INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY
DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
Installation and servicing of this equipment should be performed by qualified service personnel only.
Ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
Do not mount near gas or electrical heaters.
Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by
unauthorized personnel.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Any
modification or use of non-original components will void the warranty and product liability.
Do not use this equipment for other than intended use.
800.533.3948 www.barronltg.com
1
The LED Canopy light is designed to be mounted to a recessed J-box on celling wall or can be pendant mounted using
optional pendant mount adapter. Please consult with your lighting designer to obtain the optimum installation location.
Note: The TLED-C is not designed to be wired using surface mounted conduit.
20070004 REV 5 09/15
TLED-C/TC
1: Remove 4 cover plate screws and disconnect LED
driver connectors.
2: Mount cover plate to junction box using the
provided slots.
Electrical wire opening or Pendant mount hole.
INSTALLATION INSTRUCTIONS
800.533.3948 www.barronltg.com
2
5: Mount bottom enclosure to the cover plate with 4 screws.
OPERATION
The LED Canopy requires no special handling. Power “ON” or power “Cycle” requirements. We do recommend routine
inspections to visually verify that the fixtures are “ON” and emitting light. Any unit that is not functioning should be
inspected and repaired or replaced.
TROUBLE SHOOTING
Canopy does not turn “ON”
1. Check incoming voltage to LED driver. Must be at least a minimum of 120VAC and no greater than 277VAC.
2. Are all the LEDs on the light engine “OFF”? If so, LED driver may be defective. Using a voltmeter, check to see if
voltage is present at the output of power supply. If low or no voltage, then replace power supply.
3. If any individual LEDs are “OFF” the LED light engine is defective. Please have the serial number off the light engine
available when you contact technical support.
20070004 REV 5 09/15
WARNING!
Do not allow the TLED-C to
hang from the harness. This
may cause damage to the
circuit.
3: Electrical connection should be made inside junction box. Cap all unused leads to prevent shorting.
This fixture auto adjusts for voltages between 120VAC - 277VAC.
4: Connect the LED driver harness(s) to the LED light engine.
TLED-C/TC
– OUT
+
OUT
– DIM
+
DIM
– OUT
+
OUT
– DIM
+
DIM
CONNECT TO 0-10V
DIMMING CONTROL
CONNECT TO 0-10V
DIMMING CONTROL
CONNECT TO AC POWER
LED
DRIVER
LINE
LINE NEUTRAL
NEUTRAL
LED
DRIVER
WHI
BLK
BLK
WHI
GRN
GND
GRN
SP
GND
GND
LINE
NEUTRAL
SURGE PROTECTION
SP
LED
LIGHT
ENGINE
black - line
white - neutral
green - ground
WARNING!
Do not allow the unit to
hang from the harness.
This may cause damage
to the circult.
Safety Cable
Fig. 2
TLED-RC
INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY
DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
Installation and servicing of this equipment should be performed by qualified service personnel only.
Ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
Do not mount near gas or electrical heaters.
Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by
unauthorized personnel.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Any
modification or use of non-original components will void the warranty and product liability.
Do not use this equipment for other than intended use.
800.533.3948 www.barronltg.com
1
20070009 REV 3 05/15
INSTALLATION INSTRUCTIONS
1. Remove wireway cover by loosing 4 screws. Feed
supply wires through knockout and secure with fitting or
bushing per local code. (Fig.1)
2. Fixture is supplied with a safety cable. Attach the
safety cable in a secure place within the cut out opening
to support the fixture for ease of wiring. Safety cable can
be left secured after installation is complete. (Fig. 2)
The Recessed Canopy is designed to be recessed mounted in walls, ceilings, or overhead canopies. Please consult
your lighting designer to obtain the optimum installation location.
Wire Way
Cover Screws
Wire Way
Cover
Supply Wires
Fig. 1
TLED-RC
INSTALLATION INSTRUCTIONS
800.533.3948 www.barronltg.com
220070009 REV 3 05/15
3. Electrical connections should be made inside wireway cover. Cap all unused leads to prevent shorting.
This fixture auto adjust for voltage between 120VAC - 277VAC.
4. Secure wireway cover retightening 4 screws. Make sure no wires are being pinched when securing
cover wireway.
– OUT
+
OUT
– DIM
+
DIM
– OUT
+
OUT
– DIM
+
DIM
CONNECT TO 0-10V
DIMMING CONTROL
CONNECT TO 0-10V
DIMMING CONTROL
CONNECT TO AC POWER
LED
DRIVER
LINE
LINE NEUTRAL
NEUTRAL
LED
DRIVER
WHI
BLK
BLK
WHI
GRN
GND
GRN
SP
GND
GND
LINE
NEUTRAL
SURGE PROTECTION
SP
LED
LIGHT
ENGINE
black - line
white - neutral
green - ground
Wire Way
Cover Screws
TLED-RC
INSTALLATION INSTRUCTIONS
800.533.3948 www.barronltg.com
320070009 REV 3 05/15
5. Position fixture trim plate in opening. The trim plate can be securely fastened using the (4) Corner hole positions to
the finished surface material using appropritate anchors/hardware. (NOT SUPPLIED) (Fig. 4)
OPERATION
The Canopy requires no special handling. Power “ON” or power “Cycle” requirements. We do recommend routine
inspections to visually verify that the fixtures are “ON” and emitting light. Any unit that is not functioning should be
inspected and repaired or replaced.
TROUBLE SHOOTING
Canopy does not turn “ON”
1. Check incoming voltage to LED driver. Must be at least a minimum of 120VAC and no greater than 277VAC.
2. Are all the LEDs on the light engine “OFF”? If so, LED driver may be defective. Using a voltmeter, check to see if
voltage is present at the output of power supply. If low or no voltage, then replace power supply.
3. If any individual LEDs are “OFF” the LED light engine is defective. Please have the serial number off the light
engine available when you contact technical support.
Fig. 4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

BARRON TLED-C-LG Series Low Glare Canopy Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI