Altronix TROVE T2MK7F8PQ Installation guide

Type
Installation guide

Altronix TROVE T2MK7F8PQ is a pre-assembled kit designed for access control and power integration. It includes an enclosure, power supply/charger, fuse-protected network power distribution module, voltage regulator, and dual-input fuse-protected power distribution module. The kit accommodates up to eight Mercury boards for access control, making it suitable for various applications requiring multiple door control.

Altronix TROVE T2MK7F8PQ is a pre-assembled kit designed for access control and power integration. It includes an enclosure, power supply/charger, fuse-protected network power distribution module, voltage regulator, and dual-input fuse-protected power distribution module. The kit accommodates up to eight Mercury boards for access control, making it suitable for various applications requiring multiple door control.

T2MK7F8PQ
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) LINQ8PD - Fuse Protected Networked Power Distribution Module
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fuse Protected Power Distribution Module
Rev. 080118
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
Access & Power Integration
- 2 - T2MK7F8PQ Installation Guide
Overview:
Altronix T2MK7F8PQ Trove Mercury kit is pre-assembled and consists of Trove2M2 enclosure with factory installed Altronix power supply/charger
and sub-assemblies. T2MK7F8PQ kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure.
Configuration Chart:
Altronix
Model Number
120VAC
60Hz
Input
Current
(A)
Power
Supply
Board
Input
Fuse
Rating
Power
Supply
Board
Battery
Fuse
Rating
Nominal DC
Output Voltage
Maximum Supply
Current for Main and
Aux. Outputs on
Power Supply Board
LINQ8PD
Board
Input
Fuse
Rating
LINQ8PD
Board
Output
Fuse
Rating
PDS8
Board
Input
Fuse
Rating
PDS8
Board
Output
Fuse
Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T2MK7F8PQ 4.5 6.3A/
250V
15A/
32V
20.19-
26.4
20.19-
26.4 24VDC @ 9.2A 15A/32V 3A/32V 10A/
32V
3A/
32V
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and
screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws;
level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three
fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the three lower screws and make sure to
tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in
desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the
enclosure approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate
UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Mercury modules to backplane(s), refer to page 3.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow104NB
and corresponding Sub-Assembly Installation Guides for
LINQ8PD, PDS8 and VR6 for further installation instructions.
Hardware:
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Snap On Spacer | 5/16” Pan Head Screw | Lock Nut
T2MK7F8PQ Installation Guide - 3 -
T2MK7F8PQ: Configuration of Mercury Boards:
1. Fasten snap on spacers onto metal pems configuration (A), (B), (C) or (D) of backplane depending on the access controller (Fig. 2, pg. 3).
2. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 2a, pg. 3).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
EP1502, MR52, MR16IN, MR16OUT A
EP2500, MUX8 B
EP1501, MR51e C
MR50 D
Fig. 2
B
B
AB
CC
CC
C
D
D
B
A
A
A
Altronix - eFlow104NB
– DC +– BAT +
L G N
AC FAIL NC C NC C BAT FAIL
+ INP1 - + INP2- +BAT IN- +BAT OUT-
BAT AC
NC C NC C
Altronix - LINQ8PD
+ INP1 --
DM1 +OFF
IN1
IN2
Out1
<1 off 2>
DM1 +
DM2 +
DM2 +
Common (--- )
Common (--- )
+ INP2 --
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
10
10
3
3
3333 33
Out2
<1 off 2>
Out3
<1 off 2>
Out4
<1 off 2>
Out5
<1 off 2>
Out6
<1 off 2>
Out7
<1 off 2>
Out8
<1 off 2>
Altronix - PDS8
Altronix VR6 is mounted under PDS8
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGEREOL NO GND
SUPERVISED RESET
+AUX-
Snap On
Spacer
Mercury Board
Backplane
Pem
Fig. 2a
- 4 - T2MK7F8PQ Installation Guide
Trove2 Enclosure Dimensions (H x W x D approximate):
27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)
6.75” (171.5mm)8.25” (209.5mm)
8.00” (203.2mm)
2.00” (50.8mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
1.25” (31.8mm)
6.25” (158.8mm) 19.80” (502.9mm)
1.00” (25.4mm)
27” (685.8mm)
1.5”
(38.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
3.5”(88.9mm) 3.5”(88.9mm)
21.50” (546.1mm)
5.25” (133.35mm) 5.25” (133.35mm)
6.25” (158.8mm)
1.25”
(31.8mm)
0.85” (21.6mm)
0.5625” (14.3mm)
2.415” (61.3mm)
0.685” (17.4mm)
1.77”
(45mm)
0.885” (22.5mm)
1.125” (28.3mm)
Knockouts
2.00” (50.8mm) 2.00” (50.8mm)
Altronix is not responsible for any typographical errors.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIT2MK7F8PQ I29U
MEMBER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Altronix TROVE T2MK7F8PQ Installation guide

Type
Installation guide

Altronix TROVE T2MK7F8PQ is a pre-assembled kit designed for access control and power integration. It includes an enclosure, power supply/charger, fuse-protected network power distribution module, voltage regulator, and dual-input fuse-protected power distribution module. The kit accommodates up to eight Mercury boards for access control, making it suitable for various applications requiring multiple door control.

Ask a question and I''ll find the answer in the document