Optimus XELLIP ROUTEUR User manual

Type
User manual
1 XELLIP Server - 604-0004C
IP
TECHNICAL SHEET
XELLIP
System
ROUTER SERVER
Installation
Programming
Connection Use
INTRODUCTION
Product reference: 540,000
The XELLIP Router Server is integrated in a complete and powerful Full IP multimedia system. It is native SIP, and
includes the following features:
Manage up to 20 SIP stations (configuration, visualization, saving)
Manage audio and video calls
Manage call groups
Manage call zones
Manage paging groups
Make SIP Trunk (SIP interconnection of two SIP systems)
Configure dialing rules
Configure external extensions
User management
It can be configured, monitored and operated from any browser, with its embedded web server
System administration.
It includes a POE power supply
Secure the Ethernet network by using the 802.1X protocol (Radius
Integrate SNMP protocol (Simple Network Management Protocol)
2 XELLIP Server - 604-0004C
CONNECTION
15-30VDC Power supply
RJ45: ETHERNET & 10/100 POE
USB (NC)
Logic input
Relay output
R
T
E C
NO
NC
C
Connecting the power supply
A 15-30V power supply is required. The device can be powered by the POE network (option).
Connecting the IP network
The connection is done by an Ethernet 10/100 Mbps RJ45.
FUNCTIONS
General Server Functions
The Router Server was designed to administer and manage up to 20 stations. Stations and SIP softphones can be managed.
Viewing the server status: this gives an overall view of the stations and of their status.
General configuration: we can define the number of digits for extensions, the call times, priorities, etc.
Defining stations: this menu is for adding, modifying, or deleting a station.
Server configuration: In this menu, we can add, modify or delete a server.
Call group: We can configure several call groups. Every group may contain several stations. When a group
is called, the first one that replies enters into a conversation, and the call disappears from others stations of
the group.
Call areas: used for managing overflows. In a call area, if a station does not reply, the call is then sent to
other stations.
Paging Group: used for configuring paging call groups. If they receive a call, members of a paging group
then pick up and can all listen to the conversation.
Functions of interconnection with external systems: SIP Trunk
Configuration of SIP Trunk connection either as client or as server.
Set dialing rules to be used to make calls to the registered stations on external systems.
Define external extensions to identify extensions on external servers by giving them a local number. These
extensions are then used when configuring overflow or creating call groups.
User function of the Web server
The Web server of the station allows granting, modifying or deleting the rights to the users by specifying their login,
password and language.
Administration management SNMP
The station includes an agent SNMP (Simple Network Management Protocol) to respond to SNMP requests and to send
notifications (traps) to a SNMP manager.
From web pages, you can:
Configure different community (read / write)
Configure system data (“sysContact” and “sysLocation”)
Configure notifications (recipient, community ...)
Download “MIB Castel”
It supports SNMPv1 and SNMPv2c versions.
3 XELLIP Server - 604-0004C
INSTALLATION
Wall installation:
Fix the base with four screws of 3-3.5 diameter max (see the diagram below for positioning).
3
3
=
8
2
,
5
=
4
Ø
3
,
5
=
1
0
5
=
=
9
5
=
1
3
7
85 26
CONFIGURATION
The station is delivered by default with a DHCP address. If no DHCP server is present, then the
station will take a fixed IP address of domain IP4All: 169.254.xx.xx. The IP address of station will
be found by the application CastelIPSearch.
The username is: admin
Password: admin
Connect the Server to the IP network. Then open a browser on your PC and type the address of the
device: https://IP address for station
Accept the certificate.
4 XELLIP Server - 604-0004C
Type the username (admin) and the password (admin) and "send"
Press "complete display": this gives you access to all available functions
The functions are explained in more detail in online help on the server webpages.
TECHNICAL PROPERTIES
Compliance with European standards
-Security rules according to norm EN 60950.
-CEM transmission according to norm EN 55022 class B.
-CEM immunity according to norm EN 55024.
Mechanical properties
-IP40 degree of protection according to EN 60529.
-Case painted in light grey RAL 7035
-Dimensions: H 137mm x L 105mm x W 33mm Weight:
400g
-Protruding installation.
General electrical properties
-Class 3 protection against electric shocks according to EN
60950.
-Storage temperature: -20° / + 70° C.
-Relative humidity < 90%.
-Operating temperature: -20 to + 50° C.
-Power supply: 15VDC (15V to 30V).
-Consumption: 15V 250 mA
Inputs:
-1 protected and filtered digital input.
-Acquisition speed 5Hz (200ms)
4K7 closed contact input impedance
22K open contact input impedance
Output:
-Voltage free relay output
-42.4 Vac/60 Vdc/5A/150VA relay cut power
-Maximum frequency is 5 Hz (Minimum commutation
time: 200ms)
Audio Codec:
-G711 M/A
-GSM
-G722
Video Codec:
-H263
-H263-1998
-H264
DTMF:
-RFC-2833
-SIP INFO
10/100 Mbit Ethernet network:
-Fixed IP or DHCP
-WIFI network that complies with IEEE 802.11b/g
standards
-POE class2 that complies with IEEE 802.3af
standards
-802.1X protocol (Radius)
-SNMP v1 & v2c
Environmental protection
Dispose of this product in
compliance with environmental
preservation regulations
CASTEL
Z.I. de Saint Lambert des levées - 49412 SAUMUR Cedex - FRANCE
www.castel.fr - Tel: +33 2.41.40.41.40 - Fax: +33 2.41.40.41.49
This document is not contractual. The manufacturer reserves the right to apply any modifications that it deems useful, without any notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Optimus XELLIP ROUTEUR User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI