in
wash cycle until booster heater temperature reaches
180°F
, then it will advance into rinse cycle.
11-2016
181GW
Quick Setup
Instructions
WARNING: Electrical and plumbing
connections need to be made by
a qualified service person who will
comply with all available Federal, State
and Local Health, Electrical, Plumbing
and Safety codes.
6
STEP
Level dishmachine by adjusting leveling legs.
Dishmachine must be level front and back.
5
STEP
After filling dishwasher for the first time, (CAUTION:
turn power supply off) reconnect the factory
unplugged wire to booster high-limit switch located
behind front panel.
4
STEP
If necessary adjust the temperature by turning the
adjustment stem clockwise to increase.
WASH TEMP 150°-160°
POWER
FINAL RISE TEMP 180°-195°
OFF ON
DRAIN FILL
START
CYCLE
CHEMICAL
PUMPS
POWER
DRAIN & FILL
CYCLE
THERMOSTAT
BOOSTER
HIGH LIMIT
SWITCH
5
4
RINSE
PRESSURE
GAUGE
LEVELING LEGS
6
NOTE: To prevent Heating Element
damage, the 181GW heater must be
filled with water before the heating
element is energized. For this reason
the High Liimit Switch has
intentionally been disconnected at
the factory and will require
re-connection.
5
The Spirit of Excellence