jbc CLU / CLUP Senior Tip Cleaner User manual

  • Hello! I've carefully reviewed the instruction manual for the JBC Senior Tip Cleaner, specifically models CLMU-A, CLMU-PB, CLU, and CLUP, which comes with metal and non-metal brushes. I understand its operation modes, like continuous and sensor-based cleaning, the importance of short cleaning times, and options for different sensor detection levels. I'm here to help answer your questions about how to use and maintain your device. I can also assist you with some safety information and troubleshooting options.
  • How long should the tip be placed between the brushes for cleaning?
    What does a blinking red light on the cleaner indicate?
    How can I clean the brushes?
    How can I change the sensor operation level?
CLU / CLUP
Senior Tip Cleaner with
Metal Brushes / Non-Metal Brushes
INSTRUCTION MANUAL
Senior Tip Cleaner .................................... 1 unit
AC Adapter .................................................. 1 unit
0022529
Manual ......................................................... 1 unit
0 0 274 9 6
EU US
Packing List
The following items are included:
This manual corresponds to the following references:
CLMU-A with metal brushes
CLMU-PB with HMP non-metal brushes
Brush reference according purchased cleaner
model. Brushes already installed inside the cleaner.
Metal Brushes for
CLU/CLUP & CLR ................................... 2 units
Ref. CLMU-A8
Non-Metal Brushes HMP
for CLU/CLUP & CLR ............................. 2 units
Ref. CLMU-P2
Metal Brushes
HMP
Non-Metal
Brushes
2
Features and Connections
Locking Tab
Splashguard
Feets for Vertical
Access
Power Cord
Socket ESD Connector
(connect to ESD Common
Grounding Point)
USB-B
Connector
Sensor Window
Switch Panel
Window
3
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
OK
OK
CLU
CLS
CLM
ANTISPLASH MEMBRANE
ON OFF
SWITCH
OFFON
SWITCH
Sensor
Mode
Continuous
Mode
On / Off
Led status
- White: Off
- Blue: Standby
- Green: Brushes activated
- Blinking Red: Brushes jammed
Operation
For best cleaning results, we recommend placing the tip between the two brushes for just 1 second.
Longer exposure time would lead to dewetting of tip surface causing oxidation.
If excessive pressure is applied with the tool against any of the brushes, the cleaner stops automatically
in order to protect the motors. Putting the tool out of the sensor detection area automatically
deactivates the cleaner.
CLUP is automatically switched off if the splashguard is opened during operation.
just 1 second
Keypad
4
Set Up
The CLU/CLUP allows you to choose between continuous operation and sensor operation.
The tip cleaner contains a sensor that detects when the soldering cartridge approaches the window
and automatically starts the brush rotation.
You can choose between 3 different settings for sensor operation:
Level 1 - for a short detection distance
Level 2 - for a medium detection distance (default)
Level 3 - for a long detection distance
Levels can be selected as follows:
1. Turn on the CLU/CLUP by pressing the On / Off key.
2. Push the “Sensor Mode” key until the interior light and keypad LEDs make one, two or three
blinks. The number of blinks indicates the selected level.
3. Push the sensor mode button to change to the next level. If the button is held down, the level
changes continuously to the next one until the button is released (changes from level 1 to 2, from 2
to 3 and from 3 to 1).
The level configuration is saved by the tip cleaner and will not be changed after the device is
restarted.
short
distance medium
distance
long
distance
Sensor Window Window
5
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
SFR-B
GSFR
TRA
CLR
EXTRACCIÓN
22220
EXTRACCIÓN
26842
26843
EXTRACCIÓN
26846
26847
26848
EXTRACCIÓN
26844
VERMELL
NEGRE GROC
VERMELL
BLAU
VERMELL
BLAU
BLAU
VERD
VERMELL
BLAU
VERD
VERMELL
NEGRE GROC
VERMELL
BLAU
BLAU
VERD
Lorem ipsum
SFR-B
GSFR
TRA
CLR
EXTRACCIÓN
22220
EXTRACCIÓN
26842
26843
EXTRACCIÓN
26846
26847
26848
EXTRACCIÓN
26844
VERMELL
NEGRE GROC
VERMELL
BLAU
VERMELL
BLAU
BLAU
VERD
VERMELL
BLAU
VERD
VERMELL
NEGRE GROC
VERMELL
BLAU
BLAU
VERD
Lorem ipsum
SFR-B
GSFR
TRA
CLR
EXTRACCIÓN
22220
EXTRACCIÓN
26842
26843
EXTRACCIÓN
26846
26847
26848
EXTRACCIÓN
26844
VERMELL
NEGRE GROC
VERMELL
BLAU
VERMELL
BLAU
BLAU
VERD
VERMELL
BLAU
VERD
VERMELL
NEGRE GROC
VERMELL
BLAU
BLAU
VERD
Lorem ipsum
SFR-B
GSFR
TRA
CLR
EXTRACCIÓN
22220
EXTRACCIÓN
26842
26843
EXTRACCIÓN
26846
26847
26848
EXTRACCIÓN
26844
VERMELL
NEGRE GROC
VERMELL
BLAU
VERMELL
BLAU
BLAU
VERD
VERMELL
BLAU
VERD
VERMELL
NEGRE GROC
VERMELL
BLAU
BLAU
VERD
Lorem ipsum
OK
OK
OK
CLU
CLS
CLM
ANTISPLASH MEMBRANE
ON OFF
SWITCH
OFFON
SWITCH
Locking
Tab
Changing Brushes
Before opening the tip cleaner, unplug it from the mains.
Press the brush buttons (1) to remove the brus-
hes (2).
Align the brushes with axis and push them in
until a click is heard. Check if the brushes are
properly fixed.
The CLR splashguard also works as a tin
collector. After cleaning place it back in its
position.
1
CLR
Splashguard
CLU
CLU Solder
Collection
Tray
CLR
Splashguard
1
For CLR, open the side closures and remove
the slashguard.
For CLU pull the locking tab to open the
splashguard.
CLU features a solder collection tray. After
cleaning place it back in its position.
6
CLU8 CLU7 CLUP1 / CLUP2 CLUP7 / CLUP8
Material Metal Metal Non-Metal* /
Non-Metal HMP*
Non-Metal* /
Non-Metal HMP*
Cleaning Intensive Intensive Gentle Gentle
Max. time use 10 s 10 s 5 s 5 s
Recommended
time use 1-2 s 1-2 s 1-2 s 1-2 s
Life cycle Long Long Extended Extended
Core Black Blue Black Blue
Accessories: Brush Range
*Only use the non-metal brushes when they are rotating. Incorrect use will damage them.
All brushes are offered with black and blue core, to distingish them when working with lead-free and
leaded solder.
Note: As a refereance, the cleaning process should last around 1 second.
7
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
JBC
Manager
USB Connector
JBC Updater
www.jbctools.com/software.html
Update the cleaner software via USB connection:
JBC Manager
www.jbctools.com/manager.html
Manage and monitor as many stations as your PC can handle by using the JBC Manager. You can
export data to another PC.
Download the latest software from our website to improve your CLUP.
Register Settings
Create graphs of the
soldering process in
real time with power and
temperature data.
Manager Settings
Change settings for a
group of JBC stations at
the same time.
any JBC
Station
USB
Hub
USB AB Cable
USB AB Cable JBC
Updater
8
Sensor Window
Maintenance
Before carrying out maintenance or storage, always unplug the equipment from the mains.
- Use a damp cloth to clean the splashguard outside and inside.
- Check periodically that the sensors window is clean. Use a cotton bud with alcohol to clean it.
- Maintain the brushes and the solder collection tray clean.
- Brushes (Metal- and Non-Metal Brushes ) can be cleaned by immersing them in isopropyl alcohol.
They must be allowed to dry before use.
- Replace any defective or damaged piece. Use original JBC spare parts only.
- Repairs should be performed only by a JBC authorized technical service.
9
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
Safety
- Do not use the appliance for any purpose other than tip cleaning. It is not a tool stand.
- The AC Adapter power supply must be plugged into approved bases.
- Do not leave the appliance unattended when it is running.
- Remove power cord by holding the plug, not the wire.
- Avoid contact with moving parts.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working
to avoid harm.
- This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children must not play with the appliance. Cleaning and user maintenance must not be
carried out by children without supervision.
- Utmost care must be taken with liquid tin waste which can cause burns.
- Be careful with the fumes produced when soldering.
It is imperative to follow safety guidelines to prevent electric shock,
injury, fire or explosion.
10
Specifications
CLU / CLUP
Senior Tip Cleaner with Metal Brushes / Non-Metal Brushes
Ref.: CLMU-A with metal brushes
Ref.: CLMU-PB with HMP non-metal brushes
- AC Adapter: Input: 100-240 V, 5/60 Hz
Output: DC 24 V, 2 A
- ESD safe Connector
- Ambient Operating Temperature: 10 to 40 ºC / 50 to 104 ºF
- Brush diameter: 50 mm / 2.0 in
- Cleaner Unit Dimension: 131 x 129 x 136 mm /
(L x W x H)
- Total Net Weight: 2100 g / 6.03 lb
- Package Dimensions/Weight: 220 x 213 x 160 mm / 2320g
(L x W x H) 8.70 x 5.35 x 4.96 in / 6.75 lb
Complies with CE standards.
ESD safe.
11
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
be collected and returned to an authorized recycling facility.
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
0027496-070722
/