Lutron Electronics Energi Savr Node QS QSNE-4S10-D Programming Manual

Type
Programming Manual

Lutron Electronics Energi Savr Node QS QSNE-4S10-D is a lighting control device designed to automate lighting based on occupancy, daylight, and manual control. It features four independent lighting zones, each of which can be programmed to respond to wired occupancy and daylight sensors, as well as infrared (IR) remote commands. The device also includes a contact closure input that can be used to force all zones on in an emergency.

Lutron Electronics Energi Savr Node QS QSNE-4S10-D is a lighting control device designed to automate lighting based on occupancy, daylight, and manual control. It features four independent lighting zones, each of which can be programmed to respond to wired occupancy and daylight sensors, as well as infrared (IR) remote commands. The device also includes a contact closure input that can be used to force all zones on in an emergency.

Contents Page
Out of Box Functionality ............................................2
Programming ............................................................3
Input Programming Mode .........................................3
Sensor Overview ......................................................3
Advanced Button Programming ................................4
Scene Programming Mode .......................................4
QS Link Input(s) Setup ..............................................6
Contact Information ..................................................8
Energi Savr NodeTM QS
Programming Guide
Model: QSNE-4S10-D
Energi Savr NodeTM QS | Programming Guide
Energi Savr NodeTM QS
|
Programming Guide Lutron®
|
2
Out of Box Functionality
This section describes the default functionality that the unit will present when first installed.
Sensors:
• ConnectedtosensorgroupA:controlszones1and2.
• ConnectedtosensorgroupB:controlszones3and4.
Occupancy
• Correspondingzoneswillturnonwhentheoccupancysensorisintheoccupiedstate(closed)andoffwhenin
the unoccupied state.
Daylight
• Correspondingzoneswillturnonwhenlightsensedbyphotosensorfallsbelowthefactorypresetlevel.
• Correspondingzoneswillturnoffwhenlightsensedbyphotosensorrisesabovethefactorypresetlevel.
IR
• ZonesrespondtoOn,Off,andScenecommandstotheLutron® IR receiver from compatible IR transmitters
(see IR Sensor literature for compatible transmitters).
QS Wallstations
• AllseeTouch® QS wallstations are Scene keypads by default.
• Scenes1-16willturnallthelightsOn.
• SceneOffwillturnallthelightsOff.
Contact Closure Input (CCI)
• TheCCIbehavesasanEmergencyContactClosureInput.
• IftheCCIisopen,theEnergi Savr NodeQSunitwillenterEmergencyMode,whichwillturnonallloadsand
disablelocalzonecontrolandcontrolfromsensorsandQSdevices.
• WhentheCCIisclosedorjumpered,Energi Savr NodeQSunitzoneswillreturntothesettingsorlevelsthey
were at prior to entering Emergency Mode.
Troubleshooting and Maintenance Features
• Afterinstallation,eachzonebuttonwilltogglethezonebetweenonandoff.
• SensorstatusLEDs(‘Occ’,‘Photo’,and‘IR’)verifyconnectionstocontrolstationsandsensors.
Normal Mode Operation
• Zonebuttons—Usedtotogglezoneonandoff.
Mains
Wiring
QS
Link
Contact
Closure
Input
Sensor
Inputs
Group A
Sensor
Inputs
Group B
Input power and switched
outputs to zones
Zone
1
Zone
2
Zone
3
Zone
4
PELV
Energi Savr NodeTM QS | Programming Guide
Energi Savr NodeTM QS
|
Programming Guide Lutron®
|
3
Programming
The out-of-box settings of an Energi Savr NodeQSunitcanbechangedtocustomizetheinstallation.Please
followthestepsdescribedbelowtoadjustthesettingsonyourEnergi Savr Node QS unit.
Input Programming Mode
*Note:After10minuteswithoutactivityontheuserinterface,theEnergi Savr Node QS unit will automatically
exit the Input Programming Mode. The Energi Savr Node QS unit will retain the latest changes.
Assign/Unassign zones to wired sensors
1.ToenterInputProgrammingMode,pressandholdtheProgrambuttonfor3seconds.The‘Program’LEDwill
blink.
2. Press Program button to sequence through each sensor input. The LED corresponding to the selected
sensor input will blink. If powered by the Energi Savr NodeQSunit,thesensorwillashalso.*
3.Foreachdesiredzone,press&holdtheZone button until the LED changes state to assign or un-assign that
zone.Ablinking‘Zone’LEDindicatesthatazoneisassigned.
4.ToexitInputProgrammingMode,pressandholdtheProgram button for 3 seconds.
Note:Beforeassigningadaylightsensortoazone,youmustrstunassociateanypreviouslyassignedsensors
fromthatzone,includingthoseinout-of-boxmode.
* Only sensors powered directly from the Energi Savr NodeQSunitwillash.
Sensor Overview
Occupancy Sensors
Energi Savr Node QS units are programmable to turn lights on and off based on room occupancy detected by
compatible occupancy sensors. To ensure proper operation of the Energi Savr Node QS unit:
• Wirenomorethan2occupancysensorstoanyoneOccconnection.An auxiliary power supply must be used
if the device(s) require(s) more than 50 mA.
Daylight Sensors
Energi Savr Node QS units are programmable to turn lights on and off based on daylight detected by
compatible Lutron® daylight sensors. To ensure proper operation of the Energi Savr Node QS unit:
• UseonlyLutrondaylightsensors(EC-DIR-WH).
• OnlywireonesensortoasinglePhotoinput.
EachzoneoutputonanEnergi Savr Node QS unit can be programmed to respond to a single daylight sensor.
Thetargetsetpointforturn-on/turn-offisadjustableforeachzone—onesensormaybelinkedtomultiple
zones,eachzonewithitsownuniquesetpoint.Pleasenotethat:
• AdaylightsensorwiredtoanEnergi Savr NodeQSunitcanbeassignedtocontrolanyorallzonesonthat
Energi Savr Node QS unit.
• Daylightsensorswillnotturnazoneonifanoccupancysensorassignedtothatzonedetectsthattheroomis
vacant.
Energi Savr NodeTM QS | Programming Guide
Energi Savr NodeTM QS
|
Programming Guide Lutron®
|
4
Please refer to the daylight sensor installation guide for details on sensor placement.
Infrared (IR) Remote Receivers
Energi Savr Node QS units are programmable to turn lights on and off based on signals provided by
compatible Lutron® IR transmitters and received by compatible Lutron IR receivers. To ensure proper operation
of the Energi Savr Node QS unit:
• UseonlyLutronIRreceivers(EC-DIR-WH,EC-IR-WH,CC-1BRL-WH,CC-4BRL-WH)
• SeeLutron IR receiver literature for compatible IR transmitters.
• OnlywireonereceivertoasingleIRinput
Advanced Button Programming
Each Energi Savr Node QSunitzonehasseveralparametersthatcanbesetoradjusted.Followthesteps
belowtoadjustazone’ssetting.
Configure Zone Parameters
1. Simultaneously press and hold the Program and Inputbuttonsfor3secondstoenterZoneSet-upMode.
‘Program’andGroupALEDswillashrapidly.
2. Press Zonebuttontoselectthezoneforwhichyouwishtosetparameters.
3.UsetheOptionbuttontoselectaparametertosetoradjustaslistedbelow.TheoptionLEDswillturnonto
indicate your selection:
Option LED(s) Parameter Method
‘Def’
SetzonetorespondtowiredOccupancy
sensor as either Occupancy or Vacancy
sensor
Usethe and buttons to select response mode.
·‘H’LEDindicatesOccupancymode(Autoon/off).
·‘M’LEDindicatesVacancymode(Manualon/
auto off)
‘Opt1’
Set daylight sensor setpoint for each
zone
Usethe button to increase the set point.
Usethe button to decrease the set point.
4.Repeatsteps2and3foreachdesiredzone.
5. Simultaneously press and hold the Program and Inputbuttonsfor3secondstoexitZoneSet-upMode.
Scene Programming Mode
Scene Programming
EachoutputzoneontheEnergi Savr Node QS unit has 16 scenes plus Off. Each scene can be programmed
toturnthezoneonoroff,orthezonecanbesettobeunaffectedinascene,sothatchangingtothatscene
willnotchangetheunaffectedzonefromitscurrentlevel.Note:SceneOffcannotbemodied.
Follow the steps below and in the QS Link Input(s) Set-up section.
Scenes 1-4
1. Simultaneously press and hold the Program and Option buttons on the Energi Savr Node QS unit for 3
secondstoenterSceneProgrammingMode.‘Program’andGroupBLEDswillashrapidly.
2.UsetheOptionbuttontoselectascenetodeneforeachzone.OptionLEDwillbesteadyon,toindicate
current scene selected:
LED Legend: = steady on = flashing = off
LEDs Scene # LEDs Scene # LEDs Scene # LEDs Scene #
Scene 1 Scene 2 Scene 3 Scene 4
3.Usethe and buttonstosettheselectedscenetoOnorOff.The‘H’,‘M’,and‘L’LEDgroupindicatesyour
choice: all LEDs on = On; all LEDs off = Off.
4.Tomakeazoneunaffected,pressandholdthe buttonuntilonlythe‘M’LEDturnson.
Energi Savr NodeTM QS | Programming Guide
Energi Savr NodeTM QS
|
Programming Guide Lutron®
|
5
5. Exit Scene Programming Mode: Press and hold the Program and Option buttons for 3 seconds.
Scenes 5-16
1. Simultaneously press and hold the Program and Option buttons on the Energi Savr Node QS unit for 3
secondstoenterSceneProgrammingMode.‘Program’andGroupBLEDswillashrapidly.
2. Press and hold the Option button on the Energi Savr Node QS unit for 10 seconds to access Scenes 5-16.
SceneselectionsareindicatedbyashingOptionLEDsasshownionthechartbelow:
LED Legend: = steady on = flashing = off
LEDs Scene # LEDs Scene # LEDs Scene # LEDs Scene #
Scene 5 Scene 6 Scene 7 Scene 8
Scene 9 Scene 10
Scene 11
Scene 12
Scene 13
Scene 14
Scene 15 Scene 16
3.Usethe and buttonstosettheselectedscenetoOnorOff.The‘H’,‘M’,and‘L’LEDgroupindicatesyour
choice: all LEDs on = On; all LEDs off = Off.
4.Tomakeazoneunaffected,pressandholdthe buttonuntilthe‘Zone’LEDturnsoffandthe‘M’LEDturns
on.
5.Ifnecessary,youmaypressandholdtheOption button on the Energi Savr Node QS unit for 10 seconds to
return to Scenes 1-4.
6. Exit Scene Set-up Mode: Press and hold the Program and Option buttons for 3 seconds.
Energi Savr NodeTM QS | Programming Guide
Energi Savr NodeTM QS
|
Programming Guide Lutron®
|
6
QS Link Input(s) Setup
To assign a seeTouch®QSWallstationorGRAFIKEye® QS unit to any Energi Savr NodeQSunitzoneonthe
QSlink,followthestepsbelow.
seeTouch QS Wallstation - Scenes and Scenes + Off
1. Simultaneously press and hold the top and bottom buttons on the wallstation for 3 seconds. The QS link
entersProgrammingMode.ThesensorGroupAandGroupBLEDsandthe‘H’,‘M’,and‘L’LEDsonthe
Energi Savr NodeQSunit(s)willashsequentiallyingroups.
2.UsetheOption button to select the scene wallstation type. A blinking LED indicates the selection:
•‘Def’LEDindicatesa‘scene+off’wallstation(wallstationhasaspecicOffbutton)
•‘Opt1’LEDindicatesa‘scene’wallstation(wallstationhasnoOffbutton)
3.Tosavethewallstationtype,pressandholdtheOption button for 3 seconds. The LED for the selected
wallstationtypewillutterfor1second,thenremainsteady.
4.Toassigndesiredzone(s)toawallstation,pressandholdtheZonebuttonforeachdesiredzonefor
3seconds.Ablinking‘Zone’LEDindicatesanassignedzone.
5. Simultaneously press and hold the top and bottom buttons on the wallstation for 3 seconds to save the
settings.
To un-assign Energi Savr NodeQSunitzonesfromaspecicwallstation,pressandholdtheZone button for
theassignedzone(s)for3seconds.The‘Zone’LEDwillturnofftoindicatesuccess.
Repeatforeachdesiredwallstation-to-zoneset-upthatyouwishtoun-assign.
seeTouch QS Wallstation - Zone Toggle Type
1. Simultaneously press and hold the top and bottom buttons on the wallstation for 3 seconds. The QS link
entersProgrammingMode.ThesensorGroupAandGroupBLEDsandthe‘H’,‘M’,and‘L’LEDsonthe
Energi Savr NodeQSunit(s)willashsequentiallyingroups.
2.UsetheOptionbuttontochangethewallstationtypetozonetoggle.AblinkingLEDwillindicatetheselection.
Select‘Opt2’.
3.Tosavethewallstationtype,pressandholdtheOption button for 3 seconds. The LED for the selected
wallstationtypewillutterfor1second,thengotoanonstate.
4. To assign a specific wallstation button(s) to an Energi Savr NodeQSunitzone,pressthewallstationbuttonyou
wish to assign (e.g. press button 1 – LED blinks slowly).
5. Press and hold the Zonebuttonforthedesiredzonefor3seconds.Ablinking‘Zone’LEDindicatesan
assignedzone.
6.Repeatsteps4-5foreachdesiredbutton-to-zoneassignment.
7. Simultaneously press and hold the top and bottom buttons on the wallstation for 3 seconds to save the
settings.
To un-assign Energi Savr NodeQSunitzonesfromspecicwallstationbuttons,pressandholdtheZone
buttonfortheassignedzone(s)for3seconds.The‘Zone’LEDwillturnofftoindicatesuccess.
GRAFIK Eye QS unit - Scenes and Scenes + Off
1. Simultaneously press and hold the top and bottom scene buttons on the GRAFIK Eye QS unit for 3 seconds.
TheQSlinkentersProgrammingMode.ThesensorGroupAandGroupBLEDsandthe‘H’,‘M’,and‘L’LEDs
on the Energi Savr NodeQSunit(s)willashsequentiallyingroups.
2.Toassigndesiredzone(s)toaGRAFIK EyeQSunit,pressandholdtheZonebuttonforthedesiredzonefor3
seconds.Ablinking‘Zone’LEDindicatesanassignedzone.
3. Simultaneously press and hold the top and bottom scene buttons on the GRAFIK Eye QS unit for 3 seconds to
save the settings.
Energi Savr NodeTM QS | Programming Guide
Energi Savr NodeTM QS
|
Programming Guide Lutron®
|
7
QSE-IO Association - Scene DIP configuration
The Energi Savr Node QS unit can be associated to a QSE-IO (contact closure interface) that is set in a Scene
DIP configuration. This can be used to change scenes on your Energi Savr Node QS unit from third party
equipment(usingcontactclosureinputsintotheQSE-IO),ortomonitorscenechangesonyourEnergi Savr
Node QS unit from third party equipment (using contact closure outputs out of the QSE-IO). Consult the QSE-
IO instructions for proper DIP configuration.
To associate a QSE-IO that is set in a Scene DIP configuration to an Energi Savr NodeQSunit(s),followthe
steps below:
1. Press and hold the Program button on the QSE-IO for 3 seconds to enter Programming Mode. The 5 output
LEDswillcycle.ThesensorGroupAandGroupBLEDsandthe‘H’,‘M’and‘L’LEDsontheEnergi Savr Node
QSunit(s)willashsequentiallyingroups.
2.Toassigndesiredzone(s)totheQSE-IO,pressandholdtheZone button on the Energi Savr Node QS unit for
eachdesiredzonefor3seconds.Ablinking‘Zone’LEDindicatesanassignedzone.
3.ToexitProgrammingMode,pressandholdtheProgram button on the QSE-IO for 3 seconds.
Toun-assignzonesfromtheQSE-IO,pressandholdtheZone button on the Energi Savr Node QS unit for 3
seconds.The‘Zone’LEDwillturnofftoindicatesuccess.
Repeatforeachzonethatyouwishtoun-assignfromtheQSE-IO.
QSE-IO Association - Zone Toggle and Occupancy DIP configurations
The Energi Savr Node QS unit can also associated to a QSE-IO (contact closure interface) that is set in the
ZoneToggleorOccupancyDIPconguration.IntheZoneToggleconguration,thiscanbeusedtotoggle
zonesonyourEnergi Savr Node QS unit from third party equipment (using contact closure inputs into the
QSE-IO),ortomonitorthestate(onoroff)ofthezonesonyourEnergi Savr Node QS unit from third party
equipment(usingcontactclosureoutputsoutoftheQSE-IO).IntheOccupancyconguration,thiscanbe
usedtoassociateadditionaloccupancysensorstothezonesonyourEnergi Savr Node QS unit (to turn lights
on and off based on room occupancy). Consult the QSE-IO instructions for proper DIP configuration.
ToassociateaQSE-IOthatissetinaZoneToggleorOccupancyDIPcongurationtoanEnergi Savr Node QS
unit(s),followthestepsbelow:
1. Press and hold the Program button on the QSE-IO for 3 seconds to enter Programming Mode. The first
outputLEDwillashindicatinginput1isselected.ThesensorGroupAandGroupBLEDsandthe‘H’,‘M’
and‘L’LEDsontheEnergi Savr NodeQSunit(s)willashsequentiallyingroups.
2.Toassigndesiredzone(s)toinput1oftheQSE-IO,pressandholdtheZone button on the Energi Savr Node
QSunitforeachdesiredzonefor3seconds.Ablinking‘Zone’LEDindicatesanassignedzone.
3. Press and release the Program button on the QSE-IO to select the next input. Repeat step 2 for the remaining
inputs on the QSE-IO.
4.ToexitProgrammingMode,pressandholdtheProgram button on the QSE-IO for 3 seconds.
Toun-assignzonesfromtheQSE-IOinputs,pressandholdtheZone button on the Energi Savr Node QS unit
for3seconds.The‘Zone’LEDwillturnofftoindicatesuccess.
Repeatforeachzonethatyouwishtoun-assignfromitsrespectiveQSE-IOinput.
World headquarters
LutronElectronicsCo.,Inc.
7200SuterRoad,Coopersburg,PA
18036-1299USA
TEL+1.610.282.3800
FAX+1.610.282.1243
Technical Support 1.800.523.9466
Toll-Free1.888.LUTRON1
European headquarters
UnitedKingdom
Lutron EA Ltd.
6SovereignClose,London,E1W
3JFUK
TEL+44.(0)20.7702.0657
FAX+44.(0)20.7480.6899
Technical support
+44.(0)20.7680.4481
FREEPHONE0800.282.107
Asian headquarters
Singapore
Lutron GL Ltd.
15HoeChiangRoad,
#07-03EuroAsiaCentre,
Singapore 089316
TEL+65.6220.4666
FAX+65.6220.4333
Technical hotlines
France: 0800.90.12.18
Germany: 00800.5887.6635
Italy: 800.979.208
Spain: 900.948.944
Northern China: 10.800.712.1536
Southern China: 10.800.120.1536
HongKong:800.901.849
Singapore: 800.120.4491
Taiwan: 00.801.137.737
Thailand: 001.800.120.665853
OtherAreasinAsia:+65.6220.4666
LutronElectronicsCo.,Inc.
7200 Suter Road
Coopersburg,PA18036
Lutron,GRAFIKEye,seeTouch,andthesunburstlogoare
registered trademarks and Energi Savr Node is a trademark of
Lutron Electronics Co. Inc.
©05/2010LutronElectronicsCo.,Inc.
MadeandprintedintheU.S.A.
P/N 032-311 Rev. B
Contact Information
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Lutron Electronics Energi Savr Node QS QSNE-4S10-D Programming Manual

Type
Programming Manual

Lutron Electronics Energi Savr Node QS QSNE-4S10-D is a lighting control device designed to automate lighting based on occupancy, daylight, and manual control. It features four independent lighting zones, each of which can be programmed to respond to wired occupancy and daylight sensors, as well as infrared (IR) remote commands. The device also includes a contact closure input that can be used to force all zones on in an emergency.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI