User manual

Aurine AH8-WA802 is a public entry station converter, it is an auxiliary device for connecting the Public Entry Station into the AH8000 system, assisting in realizing video intercom, surveillance and alarm. It has a memory capacity of 50000 cards/500 passwords. The system capacity is 2 Secondary Entry Stations / 1 Primary Entry Station. It supports Time Settings, Volume Settings and Output Video Settings. The device has a TCP/IP port and can be connected to a LAN.

Aurine AH8-WA802 is a public entry station converter, it is an auxiliary device for connecting the Public Entry Station into the AH8000 system, assisting in realizing video intercom, surveillance and alarm. It has a memory capacity of 50000 cards/500 passwords. The system capacity is 2 Secondary Entry Stations / 1 Primary Entry Station. It supports Time Settings, Volume Settings and Output Video Settings. The device has a TCP/IP port and can be connected to a LAN.

Public Entry Station Converter
AH8-WA802
USER MANUAL
1. OVERVIEW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3. APPEARANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
4. DIAGRAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.1 System Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4.2 Public Entry Station Converter & Public Entry Station . . . . . . . 4
4.3 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5. SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5.1 Initial Settings on Public Entry Station . . . . . . . . . . . . . . . . . . . . 4
5.2 Settings on Secondary Entry Station . . . . . . . . . . . . . . . . . . . . . . 7
5.2.1 Enter the Programming Mode . . . . . . . . . . . . . . . . . . . . . . . . 7
5.2.2 Card Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.2.3 Password Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.2.4 Resident Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2.5 Door & Lock Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2.6 System Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2.6.1 Device No. settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2.6.2 Network settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2.6.3 Security settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.2.6.3.1 Set a way of PIN access. . . . . . . . . . . . . . . . . . . . 12
5.2.6.3.2 Set alarm parameters . . . . . . . . . . . . . . . . . . . . . . 12
5.2.6.3.3 Set snapshot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2.6.3.4 Set saving mode . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2.7 System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.2.8 Restore Factory Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.3 Settings on Primary Entry Station. . . . . . . . . . . . . . . . . . . . . . . . 14
5.3.1 Enter the Programming Mode . . . . . . . . . . . . . . . . . . . . . . . 14
5.3.2 Card Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.3.3 Password Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CONTENTS
№ 201304-A0
5.3.4 Door & Lock Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.3.5 System Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.3.6 System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.4 Settings on Public Entry Station Converter. . . . . . . . . . . . . . . . 17
5.4.1 Time Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.4.2 Volume Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.4.3 Output Video Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.4.4 Simulative Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.4.5 Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.4.6 Other Indications on Digital Indicator. . . . . . . . . . . . . . . . 18
6. DIMENSIONS & INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . 19
7. APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1
TK2 TK1
LH
AGAU V+ V - +-
J_LAN
T K1 _ V TK2_V
VD1
VG1
VD2
VG2
DISPLAY
RST FUN
<
<
OK
12 3 4
5
6
7
8
9
1011
TCP/IP DC18V
LH
AGAU
121314
V+ V-
Public Entry Station Converter AH8-WA802, installed at public entry, is an
auxiliary device for connecting Public Entry Station into AH8000 system,
assisting in realizing video intercom, surveillance and alarm.
1. OVERVIEW
2.TECHNICAL SPECIFICATIONS
Input Voltage DC18V Standby Current 200mA
Ambient Temperature -10+55Working Current 300mA
Memory Capacity
System Capacity 2 Secondary Entry Stations/1 Primary Entry Station
50000 cards/500 passwords
3. APPEARANCE
Fig. 1
2
NO. TAG PORT REFERENCE
1 J_LAN TCP/IP to LAN
V+ to power port (+) on Secondary Entry Station 2
V- to power port (-) on Secondary Entry Station 2
AU to Port A+ on Secondary Entry Station 2
AG to Port A- on Secondary Entry Station 2
H CAN communication port (H)
L CAN communication port (L)
V+ to power port (+) on Secondary Entry Station 1
V- to power port (-) on Secondary Entry Station 1
AU to Port A+ on Secondary Entry Station 1
AG to Port A- on Secondary Entry Station 1
H CAN communication port (H)
L CAN communication port (L)
+ power(+)
- power(-)
5 / / power LEDilluminates when the device is
powered on
6 D_100M / communication LEDflashes when the
communication is in progress
7 D_LINK / network LEDilluminates when network
connection works)
8 OK / OK Button (press it to confirm the settings)
/ up/increase
/ down/decrease
10 FUN / Function Button
11 RST / Reset Button (press it to restart the device)
12 DISPLAY / Digital Indicator
VD2 video port (+) on Secondary Entry Station 2
VG2 video port (-) on Secondary Entry Station 2
VD1 video port (+) on Secondary Entry Station 1
VG1 video port (-) on Secondary Entry Station 1
2 TK2
3 TK1
14 TK1_V
13
4 DC18V
9
TK2_V
Tk1 Tk2
v+ v- LH
AGAU V+ V - +-
J_LAN
TK1_V TK2_V
VD1
VG1
VD2
VG2
DISPLAY
REST FUN
<
<
OK
TCP/IP DC18 V
LH
AGAU
摘 机
报 警
UTP5
RVV6*0.5
RVV6*0.5
SYV75-3
UTP5 UTP5 UTP5
UTP5
RVV2*0.5
SYV75-3
Tk1 Tk2
v+ v- LH
AGAU V+ V - +-
J_LAN
TK1_V TK2_V
VD1
VG1
VD2
VG2
DISPLAY
REST FUN
<
<
OK
TCP/IP DC18 V
LH
AGAU
RVV6*0.5
SYV75-3
UTP5
3
4. DIAGRAM
4.1 System Diagram
Power
Supply
mains power
LAN
Indoor Terminal1 Admin Unit
Center Server
Public Entry Station Converter 1
Secondary Entry Station 1
Primary Entry Station
Indoor Terminal N
Public Entry Station Converter N
Power
Supply
mains power
Secondary Entry Station 2
Fig. 2
4
4.3 Cable
DESCRIPTION SPECIFICATION LENGTH
cable from Public Entry Station Converter to
Exchanger 1*UPT5 80m
RVV6*0.5 30m
SYV75-3 30m
cable from Public Entry Station Converter to
Public Entry Station
4.2 Public Entry Station Converter & Public Entry Station
Fig.3
5. SETTINGS
Select A Language
中文简体
中文繁體
AH8000
Select A System
AH1000
AH2000
1
You should carry out the below settings after wiring the whole system and
electrifying the device.
*The initial settings and parameters modifications referred in Section 5.1-
5.3 should be done on Public Entry Station.
English
2
3
18V+18V-
VD VG
A+
AG H L OUT+ OUT- L+
L-
12V+12V-
TK1_V
V+ V- HL
Public Entry Station 1
SYV75-3
VD
RVV6*0.5
A-
AU
VG
TK1
Public Entry Station Converter
Wire the system and then electrify the devices
Press or to select a language
and then press .
Press or to select AH8000
and then press .
5.1 Initial Settings on Public Entry Station
Note: when only one General Secondary Entry Station is
connected into Public Entry Station Converter, a 120Ω resistor
is required to be connected in parallel to Terminal H & L of Port
TK1.
5
Location
Prim.Entry
Sec.Entry
Device No.
ID: 1
Stairway No: 0000
Enable riser: Y
Device No.
ID: 1
Stairway No: 0101
Enter the 4-digit Stairway No.
Enable riser: Y
Device No.
ID: 1
Stairway No: 0101
Enable riser: Y
Press or to activate
/deactivate riser No. and then press .
4
5
6
7
When "Sec. Entry"is selected
Press or to locate a location
where the device is installed and then
press to set the device as Secondary
/ Primary Entry Station.
Enter the Secondary Entry Station
ID (18) .
Notes:
1.When two Secondary Entry Stations are connected into the Public Entry
Station Converter, their ID should be two continuous numbers.
2. The ID number of Secondary Entry Station connected to Port TK1 should
be odd, and the one to port TK2 should be even.
3. Only the Secondary Entry Station connected to Port TK1 is available to be
monitored via Indoor Terminal.
Device No.
Device No:01
5'
Enable riser:Y
When "Prim. Entry"is selected
Enter the Device No. of Primary
Entry Station(01-40) and then press .
6
Device No.
Device No: 1
Enable riser:Y
6'
Press or to activate
/deactivate riser No. and then press .
Enter the IP address of the Public
Entry Station Converter and then
press .
Network
000.000.000.000
Device IP
Network
Subnet Mask:
000.000.000.000
Network
Gateway:
000.000.000.000
Network
Admin Unit:
000.000.000.000
Network
Center Server:
000.000.000.000
8
9
10
11
12
Enter the Subnet Mask and then
press .
Enter the IP address of Gateway and
then press .
Enter the IP address of Admin Unit and
then press .
Enter the IP address of Center Server
and then press .
7
RTSP:
000.000.000.000
13
Notes:
1. During step 8-12, you can use or to move the cursor.
2. The above parameters should be set correctly to guarantee the normal work
of Public Entry Station connected.
3. The Public Entry Station Converter can only support one Primary Entry
Station.
Card
Password
Door&Lock
Settings
Installer PWD
15
16
Card
Add A Card
Del A Card
Empty
17
5.2.1 Enter the Programming Mode
5.2.2 Card Settings
After “Card” is selected in Step 16
5.2 Settings on Secondary Entry Station
If “Sec. Entry” is selected in step ,
parameters as below after finishing the Initial Settings,.
you may program the other
Press or to locate an item
and then press .
Press or to locate an item
and then press .
Press five times when the Secondary Entry Station is standby.
14
Enter the 8-digit installer password
(default: 38131800) and then press .
4
Enter the IP address of RTSP Server
and then press to finish the settings.
Network
8
Note: card(s) added after apartment number “0000" is selected will not be
attached to any apartment. You may attach multiple cards to an apartment.
Del A Card
Apt. No.: 0000
Card No.:
123456
Del all Cards
=Yes *=No
19
Password
Add Unlock PWD
Del Unlock PWD
Empty
20
21
After “Del A Card” is selected in Step 17
Delete all cards attached to an
apartment:
Press or to select an
apartment; or press to delete the
number and enter a new one. Then
press .
Delete a card:
Enter a 6-digit card number; or
present a card to card reader.
After “Empty” is selected in Step 17
Delete all cards:
Press .
*To cancel the operation, press
instead.
5.2.3 Password Settings
After “Password” is selected in Step 16
Press or to select an item
and then press .
Add A Card
Apt. No.: 0000
Card No.
123456
a.
apartment; or press to delete the
apartment number and enter a new one.
b. enter a 6-digit card number; or
present a card to card reader.
press or to select an
Add card:
After “Add A Card” is selected in Step 17
18
9
Add Unlock PWD
Apt. No.: 0000
Password
*****_
After “Add Unlock PWD” is selected in Step 21
a.
apartment; or press to delete the
number and enter a new one .
b. Enter a 6-digit unlock password.
Press or to select an
Add unlock password:
22
Note: Unlock p
attached to any apartment. An apartment can only have one unlock password
(most recently set).
assword(s) added after apartment number “0000will not be
*=No =Yes
Del Unlock PWD
Apt. No. : 0101
Del all Unlock
Pawwrods
________
Installer PWD
New
23
24
25
After “Del Unlock PWD” is selected in Step 21
Enter an apartment number and then
press .
Delete the unlock password attached
to an apartment:
Delete all unlock passwords:
Press .
*To cancel the operation, press
instead.
After “Empty” is selected in Step 21
Change installer password:
Enter a new 8-digit installer
password and then press .
After “Installer PWD” is selected in Step 21
Enter a 2-digit number as the starting
room No. and then press .
Starting Room No.
01
26
5.2.4 Resident Settings
16
After “Resident” is selected in Step
Resident
10
Enter the number of total storeys in
the riser and then press .
Enter the number of total apartments
per floor and then press .
Total Storeys
08
Apts/floor: 04
Resident
27
28
Resident
Apt. No.: 0101
Resident
Resident
Tom_____________
5.2.5 Door & Lock Settings
Lock Settings
Door&Lock
Door Settings
Notes
1. Memory capacity: 250 residents*16 characters
2. Resident Settings function are not available on Primary Entry Station.
3. For the arrangement of letters, refer to Appendix.
30
29
30
Lock Type
0S
3S
6S
Fail-secure
Fail-safe
Unlock Time
31
32
Edit resident’s name:
apartment and then enter the resident’s
name. Then press .
Press or to select an
Set unlock time
Press or to locate an option
(0s/3s/6s) and then press .
Press or to locate a lock type
and then press .
Set lock type:
After “Door&Lock” is selected in Step 16
Press or to select an item and
then press .
After “Lock Settings” is selected in Step
11
Activate door open alarm
Press or to locate Yes and then
press .
*To cancel the operation, select No
instead.
Yes
No
Door Open Alarm
33
30
After “Door Settings” is selected in Step
*1. Alarm Sound deactivated: the Secondary Entry Station will not make an
alarm sound when the Unclosed Door alarm is triggered.
2. Alert Admin deactivated: the Secondary Entry Station will not alert admin
when the Unclosed Door alarm is triggered.
Activate alarm sound
Press or to locate Yes and
then press .
*To cancel the operation, select No
instead.
Yes
No
Alarm Sound
Alert Admin
Press or to locate Yes/No to
enable/disable Alert Admin function.
Then press .
Yes
No
Alert Admin
34
35
5.2.6.1 Device No. settings
5.2.6.2 Network settings
After “Device No.” is selected in Step , repeat steps to set
Secondary Entry Station ID, stairway No. and activate/deactivate riser
number.
5
36
813
5.2.6 System Settings
Parameters
Device No.
Network
Security
36
Press or to locate an item and
then press .
After “Parameters” is selected in Step 16
After “Network” is selected in Step , repeat steps to set IP
address of the device, subnet mask, Admin Unit and Center Server.
36
7
12
5.2.6.3 Security settings
37 PIN Access
Security
Snapshot
Alarm Settings
After “Security” is selected in Step 36
Press or to locate an item
and then press .
5.2.6.3.1 Set a way of PIN access
38
Unclosed Door
Alarm
Activate
Deactivate
Force Open Alarm
Activate
Deactivate
39
39
* Unclosed door alarm: alarm triggered when the door is unclosed for over 2
minutes after it is opened legally.
Force open alarm: alarm triggered when the door is opened by force.
PIN Access
PIN+Apt. No.
PIN
* Two ways of PIN access:
a. PIN: unlock the gate with the unlock password set on Secondary Entry
Station(see PAGE 8)
b. PIN+Apt. No.: unlock the gate with the unlock password set on Indoor
Terminal and the corresponding apartment number
When PIN+Apt. No. is selected in Step , the unlock password can only be
set on Indoor Terminal.
After “PIN Access” is selected in Step 37
Press or to locate a way of
PIN access and then press .
38
5.2.6.3.2 Set alarm parameters
After “Alarm Settings” is selected in Step 37
Press or to locate Activate
and then press .
*To cancel the operation, select
Deactivate instead.
Activate unclosed door alarm
Press or to locate Activate
and then press .
*To cancel the operation, select
Deactivate instead.
Activate force open alarm
13
41
5.2.6.3.3 Set snapshot
After “Snapshot” is selected in Step 37
Visitor calls
Deactivate
Activate
Press or to locate Activate
and then press .
*To cancel the operation, select
Deactivate instead.
Activate snapshot when visitor calls
42
Notes:
1. visitor calls: enables built-in camera to take pictures when visitor calls and
then uploads them to Admin Unit
2. WrongPIN entered: enables built-in camera to take pictures when a wrong
PIN is entered and then uploads them to Admin Unit
3.Duress occurs: enables built-in camera to take pictures when duress
occurs(i.e., a duress PIN is entered) and then uploads them to Admin Unit.
4. Duress PIN: unlocl PIN plus 1. If the unlock PIN ends with a 9, such that
would result in carrying a 1 to the ten’s place, subtract 10 after adding 1 to
obtain the duress PIN(e.g. 56789 56789+1=56790 56790-10=56780
=duress PIN )
43
44
* Saving mode activated: the keypad backlight will be extinguished
automatically when no operation detected for over 2 minutes.
WrongPIN entered
Deactivate
Activate
Duress occurs
Deactivate
Activate
Press or to locate Activate
and then press .
*To cancel the operation, select
Deactivate instead.
Activate snapshot when wrong PIN
entered
Press or to locate Activate
and then press .
*To cancel the operation, select
Deactivate instead.
Activate snapshot when duress occurs
5.2.6.3.4 Set saving mode
Saving Mode
ON
OFF
After “Saving Mode” is selected in Step 37
Press or to locate ON and
then press .
*To cancel the operation, select OFF
instead.
Activate saving mode
14
5.2.7 System Information
16
45 Press or to view system
information.
AH8000 Secondary
Entry Station
01011#
System Info
After “System Info” is selected in Step
46
5.2.8 Restore Factory Settings
47
Follow step and .
14
49
50
Device: V1.0
N.C.: V1.0
Free C. M.: 000500
System Info
Press or to view system
information.
Restore factory
settings ?
=YES =No
Press to restore factory settings;
or press to cancel the operation.
*After restoring the factory settings,
the device will restart automatically.
16
After “Restore” is selected in Step
5.3 Settings on Primary Entry Station
5.3.1 Enter the Programming Mode
If “Prim. Entry” is selected in step ,
parameters as below after finishing the Initial Settings,.
you may program the other
4
48 15
Card
Password
Door&Lock
Settings
Card
Add A Card
Del A Card
Empty
5.3.2 Card Settings
After “Card” is selected in Step 49
Press or to locate an item
and then press .
Press or to locate an item
and then press .
15
12345_
51
Add A Card
Card No. Enter a 6-digit card number; or
present a card to card reader.
Add card:
After “Add A Card” is selected in Step 50
*Access cards added on Primary Entry Station are not attached to any
apartment.
Del A Card
Card No.:
123456
52
53
a. press to delete the group number
and enter a new one.
b. enter 6-digit unlock password.
Add Unlock PWD
No.: 0001
Password
*****_
54
55
Del all Cards
=Yes *=No
Password
Add Unlock PWD
Del Unlock PWD
Empty
After “Del A Card” is selected in Step 50
After “Empty” is selected in Step 50
Delete all cards:
Press .
*To cancel the operation, press
instead.
5.3.3 Password Settings
After “Password” is selected in Step 49
Press or to select an item and
then press .
After “Add Unlock PWD” is selected in Step 54
Add unlock password:
Enter a 6-digit card number; or
present a card to card reader.
Delete a card:
16
Notes
1. 10000 groups of unlock passwords can be set, ranging from 0000 to 9999.
2.You may attach multiple unlock passwords to a group. E.g., set the unlock
password owned by residents in one building under a same group.
56
58
*=No =Yes
Del Unlock PWD
No. : 0101
Del all Unlock
Pawwrods
________
Installer PWD
New
57
After “Del Unlock PWD” is selected in Step 54
Enter a group number and then
press .
Delete the unlock password in a group:
Delete all unlock passwords:
Press .
*To cancel the operation, press
instead.
After “Empty” is selected in Step 54
Change installer password:
Enter a new 8-digit installer
password and then press .
After “Installer PWD” is selected in Step 54
5.3.4 Door & Lock Settings
See Section 5.2.5.
5.3.5 System Settings
See Section 5.2.6.
5.3.6 System Information
AH8000 Primary
Entry Station01#
59
System Info
16
After “System Info” is selected in Step
Press or to view system
information.
17
5.4 Settings on Public Entry Station Converter
You should carry out the below settings on Public Entry Station Converter.
* The relative settings information will be displayed on the Digital
Indicator.
5.4.1 Time Settings
1. Press and hold FUN Button for above 3 seconds, then release the button
to access time settings;
2. Press FUN Button to select a digit;
3. Press or to increase/decrease the value;
4. Press OK Button to complete the settings.
*a. Display Mode: HH(hour)MM(minute)
b. the blinking digit indicates that the digit is on the setting mode.
5.4.2 Volume Settings
set the output & input volume
1. press FUN Button several times until F is displayed;
2. Press or to select 1 or 2;
(1: input volume settings; 2:output volume settings)
3. press OK Button to access the settings;
4.Press or to set the volume;
5. Press OK Button to complete the settings.
5.4.3 Output Video Settings
1. press FUN Button several times until q is displayed;
2. press OK Button to access the settings;
3.Press or to select a level of video quality;
(0:low; 1:medium; 2:high)
4. Press OK Button to complete the settings.
5.4.4 Simulative Commissioning
1. press FUN Button several times until C is displayed;
2. Press or to select1, 2 or 3;
(1:simulate calling admin; 2/3: N/A)
3. Press OK Button to complete the simulation.
5.4.5 Version
1. press FUN Button several times until U is displayed to view the version.
"U1_0": version 1.0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Aurine AH8-WA802 User manual

Type
User manual

Aurine AH8-WA802 is a public entry station converter, it is an auxiliary device for connecting the Public Entry Station into the AH8000 system, assisting in realizing video intercom, surveillance and alarm. It has a memory capacity of 50000 cards/500 passwords. The system capacity is 2 Secondary Entry Stations / 1 Primary Entry Station. It supports Time Settings, Volume Settings and Output Video Settings. The device has a TCP/IP port and can be connected to a LAN.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI