Testing the 9212i Keypad
1. Connectthepositive(+)leadofyourpowersupply
totheterminalstrip(TS1)+Vinput.
2. Connectthenegative(-)leadofyourpower
supplytotheterminalstrip(TS1)-Vinput.
3. Turnonyourpowersupply.
4. Press7890#123456*.Ifall12keypresseshave
beenverified,thekeypadwillenterselftestmode.
TheyellowLEDwillflashthreetimes,thenlight
orsoundcontinuouslyfor3seconds.Ifthese
responsesdonothappen,trythetestmodeagain
andthencalltechsupport.Note:selftestmode
canbeusedwhentroubleshootingakeypadinthe
field.Ifyoudonotgetthecontinuouslightthenthe
memoryhasbeencorruptandshouldbe
re-programmedwiththe46command
(seeoption#18).
5. Enterthemastercodeof1234*.Therelaywill
energize.Refertoprogrammingsectiontoprogram
yourkeypad.
Note:The9212ikeypadmaybeprogrammedinyourshop
orattheinstallationsite.Programmedinformationisstored
innon-volatilememorysoitwillnotbelostifpoweris
removed.
RCI Keypad Defaults
RCIkeypadsaredesignedforeasyinstallationina
minimumamountoftime.Thefollowingdefaultshave
beenfactoryprogrammed:
MasterCode(user1) 1234*
MainRelaywillenergizefor 5 seconds
AuxiliaryOutputswillenergizefor 5 seconds
Panicwillenergize Output 4
KeypadActiveOutput Off
RemoteTriggeringInputwillenergize Main Relay
KeypressFeedback On
LEDonwhenpoweredup RED
LEDonwhenrelayisactivated GREEN
Ifdefaultsmustbechangedoradditionalfunctionsare
desired,pleaserefertotheProgrammingOptionschart
afteryouarefamiliarwiththeProgrammingsection.
Programming
1. Enterprogrammingmode YellowLED
Press 99#(mastercode)* Flashesslowly
2. Tochangemastercode
‡
Press 1#(newmastercode)* Flashesfast
Repeat(newmastercode)* Flashesslowly
Ifmainrelaytimemustbechanged,substituteoption2
fromProgrammingOptionschartforstepabove.
3. Toadd/changesecondcode
Press 2#(newusercode)* Flashesfast
Repeat (newusercode)* Flashesslowly
4. Toadd/changethirdcode
Press 3#(newusercode)* Flashesfast
Repeat (newusercode)* Flashesslowly
5. Upto120codesmaybeaddedinthisfashion
6. Exitprogrammingmode
Press * Out
Notes:
•Userlocationrepresentsonelocationinmemory
whereanindividualcodeisstored.Ausercodeisstored
init’sownuserlocation.Thereare120userlocations
available.
•Arecordofalluserlocationsmustbemaintainedto
effectivelymanagekeypadandmaintainpropersecurityof
site.Asampleformisavailablefordownloadat
www.rutherfordcontrols.com-Support-Keypads&
Readerssection.
• Themastercodeallowsaccesstotheprogrammingmode
andactivatesthemainrelay.
• Allcodesmustbefollowedbythe*key.
• Codesmaybefrom1-6digitsinlength,anddigitsmaybe
repeated.
• Ifthemastercodeisforgottenordoesnotseemtobe
working,momentarilypushSW1onthecircuitboard,(see
Fig.5forlocation)toenterprogrammingmodeandfollow
steptwofromabovetoprogramanewmastercode.
• IftheyellowLEDlightssolidwhileinprogrammingmode
anerrorhasoccurred.Press*toclear(yellowLEDshould
flash)andstartoverfromstep2or3above.
‡
Themastercodeisalwaysinuserlocation1.
9212i Keypad Installation Instructions (Continued)
2
©2013 RutheRfoRd contRols • www.RutheRfoRdcontRols.com
USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAmBRIDGE, ON N1T 1j6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-mAIl:
[email protected]