jbc DI Reference guide

Type
Reference guide
DI
1 tool
control unit
Reference Guide
www.jbctools.com
2
DI/1 TOOL CONTROL UNIT
DESOLDERING PUMP
MS-A
DESOLDERING STAND
DR-SA
CONTROL UNIT
DI-2B / DI-1B / DI-9B
Connectable tools: T210, T245, PA120, HT420, AP130, DR560 and DS360.
Connectable modules: MS, MV and MN.
CONTENTS
Power Cord Socket
USB Connector
to PC
JBC stations intelligently manage the tool temperature:
Work mode: When the tool is used, pre-set work temperature is 350º C.
Sleep mode: When the tool is in the stand, the temperature goes down to 220º C.
Hibernation mode: After longer periods of inactivity (pre-set i.e 30 minutes), the power is cut off and the
tool cools down to room temperature.
The advantage of this heat management is lifespan increase which ensure low cost of ownership
HEAT MANAGEMENT
DI
1 tool
control unit
Reference Guide
3
Main menu
Counters
Tool settings
Exit
1 Reset settings
2
Station settings
3
Tool settings
1
Plugged hours 0
2
Working hours 0
3
Sleep hours 0
1
Fix one temp -----
2
Temp levels set OFF
3
Sleep delay 0 min
4 Counters
5
Program version
4
Hibernation hours 0
5
No tool hours 0
6 Sleep cycles
0
7 Desold cycles
0
4
Sleep temp 220
0
C
5
Hibernation delay
3
0 min
6
Temp adjust O
O
C
Tool DR
Tool DR
Back
Back
0
c
Selected temp.
350
o
C
Power 10%
350
Decrease & move down Increase & move up
Tip temperature
% Instant power supplied to the tool
ORIGINAL PIN: 0105
Station settings
1 Temp unit
Celsius
2
Maximum temp 400
0
C
3
Minimum temp 200
0
C
4
Nitrogen mode OFF
5
Help text OFF
6 Beep ON
7 Power limit 130W
8
Change PIN
Back
Access Menu
&
Confirm
Selection
WORKING
SETTINGS
WArrAntY
The JBC 2 years warranty, guarantees this equipment against all
manufacturing defects, covering the replacement of defective parts
and all necessary labour.
Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned,
postage paid, to the dealer where it was purchased enclosing this,
fully filled in, sheet.
MORE INFORMATION
www.jbctools.com
SEriAl nº
StAMP oF DEAlEr
DAtE oF PurcHASE
0008528 / 0811
TECHNICAL SPECIFICATIONS
- Temperature selection from 90 to 450°C (±5%).
- Power: 75W.
- Safety transformer, mains separator and double isolation, with temperature protection fuse.
- DI-2B 230V control unit. Input: 230V 50/60Hz. Output: 24V.
- DI-1B 120V control unit. Input: 120V 50/60Hz. Output: 24V.
- DI-9B 100V control unit. Input: 100V 50/60Hz. Output: 24V.
- Total weight of unit: 2 Kg.
- Complies with CE standards on electrical safety, electromagnetic compatibility and ESD protected housing “skin
effect”.
- RoHS compliant.
- Equipotential connector and the tool tip are connected to station mains ground supply for ESD protection.
This product should not be