AST KAK-F User manual

Type
User manual
Load Link
KAK-F
Manual
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
Marschnerstraße 26 01307 Dresden
Phone +49(0351) 44 55 30 Fax +49(0351) 44 55 555
www.ast.de [email protected]
Manual Load Link KAK-F
11/2005 page 1
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
List of contents
1 Description ..........................................................................................................................................1
2 List of Items Supplied ........................................................................................................................1
3 Accuracy and safety...........................................................................................................................2
4 Operating of Load Link KAK .............................................................................................................2
5 Operation of Wireless Remote Control FFB 102 .............................................................................3
1 Description
Die Load Link KAK-F is a compact measuring device for the determination of loads in wire rope and
cranes.
With the assistance of shackles, hooks and master links the load link can be completed to a
crane scale.
The display of wireless remote control FFB 102 displays the load applied. The load link operates
independently of mains and its operation time with a fully charged battery
amounts to at least 100 h.
The load link KAK-F and the
wireless remote control FFB 102 communicate wireless on a pre-assigned digital
radio address. This allows the usage of many units in the same area without cross communication.
After switching on, the FFB 102 indicates the address for 2s seconds. The KAK sends out the current
load value with a transmission rate of 2 per second. After switching on of the FFB, the FFB and the KAK
synchronize itself. 8 time slots are available altogether. If a time slot is used, than another is applied.
The initial synchronisation of both devices takes 4-10 sec, if the KAK has been switched on first.
Otherwise it can take up to 20sec, due to activated the sleep mode of the FFB 102.
Always use the antenna delivered with the KAK. If the system is exposed to strong electrical fields data
transmission might be disturbed.
.
i
This equipment meets the requirements of the EC Machine Directive No 89 / 392 / EEC. It might
be used in all EU- states, but not in Great Britain and Greece.
ATTENTION! Please note that the load link is a piece of measuring equipment and not a safety device!
2 List of Items Supplied
Load link KAK
wireless remote control FFB 102
Carriage case
Battery charger for load link
Manual Load Link KAK-F
page 2 11/2005
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
3 Accuracy
i
In order to guarantee high precision of measurement, the load must always hang on the rope
vertically and without vibration. This applies also to the shackle which must be suspended in a
straight line!
ATTENTION! Excessive overload of the scale by a load of more than 150 % will result in a shift of zero
and is not permitted for safety reasons. Avoid bending and excessive torque. Handle as a
measuring instrument!
4 Operating of Load Link KAK
Switch on
Switch off (press 2 sec).
The green power-LED indicates operating state. The red low-power-LED indicates that the KAK has to be
re-charged with the battery charger plugged into the socket at the backside. The loading time is max. 16
hours. If no weight change takes place for a time interval of 10 minutes, the KAK powers off
automatically.
ON
OFF
ON
OFF
Manual Load Link KAK-F
page3
A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden
5 Operation of Wireless Remote Control FFB 102
Key Function
Display, if you press the Key
(ON)
short
Switch on the FFB 102
Switch the display modes Gross and
Net
‚brut’ Gross-display
‚nEt’ Net-display
..(OFF)
short
Switch off the FFB 102
(ON)
long
Switch the display modes
- instantaneous value
- peak hold
- ‚nEt’ or ‚brut’ than ‚nor’
- ‚nEt’ or ‚brut’ than ‚SPit’
(TARE)
short
in mode instantaneous value: taring,
i.e. resetting the display to zero / Net-
mode
in mode peak hold: re-setting the
peak hold to the actual value
‚tAr
‚C SP
(PRINT)
short
Send display value to PC (ASCII
string to RS232)
‚Prt
use cable xkc 021 and software
xks 021a for transmission
(PRINT)
long
Send display value to PC constantly
with a period of 2 sec.
‚Prt
(LIGHT)
short
Activate backlight
Description of display
Display Description
- - - - KAK switched off or
no communication to the KAK
X X X X X Gross-display
Í
X X X X X
Net-display
X X
Ã
X X X Peak hold
∩∩∩∩
Overload indication
∪∪∪∪
Under load indication
X
Ã
X
z
X
Ã
X
Ã
X Low battery indication of KAK or FFB 102
à flashing decimal point
Die FFB 102 works with non chargeable batteries. Please exchange if necessary.