Lithonia Lighting RT8R Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Lithonia Lighting RT8R Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Instructions
RT8RT/RT5RT Relight Assembly
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER
AFTER INSTALLATION.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT
IN DEATH, SERIOUS INJURY OR SIGNIFICANT PROPERTY DAMAGE. For your protection,
read and follow these warnings and instructions carefully before installing or maintaining this equipment. These
instructions do not attempt to cover all installation and maintenance situations. If you do not understand these
instructions or additional information is required, contact Acuity Brands Lighting or your local Acuity Brands
Lighting distributor.
WARNING: RISK OF ELECTRIC SHOCK. Never connect to, disconnect from or service while circuit
equipment is energized.
WARNING: RISK OF FIRE. Lamps are hot. Keep combustible materials away from hot parts. Observe
lamp manufacturer’s warnings, recommendations and restrictions on lamp operation and maintenance. Make
sure lamps are correctly installed. Use supply conductors with a minimum insulation temperature rating as
specified on equipment.
WARNING: Do not use abrasive materials, glass cleaners or other solvents on reflector or lens. Use of these
substances may damage fixture, which may result in personal injury.
WARNING: RISK OF PERSONAL INJURY. This equipment may have sharp edges. Wear gloves to
prevent cuts or abrasions when removing from carton, handling and maintaining this equipment.
Do not install a damaged fixture.•
This equipment must be installed in accordance with all applicable installation codes and ordinances.•
Proper grounding is required to ensure personal safety.•
All service shall be performed by qualified service personnel. This equipment must be installed and •
maintained in accordance with all applicable installation codes by a person familiar with the construction
and operation of this product and any hazards involved.
CAUTION: Observe lamp manufacturer’s recommendations and restrictions on lamp operation, including
but not limited to ballast type, burning position, replacement and cycling. We recommend only lamps that
comply with applicable ANSI standards.
All fluorescent lamps contain mercury. Follow disposal laws. See www.lamprecycle.org or contact your state
environmental protection department for more information.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or
handling of this product.
SAVE THESE INSTRUCTIONS
Acuity Brands Lighting, Inc.
One Lithonia Way
Conyers, GA 30012
770-922-9000
U21299
REV. A
11/23/2009
DISCONTINUED
Class R Type II Reflector Retrofit Kit
Installation Instructions for Fixture Conversion Retrofit Classified by Underwriters Laboratories, Inc.
Reflector Kit Type II: Reflector installation or replacement
Lamp holder relocation, removal or replacement
Ballast relocation, removal, replacement or addition
Installation Instructions
The installation of the Class R reflector kit Type II shall be performed by qualified personnel by completing the steps listed
below.
This retrofit kit will consist of:
(1) end bracket/ballast assembly prewired with ballast and sockets mounted (ballast will be Class P with UL approvals
and wiring diagram on label)
(1) splice box
(2) reflectors
(1) trim assembly and mounting hardware consisting of:
(2) quarter-turn fasteners
(60) #8 self-drilling TEK screws
Job packs will have screws bulk-packed with each pallet of kits.
Verify the contents of the retrofit kit by using the diagram below.
End Brackets/Splice Box Reflectors Trim
DISCONTINUED
Step One:
Remove existing components from host fixture.
Locate the fluorescent lighting fixture that is to be retrofitted. Turn off power.
WARNING: Electrical shock can occur during retrofit component installation if power is not turned off.
WARNING: Installation of this retrofit assembly requires a person familiar with the construction and operation of
fluorescent luminaire electrical system and the hazard involved.
WARNING: Unless otherwise indicated, do not make or alter any opening in the compartment of wiring or electrical
components during installation of this retrofit assembly.
WARNING: Ensure that existing fixture is and remains properly connected to building ground.
Use of any other than Lithonia Lighting supplied screws to install assembly may result in ungrounded fixture
components.
Remove existing louver, lamps and channel cover. Identify power supply wires to disconnect. Follow installation step
2 wiring option A or B based on incoming supply wire. Remove ballast, sockets and lampholder bracket. Recycle or
properly dispose of all components removed from host fixture.
Step Two:
Install relight assembly.
Install end brackets to 2’ length (socket side) of fixture. Install end bracket assembly by inserting bottom flange between
bottom of fixture end plate and tee-bar. Center end bracket and attach using two 8-32 self-drilling TEK screws through
the small holes at the top of the bracket (provided). Repeat on opposite end of fixture as shown.
DISCONTINUED
Optional Step:
Option A: Fixture Supply wire
is (2) #18AWG solid
1) Remove splice to existing
ballast.
2) Connect #18AWG black
and white to RT8RT/RT5RT
ballast disconnect.
Option B: Fixture supply wire
is any other than (2) #18 AWG
solid
1) Cut ballast input leads 6 "
from splice, and strip lead to
3/8”.
2) Connect #18 AWG black
and white (old ballast input
lead) to RT8RT/RT5RT ballast
disconnect.
3) Install splice box to cover
input wire splice, using two
TEK screws.
TEK SCREWS
BRACKET
END
FLANGE SITS ON T-BAR
BENEATH FIXTURE
BDP
TEK SCREW TEK SCREW
TEK SCREWS
BDP
BENEATH FIXTURE
FLANGE SITS ON T-BAR
END
BRACKET
TEK SCREWS
BDP
END
BRACKET
END
BRACKET
BDP
OLD BALLAST INPUT LEADS
TEK SCREWS
BRACKET
END
FLANGE SITS ON T-BAR
BENEATH FIXTURE
BDP
TEK SCREW TEK SCREW
TEK SCREWS
BDP
BENEATH FIXTURE
FLANGE SITS ON T-BAR
END
BRACKET
TEK SCREWS
BDP
END
BRACKET
END
BRACKET
BDP
OLD BALLAST INPUT LEADS
TEK SCREWS
BRACKET
END
FLANGE SITS ON T-BAR
BENEATH FIXTURE
BDP
TEK SCREW TEK SCREW
TEK SCREWS
BDP
BENEATH FIXTURE
FLANGE SITS ON T-BAR
END
BRACKET
TEK SCREWS
BDP
END
BRACKET
END
BRACKET
BDP
OLD BALLAST INPUT LEADS
TEK SCREWS
BRACKET
END
FLANGE SITS ON T-BAR
BENEATH FIXTURE
BDP
TEK SCREW TEK SCREW
TEK SCREWS
BDP
BENEATH FIXTURE
FLANGE SITS ON T-BAR
END
BRACKET
TEK SCREWS
BDP
END
BRACKET
END
BRACKET
BDP
OLD BALLAST INPUT LEADS
Make wire connections and ground assembly to host fixture per option A or B based on existing fixture supply wire.
Option A and B (see photos on next page)
Optional Step:
The 2RT8RT/2RT5RT Relight Assembly is shipped with two flexible reveal cover trim pieces. Some installations in
existing lensed troffers can leave unsightly gaps between the side rail of the Relight door frames and the existing
housing, which can leave old hinge and latch points exposed. The trim kit is designed to cover these to insure an
attractive installation.
To install, slide the ends of the trim piece under the Relight end brackets as shown in in the photo. When they are fully
in place, slide the notch of the trim piece towards the end bracket to fully seat the part. The part is flexible so this step
can typically be completed either before or after full installation of the Relight assembly.
DISCONTINUED
Install reflectors by inserting notched
end of the reflector past lance in end
bracket assembly and then rotating
opposite end (end accepting twist-
lock fasteners) into fixture.
Shift reflector until notches are locked
in place under lance and attach using
a quarter-turn fastener twisting tabs
that protrude through the reflectors
(spacers). Rotate second reflector
180° and repeat installation steps.
Install lamps. Use center slot in
housing to clear lamp pins.
Install trim assembly by inserting
hinge into slot of end bracket and
sliding back into the corner. Repeat
with opposite hinge, swing louver
closed and rotate latches into
locked position.
Trim hinges and latches from either side. Simply slide hinge into slot’s universal bracket assembly, close door and engage
cam latches.
Help save our environment by recycling all remaining components.
Save these instructions.
Option A and B (continued)
DISCONTINUED
/