Replacement of Motor Print
Technical User Guide 432986 - 432987 - 432988 - 432989 3
1.3 Calibration
The mechanical end stop and inner position on the actuator must be the same.
Prior to calibration, mount one inlet for air intake on the drawbar to the maximum open position.
The outer position inlet for air intake is closed.
The actuator cannot run in auto mode until calibration has been completed.
1. Press MAN.
2. Press SET and hold for 5 seconds until the yellow LED flashing.
3. Press IN or OUT until the actuator is in the desired outer/inner position.
4. Press IN or OUT to stop.
5. To save the position press SET and hold until the red LED flashes three times.
6. Press IN or OUT until the actuator is in the desired outer/inner position.
7. Press IN or OUT to stop.
8. To save the position press SET and hold until the red LED flashes three times.
9. Red LED is constantly on.
The calibration is complete. The actuator is in manual mode.