TALA Brass Triple Pendant User guide

Type
User guide

TALA Brass Triple Pendant lets you tailor your lighting to your needs. With a minimum cord length of 300mm and adjustable cord length, it can be used in various settings. Perfect for above a coffee table, side table, kitchen island, or stairwell, the recommended minimum distances between pendants depend on the bulb style. Use a soft dry cloth for cleaning to avoid damaging the finish.

TALA Brass Triple Pendant lets you tailor your lighting to your needs. With a minimum cord length of 300mm and adjustable cord length, it can be used in various settings. Perfect for above a coffee table, side table, kitchen island, or stairwell, the recommended minimum distances between pendants depend on the bulb style. Use a soft dry cloth for cleaning to avoid damaging the finish.

EU/UK
Thoughtful lighting, responsibly designed in London.
Thank you for making the switch to Tala.
Discover the full Tala family at tala.co.uk
BEFORE STARTING
We advise the tting of our Canopy and Pendant to be performed by
a qualied electrician. Please read through these instructions before
commencing work, and keep them for future reference. Please take
extreme care when carrying out these instructions.
IMPORTANT
This light tting must be connected to the supply earth. If your lighting
circuit does not have an earth, ask a qualied electrician to provide
an earth facility. This light tting is suitable for indoor use only. This
tting operates on 240V mains voltage. Please visit our website to see
our recommended dimmers.
WARNING
Always switch off electricity supply at the mains during installation
and maintenance. We recommend that the fuse is withdrawn or the
circuit breaker is switched off whilst work is in progress. Do not just
turn off at the wall switch. All ttings must be installed in accordance
with current Building Regulations and IEE Wiring Regulations.
RECOMMENDED EQUIPMENT
- Small at head screwdriver
- Wire strippers
- Insulation tape
- M10 (17mm) (5/8IN) spanner or Adjustable spanner
Further equipment may be required for xing to your ceiling.
INSTALLATION GUIDE
Triple Pendant
IP20 220 - 240V
SKU - CP-WHT-SML-GP-01-EU
SKU - CP-WHT-SML-OP-01-EU
SKU - CP-WHT-SML-BP-01-EU
SKU - CP-WHT-SML-WP-01-EU SKU - CP-BLK-SML-GP-01-EU
SKU - CP-BLK-SML-OP-01-EU
SKU - CP-BLK-SML-BP-01-EU
SKU - CP-BLK-SML-WP-01-EU
TRIPLE PENDANT - PROVIDED COMPONENTS
x1 M10,
Internal tooth washer
x1 Ceiling plate
A
A
x1 Nut
C
B
B
x1 Ceiling Bracket
D
x3 Tala Pendants
Oak, Walnut, Brass or Graphite
E
or
E
B
STEP 2
Thread all three pendant cables
though ceiling plate cord grips .
E
B
STEP 1
Attach to the ceiling using screws
and plug. Always choose screws and plugs
that are appropriate for the ceiling.
A
A
Mains supply
Earth
240V
Fixings not included
E
STEP 4
Cut off excess cable and strip wires to
expose the copper core. Maintain all
double insulation.
STEP 3
Pull pendant cables through cord
grips to your desired length. Using a
at head screwdriver, tighten set screws
to secure them.
E
B
B1
B
Earth
B1
E
Mains supply
Earth tag from ceiling bracket
Brown or Red (L)
Blue or Black (N)
Pendants
Pendants
Brown or Red (L)
Pendants
Blue or Black (N)
Junction boxes
not included
Houshold Earth
Earth tag from ceiling plate
240V
240V
B
A
STEP 5
Connect the pendants, plate and mains
wiring as shown.
STEP 7
Screw bulbs into pendants clockwise.
A
C
D
B
STEP 6
Move up onto . Use toother washer
and nut to secure it in place.
Do a nal tighten with the correct spanner.
B A C
E
D
EE
ADJUSTING THE CORD
To adjust the cord to your desired length,
using a at head screw driver, loosen
the grub/set screw and push the
cable up into the ceiling plate.
Secure the cable in place by re-tightening
the grub screw. Maintain all double insulation.
1
1
MINIMUM CORD LENGTH
For all bulbs shortest recomended cord length
is 300mm
A
DISTANCE BETWEEN PENDANTS
Recomended minimum distance
between pendant, dependant on
bulb style, are as follows:
Voronoi I - 150mm
Voronoi II - 200mm
Voronoi III - 350mm
Basalt - 100mm
All other bulbs - 100mm
B
A
B
PENDANT DISPLAY GUIDE
PENDANTS - RECOMMENDED CABLE LENGTHS
SCENARIO 1
Above a coffee or dining table,
or where height is required for
seated tasks
SCENARIO 2
Above side tables, or where
height is required for storage
Minimum Distance
700mm
Minimum Distance
500mm
SCENARIO 3
Above a kitchen island or bar,
or where height is required
for standing tasks
Minimum Distance
800mm
Minimum Distance
2.2m (7 Ft)
SCENARIO 4
Above a stairwell or walkway,
or where height is required
for walking underneath
CARE AND CLEANING
We recommend cleaning with a soft dry cloth. Do not use
abrasive materials as these will damage the nish of the product.
WARRANTY AND AFTER-CARE
This product has a three-year warranty. Within this time
we will replace any parts that have functional defects.
Please report any faults by emailing:
Join the Community
Instagram: @tala | Facebook: talaHQ | Pinterest: TalaLED | Tag: lighttoliveby
Tala Studios, 25B Vyner Street, London E2 9DG | +44 20 3026 3246 | [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

TALA Brass Triple Pendant User guide

Type
User guide

TALA Brass Triple Pendant lets you tailor your lighting to your needs. With a minimum cord length of 300mm and adjustable cord length, it can be used in various settings. Perfect for above a coffee table, side table, kitchen island, or stairwell, the recommended minimum distances between pendants depend on the bulb style. Use a soft dry cloth for cleaning to avoid damaging the finish.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI