Altronix T3VK75F20 Installation guide

Type
Installation guide

Altronix T3VK75F20 is a fully assembled kit designed to integrate access control and power distribution for up to 20 doors. It includes a Trove3 enclosure with a TV3 backplane, one eFlow104NB and one eFlow102NB power supply/charger, two ACM8 and one ACM4 fused access power controllers, one PD8UL fused power distribution module, and one RSB2 rocker switch bracket with two switches. With its fused outputs and support for various HID VertX® modules, this kit offers reliable power and access control solutions for a wide range of applications.

Altronix T3VK75F20 is a fully assembled kit designed to integrate access control and power distribution for up to 20 doors. It includes a Trove3 enclosure with a TV3 backplane, one eFlow104NB and one eFlow102NB power supply/charger, two ACM8 and one ACM4 fused access power controllers, one PD8UL fused power distribution module, and one RSB2 rocker switch bracket with two switches. With its fused outputs and support for various HID VertX® modules, this kit offers reliable power and access control solutions for a wide range of applications.

T1VK3F4
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TV1 Altronix/HID VertX® backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
T2VK7F8
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TV2 Altronix/HID VertX® backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) ACM8 - Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
T3VK75F20
20 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove3 enclosure with TV3 Altronix/HID VertX® backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- Two (2) ACM8 - Fused Access Power Controllers
- One (1) ACM4 - Fused Access Power Controller
- One (1) PD8UL - Fused Power Distribution Module
- One (1) RSB2 - Rocker Switch Bracket with Two (2) Switches
(Not evaluated by UL)
Access & Power Integration
Altronix/HID VertX® Kits
Models Include:
Rev. TVK_042519
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - Trove HID VertX (Fuse) Kits Installation Guide
Overview:
Altronix Trove HID VertX® kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/
chargers and sub-assemblies. All kits accommodate a variety of HID VertX® modules for up to four (T1VK3F4), eight (T2VK7F8) or twenty
(T3VK75F20) doors in a single enclosure.
Configuration Chart:
Altronix
Model
Number
120VAC 60Hz
Input Current (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
Maximum Supply
Current for Main
and Aux. Outputs
on Power Supply
board and ACM4/
ACM8 Access Power
Controllers’ outputs
Nominal DC
Output Voltage
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
Additional Fused
Outputs
ACM4/ACM8 Board
Input Fuse Rating
ACM8 Board
Output Fuse Rating
ACM4 Board
Output Fuse Rating
PDS8 Board
Input Fuse Rating
PDS8 Board
Output Fuse Rating
PD8UL Board
Output Fuse Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T1VK3F4 3.5 5A/ 250V 15A/
32V 24VDC @ 6A 20.17-
26.4
20.28-
26.4 8 – – – 10A/
32V
3A/
32V
T2VK7F8 4.5 6.3A/250V 15A/
32V 24VDC @ 9.7A 20.17-
26.4
20.28-
26.4 8 8 10A/
250V
2.5A/
250V 10A/
32V
3A/
32V
T3VK75F20 7.5
eFlow104NB
6.3A/ 250V 15A/
32V
24VDC @ 9.1A 20.17-
26.4
20.28-
26.4 20 8 10A/
250V
2.5A/
250V
3A/
32V 3.5A/
250V
eFlow102NB
5A/ 250V 12VDC @ 10A 9.7-
13.2
10.03-
13.2
Installation Instructions for Trove1, Trove2, Trove3:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and
screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws, level and
secure. Mark the position of the lower two/three holes. Remove the enclosure. Drill the lower holes and install the two/three fasteners.
Place the enclosure’s upper keyholes over the upper screws. Install the two/three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the
tamper switch bracket onto the edge of the enclosure approximately 2” from the right side
(Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the
appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount HID VertX® modules to backplane(s), refer to pages 3, 4, 5.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB,
eFlow104NB, eFlow102NB and corresponding Sub-Assembly Installation Guides for
ACM4, ACM8, PDS8, VR6 and PD8UL for further installation instructions.
Hardware:
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Nylon Spacer | 7/8” Pan Head Screw | Lock Nut
Trove HID VertX (Fuse) Kits Installation Guide - 3 -
T1VK3F4: Installation Instructions for HID VertX® Access Controllers
1. Fasten spacers (provided) onto metal pems configuration (A) of backplane (Fig. 2, pg. 3).
2. Mount HID VertX® modules to spacers utilizing 7/8” pan head screws (provided) (Fig. 2a, pg. 3).
3. Fasten backplane to Trove1 enclosure utilizing hardware (provided).
HID VertX® Access Controller Position Chart for the Following Models:
Sub-Assembly Pem Mounting
V100, V200, V300, V1000, V2000 A
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGER
AC DCAC1
EOL NO GND
SUPERVISED RESET
+AUX-
- BAT +- DC +
L G N
OFF - 24V
ON - 12V
ON
Altronix - eFlow6NB
+ INP1 --
DM1 +OFF
IN1
IN2
Out1
<1 off 2>
DM1 +
DM2 +
DM2 +
Common (--- )
Common (--- )
+ INP2 --
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
10
10
3
3
333333
Out2
<1 off 2>
Out3
<1 off 2>
Out4
<1 off 2>
Out5
<1 off 2>
Out6
<1 off 2>
Out7
<1 off 2>
Out8
<1 off 2>
Altronix - PDS8
Altronix VR6 is mounted under PDS8
HID VertX®
Module
A
HID VertX®
Module
A
Fig. 2
Pem
Spacer
HID VertX®
Access Controller
Backplane
Pan Head
Screw
Fig. 2a
- 4 - Trove HID VertX (Fuse) Kits Installation Guide
T2VK7F8: Installation Instructions for HID VertX® Access Controllers
1. Fasten spacers (provided) onto metal pems configuration (A) of backplane (Fig. 3, pg. 4).
2. Mount HID VertX® modules to spacers utilizing 7/8” pan head screws (provided) (Fig. 3a, pg. 4).
3. Fasten backplane to Trove2 enclosure utilizing hardware (provided).
HID VertX® Access Controller Position Chart for the Following Models:
Sub-Assembly Pem Mounting
V100, V200, V300, V1000, V2000 A
Altronix - eFlow104NB
– DC +– BAT +
L G N
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
+ INP1 --
DM1 +OFF
IN1
IN2
Out1
<1 off 2>
DM1 +
DM2 +
DM2 +
Common (--- )
Common (--- )
+ INP2 --
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
10
10
3
3
3333 33
Out2
<1 off 2>
Out3
<1 off 2>
Out4
<1 off 2>
Out5
<1 off 2>
Out6
<1 off 2>
Out7
<1 off 2>
Out8
<1 off 2>
Altronix VR6 is mounted under PDS8
A
HID VertX®
Module
A
HID VertX®
Module
A
HID VertX®
Module
A
HID VertX®
Module
Altronix - PDS8
Altronix - ACM8
Fig. 3
Pem
Spacer
HID VertX®
Access Controller
Backplane
Pan Head
Screw
Fig. 3a
Trove HID VertX (Fuse) Kits Installation Guide - 5 -
T3VK75F20: Installation Instructions for HID VertX® Access Controllers
1. Fasten spacers (provided) onto metal pems configuration (A) of backplane (Fig. 4, pg. 5).
2. Mount HID VertX® modules to spacers utilizing 7/8” pan head screws (provided) (Fig. 4a, pg. 5).
3. Fasten backplane to Trove3 enclosure utilizing hardware (provided).
HID VertX® Access Controller Position Chart for the Following Models:
Sub-Assembly Pem Mounting
V100, V200, V300, V1000, V2000 A
Altronix - eFlow104NB
– DC +– BAT +
L G N
--- BAT +
L G N
--- DC +
Altronix - eFlow102NB
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
TRG
TRIGGER
INPUT
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
1 2 3 4 5 6 7 8
D1
INPUT
P N
R1 LED
Altronix - PD8UL
AA
AA
AA
AA
AA
Altronix - ACM8
Altronix - ACM8
Altronix - ACM4
HID VertX®
Module
HID VertX®
Module
HID VertX®
Module
HID VertX®
Module
HID VertX®
Module
HID VertX®
Module
HID VertX®
Module
HID VertX®
Module
HID VertX®
Module
HID VertX®
Module
RSB2
Fig. 4
Pem
Spacer
HID VertX®
Access Controller
Backplane
Pan Head
Screw
Fig. 7a
- 6 - Trove HID VertX (Fuse) Kits Installation Guide
T1VK3F4 (Trove1) Enclosure Dimensions (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)
4.5” (114.3mm) 4.5” (114.3mm) 2.75”
(69.9mm)
1.115” (28.3mm)
1.36” (34.5mm)
1.25” (31.8mm) 1.25” (31.8mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
1.5” (38.1mm)
8.5” (215.9mm)6.5” (165.1mm)
4.5” (114.3mm)
13.0” (330.2mm)
0.6” (15.2mm)
14.5” (321.3mm)
1.45” (36.8mm)
7.25” (184.2mm)
1.95” (49.5mm)
1.1” (27.9mm)
0.6” (15.2mm)
0.57” (14.5mm)
18.0” (457.2mm)
1.25” (31.8mm)
Trove HID VertX (Fuse) Kits Installation Guide - 7 -
T2VK7F8 (Trove2) Enclosure Dimensions (H x W x D approximate):
27.25” x 21.75” x 6.5” (692.15mm x 546.1mm x 165.1mm)
6.75” (171.5mm)8.25” (209.5mm)
8.00” (203.2mm)
2.00” (50.8mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
1.25” (31.8mm)
6.25” (158.8mm) 19.80” (502.9mm)
1.00” (25.4mm)
27” (685.8mm)
1.5”
(38.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
3.5”(88.9mm) 3.5”(88.9mm)
21.50” (546.1mm)
5.25” (133.35mm) 5.25” (133.35mm)
6.25” (158.8mm)
1.25”
(31.8mm)
0.85” (21.6mm)
0.5625” (14.3mm)
2.415” (61.3mm)
0.685” (17.4mm)
1.77”
(45mm)
0.885” (22.5mm)
1.125” (28.3mm)
Knockouts
2.00” (50.8mm) 2.00” (50.8mm)
- 8 - Trove HID VertX (Fuse) Kits Installation Guide
T3VK75F20 (Trove3) Enclosure Dimensions (H x W x D approximate):
36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm)
G
G
2”
(50.8mm)
8.75” (222.3mm) 8.75” (222.3mm)
8.62” (219mm)
7.06” (179.3mm)
1.25” (31.8mm)
1.25” (31.8mm)
2.00” (50.8mm) 7.12” (222.3mm) 9.5” (241.3mm) 9.5” (241.3mm)
30.12” (768.1mm)
14.01” (355.9mm) 14.01” (355.9mm)
1.25” (31.8mm) 1.55” (39.4mm)
1.78” (45.2mm)
1.25” (31.8mm)
1.07”
(27.2mm)
1.10” (27.9mm)
2” (50.8mm)
10.75” (273.1mm)10.75” (273.1mm) 10.62” (269.8mm)
2.00” (50.8mm)10.75” (273.1mm)10.75” (273.1mm) 10.62” (269.8mm)
36.12” (917.5mm)
33.63” (854.2mm)
Altronix is not responsible for any typographical errors.
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IITrove HID VertX Kits J21U MEMBER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Altronix T3VK75F20 Installation guide

Type
Installation guide

Altronix T3VK75F20 is a fully assembled kit designed to integrate access control and power distribution for up to 20 doors. It includes a Trove3 enclosure with a TV3 backplane, one eFlow104NB and one eFlow102NB power supply/charger, two ACM8 and one ACM4 fused access power controllers, one PD8UL fused power distribution module, and one RSB2 rocker switch bracket with two switches. With its fused outputs and support for various HID VertX® modules, this kit offers reliable power and access control solutions for a wide range of applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI