©2013 RutheRfoRd contRolswww.RutheRfoRdcontRols.com
USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAmBRIDGE, ON N1T 1j6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-mAIl: [email protected]
IS9212i
Pcn13031
R04/13cA
INSTALLATION
9212i
Stand-Alone Keypad
Instructions
Features:
•4IndependentOutputs
•4IndependentTimers
•AllOutputsAssignablebyCode
•Onboard5AmpFormCRelay
•120Users
•RemoteTriggeringInput
•KeypadProgrammable
Memory
Non-volatileEEPROMmemorymeansyourcodesand
programmingwillbetherewhetheryouremovepowerfor
5minutesor5years.
Programming
Allprogrammingisaccomplishedentirelyfromthe
frontofthekeypad.LEDorSounderguidancemakes
programmingeasy,andchangingcodesamatterof
secondsforanauthorizeduser.
Codes
TheRCIkeypadsallowupto120individualusercodes
tobevalid.Codesmaybefrom1-6digitsinlength
anddigitsmayberepeated.TheMasterCodeisalways
assignedtouserlocationone(1).
Main Relay
Thisisa5Amp(10Ampsurge)Form-Crelaywhichcan
betoggledortimedfrom1to90seconds-bycode.
Auxiliary Outputs
Auxiliaryoutputscanbeindividuallytimedfrom1to90
secondsoractasatoggleswitch,andmaybetriggered
individuallyorincombination-bycode.Thethreeauxiliary
outputsprovidea50mAsinktogroundwhenactivated.
Remote Triggering Input
ThisnormallyopenloopthatbydefaultoperatestheMain
Relayuponactivationandcanbeprogrammedtotrigger
anycombinationofoutputs.Uponamomentaryclosure,
theselectedoutputswillenergizefortheirprogrammed
time.Themainrelay(ifselected)willenergizeforthe
sametimeperiodastheMasterCode.Thisfeatureis
especiallyusefulwhencontrollinganelectriclocking
device.
Keypress Feedback / Audible Keypress
TheRCIkeypadswillacknowledgeakeypressby
momentarilyilluminatingtheyellowLED.Thiscanbe
turnedoffthroughprogramming.
Keypad Active Output
TheRCIkeypadscanbeprogrammedtoenergizea
voltageoutputwheneverakeyistouched.Thiscanbe
usedtoturnonaccessoriessuchaslights,CCTVcamera,
ornotifyaguard.
Auto-Entry
Thisfeatureisusedwhentheneedforthecodenotto
befollowedbythe*keyisdesired.Theuseronlyneeds
toentertheircodenumberandtherelaywillactivatefor
theprogrammedrelaytime.Tousethisfeature,theuser
codesmustbethesamelengthasthemastercode.
Technical Notes:
ToavoidESD(Electro-StaticDischarge)frominterfering
withtheoperationoftheRCIkeypad,groundthenegative
terminalofthekeypadtoearthground.Ifthepower
supplycannotbegrounded,thenthecaseshouldbe
grounded.For24VDCoperation,removejumperJ2(see
Fig.5).
Packing Checklist:
9212iKeypad
Ten(10)ConductorWiringHarness(1)
SlottedScrews(2)
SecurityScrews(2)
Installation
Diode(1)
NOTE:Aswithanyelectronicproduct,the9212imaybesubjecttoirregularitiesintheACpowerline.Thiscancausemalfunctionorunstableoperation.
Connectingthe9212itoasuitableDCpowersupplywilllimittheeffectsofACfluctuationonthekeypad.
Voltage Current Rating Temperature Output
12-24VAC/VDC @12VDC 8mAtyp–35mAw/relayenergized -20°Fto130°F(-28°Cto54°C) Mainrelay:5A;form-C@24VDC;10Asurge
@24VDC 16mAtyp–45mAw/relayenergized Outputs2-4are50mAnegvoltageoutputs
Testing the 9212i Keypad
1. Connectthepositive(+)leadofyourpowersupply
totheterminalstrip(TS1)+Vinput.
2. Connectthenegative(-)leadofyourpower
supplytotheterminalstrip(TS1)-Vinput.
3. Turnonyourpowersupply.
4. Press7890#123456*.Ifall12keypresseshave
beenverified,thekeypadwillenterselftestmode.
TheyellowLEDwillflashthreetimes,thenlight
orsoundcontinuouslyfor3seconds.Ifthese
responsesdonothappen,trythetestmodeagain
andthencalltechsupport.Note:selftestmode
canbeusedwhentroubleshootingakeypadinthe
field.Ifyoudonotgetthecontinuouslightthenthe
memoryhasbeencorruptandshouldbe
re-programmedwiththe46command
(seeoption#18).
5. Enterthemastercodeof1234*.Therelaywill
energize.Refertoprogrammingsectiontoprogram
yourkeypad.
Note:The9212ikeypadmaybeprogrammedinyourshop
orattheinstallationsite.Programmedinformationisstored
innon-volatilememorysoitwillnotbelostifpoweris
removed.
RCI Keypad Defaults
RCIkeypadsaredesignedforeasyinstallationina
minimumamountoftime.Thefollowingdefaultshave
beenfactoryprogrammed:
MasterCode(user1) 1234*
MainRelaywillenergizefor 5 seconds
AuxiliaryOutputswillenergizefor 5 seconds
Panicwillenergize Output 4
KeypadActiveOutput Off
RemoteTriggeringInputwillenergize Main Relay
KeypressFeedback On
LEDonwhenpoweredup RED
LEDonwhenrelayisactivated GREEN
Ifdefaultsmustbechangedoradditionalfunctionsare
desired,pleaserefertotheProgrammingOptionschart
afteryouarefamiliarwiththeProgrammingsection.
Programming
1. Enterprogrammingmode YellowLED
Press 99#(mastercode)* Flashesslowly
2. Tochangemastercode
Press 1#(newmastercode)* Flashesfast
Repeat(newmastercode)* Flashesslowly
Ifmainrelaytimemustbechanged,substituteoption2
fromProgrammingOptionschartforstepabove.
3. Toadd/changesecondcode
Press 2#(newusercode)* Flashesfast
Repeat (newusercode)* Flashesslowly
4. Toadd/changethirdcode
Press 3#(newusercode)* Flashesfast
Repeat (newusercode)* Flashesslowly
5. Upto120codesmaybeaddedinthisfashion
6. Exitprogrammingmode
Press * Out
Notes:
•Userlocationrepresentsonelocationinmemory
whereanindividualcodeisstored.Ausercodeisstored
init’sownuserlocation.Thereare120userlocations
available.
•Arecordofalluserlocationsmustbemaintainedto
effectivelymanagekeypadandmaintainpropersecurityof
site.Asampleformisavailablefordownloadat
www.rutherfordcontrols.com-Support-Keypads&
Readerssection.
• Themastercodeallowsaccesstotheprogrammingmode
andactivatesthemainrelay.
• Allcodesmustbefollowedbythe*key.
• Codesmaybefrom1-6digitsinlength,anddigitsmaybe
repeated.
• Ifthemastercodeisforgottenordoesnotseemtobe
working,momentarilypushSW1onthecircuitboard,(see
Fig.5forlocation)toenterprogrammingmodeandfollow
steptwofromabovetoprogramanewmastercode.
• IftheyellowLEDlightssolidwhileinprogrammingmode
anerrorhasoccurred.Press*toclear(yellowLEDshould
flash)andstartoverfromstep2or3above.
Themastercodeisalwaysinuserlocation1.
9212i Keypad Installation Instructions (Continued)
2
©2013 RutheRfoRd contRolswww.RutheRfoRdcontRols.com
USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAmBRIDGE, ON N1T 1j6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-mAIl: [email protected]
Programming Options Chart
Ifthepre-programmeddefaultvaluesmustbechangedoradditionalfunctionsaredesired,thefollowingoptions
maybeprogrammed.
ENTER PROGRAMMING MODE
1
PRESS 99 # (MASTER CODE) *
Eachofthefollowingoptionscanonlybechangedafterthekeypadhasbeenputintoprogrammingmode(above).
1. Changemastercode/setmainrelaytime
2
Press (RelayTime)#1#(newcode)*(repeatcode)*
e.g.Mastercodeof4321/relaytimeof10sec Press 10#1#4321*4321*
2. Add/changeusercode Press (userlocation)#(newcode)*(repeatcode)*
3. Add/changeusercodewithadifferentoutput Press (RelayTime)#(userlocation)#(newcode)*
timeonmainrelay
2
(repeatcode)*
4. Deleteusercodes Press (userlocation)#**
5. Setoutput2time
2
Press 12#(RelayTime)#0#**
6. Setoutput3time
2
Press 13#(RelayTime)#0#**
7. Setoutput4time
2
Press 14#(RelayTime)#0#**
8. SetoutputsforRemoteTriggeringInput Press 17#(outputs:.ie.1,2or2,3etc.)#0#**
Note:0=nooutputs
9. SetoutputsforPanic
3
Press 18#(outputs:i.e.1,2or2,3etc.)#0#**
Note0=nooutputs
10. Turnkeypressfeedback/on Press 30#0#1#**
11. Turnkeypressfeedback/off Press 30#0#0#**
12. TurnyellowLED/sounderOnwithrelay Press 30#1#1#**
13. TurnyellowLED/sounderOffwithrelay. Press 30#1#0#**
14. Turnautoentryon Press 30#2#1#**
15. Turnautoentryoff Press 30#2#0#**
16. Turnkeypadactiveoutputon
4
Press 43#0#99#**
17. Turnkeypadactiveoff Press 43#0#00#**
18. Erasekeypadmemory/resetdefaults Press 46#00000#00000#**
19.Energizeselectedoutput(s)withausercode
5
Press 59#(outputs:i.e.1,2or2,3etc.)#
(userlocation)#(newcode)*(repeatcode)*
e.g.User2;codeof4321*;energizeoutputs2&3 Press 59#23#02#4321*4321*
Notes:
1
Ifthemastercodeisforgottenordoesnotseemtobeworking,momentarilypushSW1onthecircuitboard,
(seeFig.5forlocation)toenterprogrammingmodeandfollowsteptwofromabovetoprogramanewmaster
code.
2
Relaytimemustalwaysberepresentedby2digits.Example:5seconds=05.Latching/toggleisaccomplished
byenteringatimeof00.
3
Ifselected,panicwilloperatebypressingthe*and#simultaneously.Panicoperatesfor1secondandis
defaultedtooutput4.
4
Keypadactiveisanegativevoltageoutput(sink)availableonterminal(orwire)markedWB(seewiringdiagrams
forlocation).
5
Thisfeatureisnotavailablewiththemastercode.
9212i Keypad Installation Instructions (Continued)
©2013 RutheRfoRd contRolswww.RutheRfoRdcontRols.com
USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAmBRIDGE, ON N1T 1j6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-mAIl: [email protected]
3
9212i Keypad Installation Instructions (Continued)
TS1
V+ V- C N/O
+
White/Red
Red
Common
N/C
N/O
Note: See 9212i W
iring Harness details (Fig. 6)
for explanation of Output conductors.
N/C
Fig. 4WiringanAccessoryRelay
Brown
+
Exit Button
(N/O)
TS1
V+ V- N/C C N/O
White/Orange
Fig. 2Basicaccesscontrolwithanelectricstrike
Electromagnetic Lock
+
Exit Button
(N/O)
TS1
V+ V- N/C C N/O
Brown
White/Orange
Fig. 1Basicaccesscontrolw/anelectromagneticlock
+
Exit Button
To Alarm Panel
Closed Circuit Loop
COM N/O
(N/O)
TS1
V+ V- N/C C N/O
Brown
White/Orange
Fig. 3ShuntingaNormallyClosed(N/C)Zone
4
©2013 RutheRfoRd contRolswww.RutheRfoRdcontRols.com
USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAmBRIDGE, ON N1T 1j6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-mAIl: [email protected]
9212i Keypad Installation Instructions (Continued)
©2013 RutheRfoRd contRolswww.RutheRfoRdcontRols.com
USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAmBRIDGE, ON N1T 1j6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-mAIl: [email protected]
WHITE
ORANGE
WHITE/ORANGE
BROWN
WHITE/YELLOW
BLACK
RED
WHITE/BLACK
WHITE/RED
WHITE/BLUE
WARNING: Plug this harness in with the leads
facing down! Permanent damage may result if
incorrectly inserted.
Fig. 69212iWiringHarness.
WARNING:Plugthisharnessinwiththeleadsfacingdown!Permanentdamagemayresultifincorrectlyinserted.
Wire Color Wire Function
White NotUsed
White/Blue Output3(50mAsinktoground)
White/Red Output2(50mAsinktoground)
Orange Output4/panic(50mAsinktoground)
Brown RemoteTriggeringInput(REX)
White/Orange RemoteTriggeringInput(REX)
White/Black K(in)KeypadActive
White/Yellow K(out)
Black Ground(outputsonly)
Red V+Filtered(outputsonly)
5
- Yellow LED
+ Yellow LED
-
-
+
+
Green LED
Red LED
Green LED
Red LED
J2 – remove
jumper for
24V operation
TS1 Terminal Strip
SW1 Program
Switch
V+ V- N/C C N/O
Fig. 59212iCircuitBoard