ABLE Kamstrup 382M Installation & Maintenance Instructions

Type
Installation & Maintenance Instructions

ABLE Kamstrup 382M is a versatile and reliable electricity meter. It can be used for measuring electrical energy and can be configured to display various readings, including active energy consumption, voltage, and current. The meter also has a built-in LCD display and a push button that allows users to manually change the display reading. Additionally, the meter has an optical interface and an LED that blinks proportionally to the consumed active energy. The meter is designed to be secure and can only be used by authorized personnel.

ABLE Kamstrup 382M is a versatile and reliable electricity meter. It can be used for measuring electrical energy and can be configured to display various readings, including active energy consumption, voltage, and current. The meter also has a built-in LCD display and a push button that allows users to manually change the display reading. Additionally, the meter has an optical interface and an LED that blinks proportionally to the consumed active energy. The meter is designed to be secure and can only be used by authorized personnel.

Installation & Maintenance Instructions
Kamstrup 382M
Reading Office
Cutbush Park, Danehill, Lower Earley,
Reading, Berkshire. RG6 4UT. UK.
Tel: +44 (0)118 9311188
Aberdeen Office
Unit 6 Airside Business Park, Kirkhill Industrial Estate,
Dyce, Aberdeen. AB21 0GT. UK.
Tel: +44 (0)1224 725999
Internet: www.able.co.uk
e-procurement: www.247able.com
Registered in England No: 01851002
VAT No: GB 417 2481 61
2
55121131_B1_GB_10.2013
Installation manual
Connect the meter in accordance with the installation diagram on the meter’s type label.
Depending on the configuration a fixed value will be displayed, or the display will change
between selected indications every 10 seconds.
It is possible to change the display reading manually by activating the push button on the
meter. The available readings will depend on the meter’s configuration.
Security and installation guidelines
The meter is only to be used for measuring electrical energy and shall operate within the
specified values only.
The meter must be disconnected when working on it. It can be highly dangerous to touch the
meter parts when the meter is switched on.
Therefore, the relevant security fuse must be removed and kept in a place where it cannot be
inserted by unauthorized persons.
Current local standards, guidelines, regulations and instruction must be observed. Only
authorized personnel is permitted to install electricity meters.
Meters for direct connection must be protected against short circuit by a security fuse in
accordance with the maximum current stated on the meter.
LCD-display
Optical interface
LED (meter constant)
LED breaker status
(only meters with
internal breaker)
Push button
(not used)
Utility seals
Type label
Secondary module
Push button
The meter constant LED blinks proportionally to the consumed active energy.
Only authorized personnel must break the utility sealing.
3
55121131_B1_GB_10.2013
Installation manual
The phase indications have various functions. They indicate the two situations described below.
From the connection of the meter:
Indications L1, L2, L3 Indicate
On Voltage is above minimum limit (160V)
Off Voltage is below minimum limit (160V)
Indications
Indicate
On The load is above the minimum (2.3W)
Off The load is below minimum limit (2.3W)
If the load exceeds the minimum limit and the meter is configured with this reading,
consumption will be indicated via the quadrant reading. The direction of the three phase
currents is indicated via the arrows above, respectively L1, L2 and L3.
7-digit identification field
Quadrant indicator
Module indication
Text field
Unit field
Breaker symbol
Tamper symbol
Tariff indication
Radio network symbol
Error symbol
Phase sequence indication
9-digit value field
Phase current indication
Prepayment-symbol
Supply voltage indication
For future use
For future use
For future use
For future use
For future use
Terminals
Multi core 7 core Massive / terminals
35 mm
2
6 mm
2
6 mm
2
2.5 mm
2
Screw: Pz 2 or straight slot
Torch: 2.5 – 3 Nm
Load control, installation
For meters with load control relay(s). Due to the delay in the meter, it is important to restart the
meter (off/on) when the time is set correctly in the meter. This places the relays in the correct
position and stops the delay timer.
4
55121131_B1_GB_10.2013
Installation manual
With built-in radio
If the meter is supplied with integral radio for establishment of remote reading, the meter
automatically connects to a radio network. The integral radio is equipped with an internal
antenna. The radio signal strength can be read by means of a hand-held terminal. If the
radio signal is not sufficient, an external antenna must be connected. Please see current
documentation on available antennas.
Mounting a communication module in the meter may influence on radio communication, please
contact Kamstrup.
With disconnection function
With this type of meter, it must be checked that the red diode is not switched on. This indicates
that the consumer’s supply is switched off.
Installation dimensions
171.7
269.2
80.3
Connection diagrams
The valid connection diagram appears from the type label.
1 2 3 4 5 6
7 8 9 10 11 12
L1
L2
L3
N
S0
+
20
-
21
P+
1 2 3 4 5 6
7 8 9 10 11 12
L1
L2
L3
N
S0
+
20
-
21
P+
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

ABLE Kamstrup 382M Installation & Maintenance Instructions

Type
Installation & Maintenance Instructions

ABLE Kamstrup 382M is a versatile and reliable electricity meter. It can be used for measuring electrical energy and can be configured to display various readings, including active energy consumption, voltage, and current. The meter also has a built-in LCD display and a push button that allows users to manually change the display reading. Additionally, the meter has an optical interface and an LED that blinks proportionally to the consumed active energy. The meter is designed to be secure and can only be used by authorized personnel.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI