MULTIPLEX Water Soda Switch Capacitor EI200302 Installation guide

Type
Installation guide

MULTIPLEX Water Soda Switch Capacitor EI200302

The MULTIPLEX Water Soda Switch Capacitor EI200302 is a replacement capacitor for water and soda switches. It is designed to improve the performance and reliability of these switches, and to protect them from damage. The capacitor is easy to install, and comes with all the necessary parts and instructions.

The MULTIPLEX Water Soda Switch Capacitor EI200302 is a valuable addition to any water or soda dispensing system. It can help to improve the performance and reliability of these switches, and to protect them from damage.

MULTIPLEX Water Soda Switch Capacitor EI200302

The MULTIPLEX Water Soda Switch Capacitor EI200302 is a replacement capacitor for water and soda switches. It is designed to improve the performance and reliability of these switches, and to protect them from damage. The capacitor is easy to install, and comes with all the necessary parts and instructions.

The MULTIPLEX Water Soda Switch Capacitor EI200302 is a valuable addition to any water or soda dispensing system. It can help to improve the performance and reliability of these switches, and to protect them from damage.

Manitowoc Beverage Equipment
2100 Future Drive Sellersburg, IN 47172-1868
Tel: 812.246.7000, 800.367.4233 Fax: 812.246.9922
www.manitowocbeverage.com
Foodservice Group
In accordance with our policy of continuous product development and improvement,
this information is subject to change at any time without notice.
EI200302 Revision A (KAK) 21 August, 2000
Multiplex Beverage Equipment Installation Instructions for
Replacing Capacitor on Water and Soda
Switch with MOV
Parts (per tower)
Two MOV (Metal Oxide Resistor) (P.N. 00200302)
Four 0.187 Insulated Spade Connectors (P.N. 00803401)
Instructions for replacing the
capacitor
1. Turn power switch to tower to the “off” position.
2. Optionally remove water and soda switches from the front
panel on tower, if you cannot easily get at connectors on
switches.
3. Remove connector on common (COM) terminal of switch
(black wire and one capacitor lead) (refer to Figure 1).
4. Remove connector on normally open (NO) terminal of
switch (green or white ground wire and other capacitor
lead).
5. To remove capacitor, cut both connectors as shown in Fig-
ure 2. Save the insulated tubing on each capacitor lead.
6. Re-strip the two wires and attach one lead of supplied
new metal oxide varistor (MOV) to each wire, along with
insulated tubing saved from the previous step, then crimp
inside new solderless connectors (supplied).
7. Reconnect new connector with black wire and one lead of
MOV onto the COM terminal of switch.
8. Reconnect other new connector with green or white ground
wire and other lead of MOV onto the normally open (NO)
terminal of switch.
9. Verify new installation looks like Figure 3.
10. Repeat for second switch.
11. Replace and secure switches into tower faceplate.
12. Turn power switch to the “on” position and test both
switches.
Figure 3
Figure 2
Figure 1
2
EI200302 Revision A (KAK) 21 August, 2000
Equipment Installation Instructions
Caution: To Avoid Serious Injury
Important: Read the following warnings before beginning an installation. Failure to do so
may result in possible death or serious injury.
DO Adhere to all National and Local Plumbing and Electrical Safety Codes.
DO Turn “off” incoming electrical service switches when servicing, installing, or
repairing equipment.
DO Check that all flare fittings on the carbonation tank(s) are tight. This check
should be performed with a wrench to ensure a quality seal.
DO Inspect pressure on Regulators before starting up equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges of all equipment.
DO Handle CO
2 cylinders and gauges with care. Secure cylinders properly against
abrasion.
DO Store CO2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a CO2 cylinder. Secure the cylinder(s) in an upright position
with a chain.
DO NOT Connect the CO2 cylinder(s) directly to the product container. Doing so will
result in an explosion causing possible death or injury. Best to connect the
CO2 cylinder(s) to a regulator(s).
DO NOT Store CO2 cylinders in temperature above 125°F (51.7°C) near furnaces,
radiator or sources of heat.
DO NOT Release CO2 gas from old cylinder.
DO NOT Touch Refrigeration lines inside units, some may exceed temperatures of
200°F (93.3°C).
Notice: Water pipe connections and fixtures directly connected to a potable water supply
shall be sized, installed and maintained in accordance with Federal, State, and Local codes.
  • Page 1 1
  • Page 2 2

MULTIPLEX Water Soda Switch Capacitor EI200302 Installation guide

Type
Installation guide

MULTIPLEX Water Soda Switch Capacitor EI200302

The MULTIPLEX Water Soda Switch Capacitor EI200302 is a replacement capacitor for water and soda switches. It is designed to improve the performance and reliability of these switches, and to protect them from damage. The capacitor is easy to install, and comes with all the necessary parts and instructions.

The MULTIPLEX Water Soda Switch Capacitor EI200302 is a valuable addition to any water or soda dispensing system. It can help to improve the performance and reliability of these switches, and to protect them from damage.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI