USERMANUALFOR
DMX4i/DMX4o
LightingControlMultiplexer
Thispageintentionallyleftblank
1
WarningforYourProtection
1.Readtheseinstructions
2.Keeptheseinstructions
3.Heedallwarnings
4.Followallinstructions
5.Donotusethisapparatusnearwater.
6.Cleanonlywithadrycloth.
7.Donotblockanyoftheventilationopenings.Installinaccordancewiththemanufacturer’sinstructions.
8.Donotinstall
nearanyheatsourcessuchasradiators,heatregisters,stoves,orotherapparatus(includingamplifiers)that
produceheat.
9.Donotdefeatthesafetypurposeofthepolarizedorgroundingtypeplug.Apolarizedplughastwobladeswithonewider
thantheother.Agroundingtypeplughastwobladesandathirdgroundingprong.Thewidebladeorthethirdprongare
providedforyoursafety.Iftheprovidedplugdoesnotfitintoyouroutlet,consultanelectricianforreplacementofthe
obsoleteoutlet.
10.Protectthepowercordfrombeingwalkedonorpinched,particularlyatplugs,
conveniencereceptacles,andthepoint
wheretheyexitfromtheapparatus.
11.Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
12.Useonlywiththecart,stand,tripod,bracket,ortablespecifiedbythemanufacturer,orsoldwith
theapparatus.Whenacartisused,usecautionwhenmovingthecart/apparatus
combinationtoavoid
injuryfromtipover.
13.Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
14.Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushasbeen
damagedinanyway,suchaspowersupplycordorplugisdamaged,
liquidhasbeenspilledorobjectshavefallenintothe
apparatus,theapparatushasbeenexposedtorainormoisture,doesnotoperatenormally,orhasbeendropped.
Theapparatusshallnotbeexposedtodrippingorsplashing.Noobjectsfilledwithliquids,suchasvases,shallbeplacedonthe
apparatus.
“WARNINGToreducetheriskoffireorelectricshock,donotexposethisapparatustorainormoisture.”
GeneralInstallationInstructions
Pleaseconsiderbesidesthesegeneralinstructionsalsoanyproductspecificinstructionsinthe“Installation”chapte rofthis
manual.
2
Registration
BesuretoregisteryourLightViperproduct,eitherbyfillingintheenclosedRegistrationCardorbycompletingtheonline
registrationformatourWebsite:
http://lightviper.com/register.aspx
Ifyoudoso,FiberPlexcancontactyouwithanyupdateinformation.Asenhancementsandupgradesaredeveloped,youwillbe
contactedat
theregistrationaddress.Pleasereadthismanual‐ifyoucallfortechnicalsupport,we’llassumethatyouhave.
PleaseaddressanyinquiriestoyourdealerordirectlytoFiberPlexat:
FiberPlexInc.
10840412GuilfordRd.
AnnapolisJunction,MD20701
301.604.0100Fax:301.604.0773
Warranty,ServiceandTermsandCon ditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsofSale’.Thisdocument
isavailableonfiberplex.com
orcanbeobtainedbyrequestingitfrom[email protected]orcalling301.604.0100.
3
Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterialcanberecycled.
Recyclingpackingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedtodisposeofthetransportpacking
materials,pleasetrytouserecyclablemeans.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellasmaterialsthatmustbedisposedofprofessionally.Pleasereturn
yourusedequipmentviaanauthorizedspecialistdealerorviathepublicwastedisposalsystem,ensuringanymaterialthatcan
berecycledis.Pleasetakecarethatyourused
equipmentcannotbeabused.Afterhavingdisconnectedyourusedequipment
fromthemainssupply,makesurethatthemainsconnectorandthemainscablearemadeuseless.
DeclarationsofConformity
ClassAEquipment‐FCCNotice
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttoPart15oftheFCC
Rules.Theselimitsaredesignedtoprovideareasonableprotectionagainstharmfulinterferencewhentheequipmentis
operatedinacommercial
environment.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradiocommunications.
Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterference,inwhichcasetheuserwillberequired
tocorrecttheinterferenceathisownexpense.
Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeofpublication.
However,noresponsibilityistakenbyusforinaccuracies,errors,oromissions,norisanyliabilityassumedforanylossor
damageresultingeitherdirectlyorindirectlyfromuseoftheinformationcontainedwithinit.

4
Introduction
CongratulationsonyourpurchaseofaLightVipersystem.LightViperproductsaredesigned,engineeredandmanufacturedby
FiberPlexInc.,expertsinfiberopticswithdecadesofexperience.Ourworkinaudioanddatacommunicationsproductsis
knowninUSgovernmentapplicationsworldwide.LightViperproductscombineourpioneeringtechnologywiththehighest
standardsinaudioengineering.
TheLightViperSystem
YouhavepurchasedtheLightViperDMX4.Insteadoftraditionalheavymulticonductorcoppercable,
LightViperfiberopticsystemsutilizelightweight,flexible,militarytacticalgradefiberopticcableor
duplexPVCandplenumratedfiberforinstallationuse.TheDMX4iandDMX4ounitsallowyousend
(4)universesofDMXlightingcontrol
throughyourLightVipersnakesystem(FOHtoStageonly)via
thesamefiberopticcablethatcarriesyour(8)audioreturns.
TheFiberAdvantage
Fiberopticsoffermanyadvantagesovercopper:
Transmitslightratherthanelectrons
Transmissionovergreaterdistances(morethan2Km[1.25mile])
Completeelectricalisolation
ImmunitytoRFIandEMI
Eliminatesgroundloopproblems
Canberoutedoverhead,throughwalls,orunderground
Avoids
foottrafficwhilemaintainingaesthetics
FunctionalConsiderations
TheLightViperDMX4isanaccessoryitemintendedforusewithanyLightViper1832,4832or1808system.Theseunitswill
onlyworkwhenproperlyconnectedtoanexistingLightViperfiberopticsystem.TheLightViperDMX4unitscontainnouser
serviceableparts.PleasecontactFiberplexdirectlywithanyserviceissues.
StandardComponents
DMX4iTheDMX4icontains(4)3pinfemaleXLRconnectors(inputs),(4)5pinfemaleXLRconnectors(inputs),asingle
femaleDB9connector(inputs),andasingleRJ45EtherCon
connector.AllDMXcontrolinputsareconnectedtothisunit.
DMX4oTheDMX4ocontains(4)3pinmaleXLR
connectors(outputs),(4)5pinmaleXLRconnectors(outputs),asinglemale
DB9connector(output),andasingleRJ45EtherCon
connector.AllDMXcontrolinputsareconnectedtothisunit.
DMXinterfacecablesDMXcablesarerequiredtoinputDMXcontrolintotheDMX4iandoutputDMXcontrolfrom
the
DMX4o.ThesecablesarenotsuppliedwiththeDMX4unitsandcanbepurchasedseparatelyfromyourlocallightingormusic
retailer.TheDMX4iandDMX4ocanuseeither(3)pinor(5)pinDMXcables.ThissystemoffersONEWAYcontrolonlyfrom
FOHtostage.
CAT5Jumpers
CAT5jumpersarerequiredtoconnecttheDMX4iandDMX4ototheLightVipertransportsystem.These
jumpersarenotsuppliedwiththeDMX4units.Werecommend“Ruggedized”CAT5connectorsbeusedinsituationswhere
thesecablesmaybepronetobeingsteppedonorpulledwhileinuse.
5
GettingStarted
Toconnect&useyourDMX4unitspleasefollowthesesteps:
1.
PlacetheDMX4iasnearaspossibletotheVIM1832mixerboxorVIMMY32Scards.ConnecttheDMXitoyourVIM
1832mixerboxorVIMMY32Scardsusing“ruggedized”CAT5cable.
2.
PlacetheDMX4ounit
onstageasnearaspossibletothelightingfixturesyouwillbecontrolling.ConnecttheDMXoto
yourVIS1832mixerbox,VIS4832orVIM0808unitusing“ruggedized”CAT5cable.
3.
ConnecttheDMXcontrolbetweenthelightingcontrollerandtheDMX4i.
4.
ConnecttheDMX4oto
thelightingfixturesbeingcontrolled.
5.
Testthesystemtoensurecontrolisworking
Note:TheDMX4iandDMX4oareidenticalwiththeexception thatDMXisinputtotheDMX4iandoutput
fromtheDMX4o.
With that in mind, the description below pertains to both units.TheDMX4oisidentical
excepttheXLRandDB9connectorsarefemaleasitisprovidingDMXoutputfromtheLightVipersystem.
DMX4i/DMX4o
(3)pinXLRconnectors‐ThisiswheretheDMXcontrolisinputintoDMX4iandoutputfromthe DMX4o.
(5)pinXLRconnectors‐ThisisalternativelywheretheDMXcontrolisinputintotheDMX4iandoutputfromtheDMX4o.
DB9ConnectorThisiswheretheYamahacontrolprotocolcanbeinputtotheDMX4iandoutputfromtheDMX4oviaa9pin
crossovercable.
RJ45EtherConConnectorThisconnectorprovidestheinterfacebetweentheDMX4iandtheVIM1832,VIMMY32SorVIM1808,
andbetweentheDMX4oandtheVIS1832,VIS4832or
VIM0808.
SyncLEDThisLEDisunlitwhen noACpowerispresentandgreenwhentheunitispoweredandinsync.BoththeDMX4iandDMX4o
receivetheirpowerfromtheLightViperunitstheyareconnectedtothroughthisRJ45connector.
Important:Eachchannelhasaselectionofconnectors.Onlyoneconnectorperchannelmaybeusedatone
time.ThisincludestheD9HAcontrolconnectoronchannel4.
1
2
3
4
5
1 2
3
4
5
DMX4i (Input)
DMX4o (Output)
1 2
3
4
5
6
LightViperDMX4i/DMX4oSpecification s
1. General Specifications
Operating Temp
0 to +50°C ambient temperature.
Sync LED
LED (green) indicates the RJ45 link is OK, LED (red) indicates problem with RJ45 link, LED (off) indicates no power.
AC Power
N/A
Max Current Rating
VIM-MY32M 3.5 W from RJ45 host unit
Control
RJ-45 connector for logic level control, CMOS or TTL at 2 MHz max per channel.
DMX Data
Single Direction, fully complies with the USITT DMX512 Specification
Dimensions
DMX4
1 Rack Unit X 6.5" (165mm) Deep
Weight
DMX4 9 lbs (4 Kg) Packed for shipment
DMX Connector Pin Outs
3 Pin XLR (typ M/F)
1. Gnd
2. Data -
3. Data +
5 Pin XLR (typ M/F)
1. Gnd
2. Data -
3. Data +
4. N/C
5. N/C
HA Connector Pin Outs
1. Unused
2. RX -
3. TX -
4. TX +
5. Ground
6. RX +
7. Unused
8. Unused
9. Unused
Control Circuits RJ-45 Pin Outs
1. GND
2. TX1
3. TX2
4. TX3
5. RX1
6. RX2
7. RX3
8. VCC +5VDC
8
Thispageintentionallyleftblank
LVDXUM8
/
2011
18040-412 Guilford Rd. • Annapolis Junction, MD 20701
fiberplex.com • [email protected]
• 301.604.0100
/