H3C SR8800 Series, SR8802, SR8805, SR8808, SR8812 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the H3C SR8800 Series Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
H3C SR8800 10G Routers
Installation Guide
New H3C Technologies Co., Ltd.
http://www.h3c.com.hk
Document version: T2-080412-20170331-C-3.14
Copyright © 2007-2017, New H3C Technologies Co., Ltd. and its licensors
All rights reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior
written consent of New H3C Technologies Co., Ltd.
Trademarks
H3C, , H3CS, H3CIE, H3CNE, Aolynk, , H
3
Care, , IRF, NetPilot, Netflow,
SecEngine, SecPath, SecCenter, SecBlade, Comware, ITCMM and HUASAN are trademarks of New
H3C Technologies Co., Ltd.
All other trademarks that may be mentioned in this manual are the property of their respective owners
Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Environmental protection
This product has been designed to comply with the environmental protection requirements. The storage,
use, and disposal of this product must meet the applicable national laws and regulations.
Preface
The H3C SR8800 10G Routers Installation Guide includes seven chapters, which describe the
components, installation, debugging, and hardware maintenance of the H3C SR8800 10G Routers.
This preface includes:
Audience.
Conventions.
Obtaining documentation.
Technical support
Documentation feedback.
Audience
This documentation is intended for:
Network planners.
Field technical support and servicing engineers.
Network administrators working with the SR8800 10G Routers.
Conventions
The following information describes the conventions used in the documentation.
Command conventions
Convention Descri
p
tion
Boldface Bold text represents commands and keywords that you enter literally as shown.
Italic Italic text represents arguments that you replace with actual values.
[ ] Square brackets enclose syntax choices (keywords or arguments) that are optional.
{ x | y | ... }
Braces enclose a set of required syntax choices separated by vertical bars, from which
you select one.
[ x | y | ... ]
Square brackets enclose a set of optional syntax choices separated by vertical bars, from
which you select one or none.
{ x | y | ... } *
Asterisk marked braces enclose a set of required syntax choices separated by vertical
bars, from which you select a minimum of one.
[ x | y | ... ] *
Asterisk marked square brackets enclose optional syntax choices separated by vertical
bars, from which you select one choice, multiple choices, or none.
&<1-n>
The argument or keyword and argument combination before the ampersand (&) sign can
be entered 1 to n times.
# A line that starts with a pound (#) sign is comments.
GUI conventions
Convention Descri
p
tion
Boldface
Window names, button names, field names, and menu items are in Boldface. For
example, the New User window opens; click OK.
> Multi-level menus are separated by angle brackets. For example, File > Create > Folder.
Symbols
Convention Descri
p
tion
WARNING
An alert that calls attention to important information that if not understood or followed can
result in personal injury.
CAUTION
An alert that calls attention to important information that if not understood or followed can
result in data loss, data corruption, or damage to hardware or software.
IMPORTANT
An alert that calls attention to essential information.
NOTE
An alert that contains additional or supplementary information.
TIP
An alert that provides helpful information.
Network topology icons
Represents a generic network device, such as a router, switch, or firewall.
Represents a routing-capable device, such as a router or Layer 3 switch.
Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports
Layer 2 forwarding and other Layer 2 features.
Represents an access controller, a unified wired-WLAN module, or the access controller
engine on a unified wired-WLAN switch.
Represents an access point.
Wireless terminator unit.
Wireless terminator.
Represents a mesh access point.
Represents omnidirectional signals.
Represents directional signals.
Represents a security product, such as a firewall, UTM, multiservice security gateway, or
load balancing device.
T
T
T
T
Represents a security module, such as a firewall, load balancing, NetStream, SSL VPN,
IPS, or ACG module.
Examples provided in this document
Examples in this document might use devices that differ from your device in hardware model,
configuration, or software version. It is normal that the port numbers, sample output, screenshots, and
other information in the examples differ from what you have on your device.
Obtaining documentation
To access the most up-to-date H3C product documentation, go to the H3C website
at http://www.h3c.com.hk
.
To obtain information about installation, configuration, and maintenance, click
http://www.h3c.com.hk/Technical_Documents
To obtain software version information such as release notes, click
http://www.h3c.com.hk/Software_Download
Technical support
http://www.h3c.com.hk
Documentation feedback
You can email your comments about product documentation to info@h3c.com.
We appreciate your comments.
i
Contents
Product overview ·························································································································································· 1
Chassis views ···································································································································································· 1
SR8802 chassis views ············································································································································· 2
SR8805 chassis views ············································································································································· 4
SR8808 chassis views ············································································································································· 6
SR8812 chassis views ············································································································································· 8
Power supply system ························································································································································· 9
AC power modules ··············································································································································· 10
DC power modules ··············································································································································· 11
Cooling system ······························································································································································· 13
Fan trays ································································································································································· 13
Airflow design for the SR8802 and SR8805 and SR8812 ·············································································· 15
Airflow design for the SR8808 ···························································································································· 15
Preparing for installation ··········································································································································· 17
Safety recommendations ··············································································································································· 17
General safety recommendations ························································································································ 17
Electricity safety ····················································································································································· 17
ESD prevention ······················································································································································ 17
Router moving ························································································································································ 18
Laser safety ····························································································································································· 18
Examining the installation site ······································································································································ 19
Weight support ······················································································································································ 19
Temperature ··························································································································································· 19
Humidity ································································································································································· 19
Cleanness ······························································································································································· 20
EMI requirements ··················································································································································· 20
Grounding ······························································································································································ 20
Power supply ·························································································································································· 21
Space ······································································································································································ 21
Rack-mounting ································································································································································ 21
Installation tools ······························································································································································ 23
Installing the router ····················································································································································· 25
Inspecting the router ······················································································································································ 25
Installing the router in a rack ········································································································································ 25
Installation preparation ········································································································································· 26
Installing slide rails and cage nuts to the rack ··································································································· 26
Installing the cable management brackets ·········································································································· 28
Installing the mounting brackets ··························································································································· 30
Installing an impedance carrier (optional) ·········································································································· 31
Installing the router to a rack ······························································································································· 31
Verifying the installation ······································································································································· 32
Grounding the router ····················································································································································· 32
Installing the power system ··········································································································································· 33
Installation preparation ········································································································································· 34
Installing a DC power module ····························································································································· 34
Installing an AC power module ··························································································································· 35
Installing a card ······························································································································································ 36
Installation preparation ········································································································································· 36
ii
Installation procedure ··········································································································································· 37
Installing a subcard ························································································································································ 37
Installation preparation ········································································································································· 38
Installation procedure ··········································································································································· 38
Connecting power cords ··············································································································································· 39
Prerequisites ··························································································································································· 39
Connecting an AC power cord ··························································································································· 39
Connecting a DC power cord ······························································································································ 42
Verifying the installation ················································································································································ 43
Connecting the router to the network ······················································································································· 44
Logging in to the router ················································································································································· 44
Connecting the console cable ······························································································································ 44
Setting up a configuration environment ·············································································································· 45
Powering on the router ·················································································································································· 48
Verification before power-on ······························································································································· 48
Powering on the router ········································································································································· 48
Verification after power-on ··································································································································· 49
Connecting the router to the network ··························································································································· 50
Connecting the router to the network through an AUX cable ··········································································· 50
Connecting the router to the network through an Ethernet twisted pair cable ··············································· 50
Connecting the router to the network through an optical fiber ········································································ 50
Cable routing recommendations ·································································································································· 53
Hardware management ············································································································································· 54
Displaying the electrical label data for your router ···································································································· 54
Displaying the card information ··································································································································· 54
Rebooting your router ···················································································································································· 55
Displaying the power supply system ···························································································································· 56
Configuring temperature alarm thresholds for a card································································································ 57
Configuring temperature alarm thresholds for a card ······················································································· 57
Displaying the temperature information ·············································································································· 57
Configuring in-service hardware failure diagnosis ···································································································· 58
Displaying the operating state of fans ························································································································· 58
Displaying the alarming information of a card ··········································································································· 58
Verifying and diagnosing transceiver modules ·········································································································· 59
Introduction to transceiver modules ····················································································································· 59
Verifying transceiver modules ······························································································································ 59
Diagnosing transceiver modules ·························································································································· 61
Troubleshooting ·························································································································································· 64
Configuration terminal problems ·································································································································· 64
No terminal display ·············································································································································· 64
Garbled terminal display ······································································································································ 64
Power supply system failure ·········································································································································· 65
Fan failure ······································································································································································· 66
MPU failure ····································································································································································· 66
LPU failure ······································································································································································· 67
Interface failure ······························································································································································· 67
Technical support ··························································································································································· 68
Replacement procedures ··········································································································································· 69
Replacing a power supply system ································································································································ 69
Preparing for the replacement ····························································································································· 69
Replacing a DC power module ··························································································································· 69
Replacing an AC power module ························································································································· 70
iii
Cleaning the air filter of a power module ··················································································································· 72
Replacing a card ···························································································································································· 72
Preparing for the replacement ····························································································································· 73
Replacement procedure ········································································································································ 73
Replacing a subcard ······················································································································································ 74
Replacement procedure ········································································································································ 74
Replacing a fan tray ······················································································································································ 75
Replacing a fan tray for an SR8802/SR8805/SR8812 ·················································································· 75
Replacing a fan tray for an SR8808 ··················································································································· 76
Replacing a chassis air filter ········································································································································· 77
Replacing chassis air filters for an SR8808 ······································································································· 77
Replacing the air filter for an SR8802/SR8805/SR8812 ··············································································· 78
Replacing a CF card ······················································································································································ 78
Replacing a transceiver module ··································································································································· 80
Appendix A Technical specifications ························································································································ 82
Environment requirements ············································································································································· 82
Chassis specifications ···················································································································································· 82
Card specifications ························································································································································ 83
MPU specifications ················································································································································ 85
SPC card specifications ········································································································································ 86
SPE base card specifications ······························································································································· 87
MPE base card specifications ······························································································································ 87
Subcard specifications ·········································································································································· 88
OAA module specifications ································································································································· 91
Transceiver module and cable specifications ····································································································· 92
Fan tray specifications ··················································································································································· 94
Power system specifications ·········································································································································· 94
Appendix B LEDs ························································································································································ 99
Power module LEDs ························································································································································ 99
Fan LEDs ·········································································································································································· 99
MPU LEDs ······································································································································································ 100
CF card status LED ··············································································································································· 100
Network management port LEDs ······················································································································· 101
LPU status LEDs ····················································································································································· 101
MPU status LEDs ·················································································································································· 101
SPC card LEDs ······························································································································································ 102
LINK/ACT LED ····················································································································································· 102
Combo interface LED ·········································································································································· 102
LINK and ACT LEDs ············································································································································· 103
SPE/MPE card LED ······················································································································································ 104
Subcard LEDs ································································································································································ 104
Appendix C Lightning protection ··························································································································· 105
Connecting the AC power supply to a power strip with lightning protection ······················································· 105
Installing a lightning protector for a network port ···································································································· 106
Appendix D Engineering labels ····························································································································· 108
Labels for cables··························································································································································· 108
Labels for signal cables ······································································································································ 108
Labels for power cords ······································································································································· 108
Generic labels······················································································································································ 109
Labels for devices ························································································································································· 110
Filling in labels ····························································································································································· 110
Affixing labels ······························································································································································· 110
iv
Affixing a label to a signal cable ······················································································································ 110
Affixing a label to a power cord ······················································································································· 111
Affixing a generic label ······································································································································ 112
Affixing a label to a device ································································································································ 113
Guidelines ····································································································································································· 113
Examples ······································································································································································· 113
Engineering labels for network cables ·············································································································· 113
Engineering labels for optical fibers·················································································································· 115
Engineering labels for DC power cords ··········································································································· 117
Engineering labels for AC power cords ··········································································································· 118
Engineering labels for devices ··························································································································· 119
Appendix E Cable management ···························································································································· 120
Cable management guidelines ··································································································································· 120
Cable management examples ···································································································································· 122
Index ········································································································································································ 124
1
Product overview
The H3C SR8800 routers include the models in Table 1.
Table 1 SR8800 router chassis
Chassis Power in
p
ut
Card slot orientation
MPU slots
LPU slots
SR8802 AC/DC Horizontal 2/1 2/3
SR8805 AC/DC Horizontal 2 5
SR8808 AC/DC Vertical 2 8
SR8812 AC/DC Horizontal 2 12
NOTE:
A main processing unit (MPU) is the supervisor engine of a router, and a line processing unit (LPU)
receives and forwards traffic and provides network services.
The LPU slots can hold SPE cards, MPE cards, SPC cards, and OAA cards. For the card specifications,
see "Appendix A Technical specifications."
Chassis views
The diagrams in this guide are for illustration only, and AC-powered chassis are used for example.
2
SR8802 chassis views
Figure 1 SR8802 front view
(1) ESD-preventive wrist strap port (2) MPU slots (slots 0 and 1)
(3) LPU slots (slots 2 and 3) (4) Power module slots
NOTE:
Slot 0 is for an MPU, while Slot 1 can be used for an MPU or LPU.
You can install one or two power modules, but intermixin
g
of AC and DC power modules is not allowed.
In this figure, two AC power modules are installed.
2
3
4
4
3
Figure 2 SR8802 rear view
(1) Rear cover handle (2) Groundin
g
screw
(3) Fan tray
3
2
4
SR8805 chassis views
Figure 3 SR8805 front view
(1) ESD-preventive wrist strap port (2) MPU
slots (slots 0 and 1) (3)
LPU slots (slots 2 to 6)
(4) Power module
slots (5)
PoE
power
entry module
(reserved, currently not available)
NOTE:
You can install one or two power modules, but intermixin
of AC and DC power modules is not allowed.
In this figure, two AC power modules are installed.
2
3
4 4
5
5
Figure 4 SR8805 rear view
(1) Rear cover handle (2) Grounding screw (3) Fan tray
1
2
3
6
SR8808 chassis views
Figure 5 SR8808 front view
(1) Fan tray (2) MPU slots (slots 4 and 5) (3) LPU slots (slots 0 to 3, 6 to 9)
(4) Cable mana
g
ement bracket (5) Power module
slots
(6) PoE power entry module (reserved, currently not available)
(7) ESD-preventive wrist strap port
NOTE:
You can install one or two power modules, but intermixin
of AC and DC power modules is not allowed.
In this figure, two AC power modules are installed.
3
3
2
5
4
4
5
4
4
7
1
6
3
3
2
5
4
4
5
4
4
7
1
6
7
Figure 6 SR8808 rear view
(1) Air filter (2) Grounding screw (3) Rear cover handles
8
SR8812 chassis views
Figure 7 SR8812 front view
(1) ESD-preventive strap port (2) LPU slots (slots 0 to 5, 8 to 13) (3) MPU slots (slots 6 and 7)
(4) Power module
slots (5) PoE
power
entry module (reserved, currently not available)
NOTE:
You can install one or two power modules, but intermixin
of AC and DC power modules is not allowed.
In this figure, two AC power modules are installed.
3
2
2
4 4
5
9
Figure 8 SR8812 rear view
(1) Rear cover handle (2) Groundin
g
screw
(3) Fan tray
Power supply system
The SR8800 routers support both AC and DC power modules, but the power modules installed on an
SR8800 router must be the same model. H3C recommends that you install two power modules for
redundancy.
Table 2 lists the po
wer modules available for the SR8800 routers. All these power modules are hot
swappable. For the specifications of AC power modules, see Table 3. F
or the specifications of DC power
modules, see Table 4.
Table 2 Power module compatibility matrix
Powe
r module SR8802 SR8805
SR8808
SR8812
NEPS800-A Yes No No No
NEPS1300-D Yes No No No
NEPS2000-D No Yes Yes Yes
NEPS1800-A No Yes Yes Yes
NEPS3500-D No No Yes Yes
10
NOTE:
Use the NEPS2000-D for the SR8808 and SR8812 routers only when the number of cards is small.
AC power modules
Table 3 AC power module specifications
Item NEPS800-A NEPS1800-A
Rated input
voltage range
100 VAC to 240 VAC @ 50 Hz or 60 Hz 100 VAC to 240 VAC @ 50 Hz or 60 Hz
Max input
voltage range
90 VAC to 264 VAC @ 50 Hz or 60 Hz 90 VAC to 264 VAC @ 50 Hz or 60 Hz
Max input
current
12 A @ 100 V
16 A @ 110 V
12 A @ 22 0 V
Max output
power
800 W
1200 W (100 VAC to 120 VAC)
1800 W (200 VAC to 240 VAC)
Figure 9 NEPS800-A power module
(1) Power input LED (2) Power output LED (3) Power fault LED
11
Figure 10 NEPS3500-A power frame
(1) Power input LED
(2) Power output LED
(3) Power fault LED
(4) Power modules
You can install one or two NEPS1800-A AC power modules into the NEPS3500-A power frame. If two
NEPS1800-A power modules are installed, the maximum output power is 3500 W.
Table 4 AC power module LED description
LED Color Status Descri
p
tion
Input Green
Steady on The input voltage is in the normal range.
Off
The power module or power supply is absent or has an input voltage
error.
Output Green
Steady on
The power module or power supply is correctly outputting power.
Off
The power module or power supply is absent or has an output voltage
error.
Fault Red
Steady on
The power module or power supply is experiencing an overvoltage,
overcurrent, or over-temperature condition.
Off The power module or power supply is operating correctly or absent.
DC power modules
Table 5 DC power module specifications
Item NEPS1300-D
NEPS2000-D
NEPS3500-D
Rated input voltage range
–48 VDC to –60 VDC –48 VDC to –60 VDC –48 VDC to –60 VDC
Max input voltage range
–36 VDC to –72 VDC –36 VDC to –75 VDC –36 VDC to –75 VDC
Max input current 46 A @ –48 V 45 A @ –48 V 80 A @ –48 V
/