AC100 HIGH-PERFORMANCE VC INVERTER MANUAL OVERVIEW
6
Protection function
Bus overvoltage, mains under voltage, inverter over-current, module failure,
inverter overload, motor overload, current detection zero drift failure, Hall
failure, E2ROM failure, motor grounding failure, input phase failure, output
phase failure, inverter overheating, communication failure, PG card failure,
PG disconnection failure, motor parameter self-tuning failure;
Special Functions
VC mode 2 modes: 1st mode providing high-performance speed effect; 2ed mode
providing lower and simple performance testing method;
Auto-learning
Asynchronous motors, synchronous motors static parameter learning,
rotation parameter learning;
Static self-learning induction motors all parameters; PG vector control
encoder self-learning;
Supporting multiple
encoders Incremental encoder (5V, 12V power supply, frequency dividing output),
resolver, SinCos encoders, absolute encoders;
VF separation
function Frequency, voltage can be independently given and regulated, supporting
multi-channel given way;
Terminals, Analog
quantity
Providing 4-way virtual X terminals, 4-way virtual Y terminals; supporting
delay adjustment of terminal rising and falling;
Extending 3-way X terminals by analog quantity;
Providing more than two points analog quantity for analog calibration;
Motor grounding
short circuit detection Can detect whether the motor is shorted to ground and the electricity can be
automatically detected;
Servo control Supporting basic functions like synchronous and asynchronous servo
control, pulse tracking, zero servo positioning servo index location,
supporting quadrature pulse given;
Telecommunication
network
supporting 485 / Modbus protocol, CANopen protocol, profibus-DP protocol;
Modbus freedom protocol, CAN custom protocols, networking and linkage
control between WEICHI inverters can be realized;
Remote and
monitoring function
Supporting remote upgrading, remote monitoring, remote locking function,
can be connected to WEICHI 3G module;
Supporting virtual oscilloscope monitoring and debugging;
Keyboard
display
LED display Single row 4 digital tube display Can monitor one state variable
Two row 5 digital tube display Can monitor two state variables
Parameter copy Function code information of frequency inverter can be uploaded and
transferred to realize fast parameter copy.
State monitoring Output frequency, given frequency, output current, input voltage, output
voltage, motor speed, PID feedback, PID given value, module temperature,
input and output terminal status
Environment
Installation site Indoor, altitude ≤1000m, no corrosive air or direct sunshine
Temperature, humidity -10 ~ +40℃ 20%~90%RH(no condensation)
Vibration Under 20Hz≤0.5g
Storage temperature -25~+65℃
Installation method Hanging type, cabinet type
Protection level IP20
Cooling method Forced air cooling