Altronix T2AGK3F8 8 Door Kit Installation guide

Type
Installation guide

Altronix T2AGK3F8 8 Door Kit offers a seamless integration of power and access control for up to 8 doors. This pre-assembled kit includes an array of components, including a Trove2 enclosure, eFlow6NB power supply/charger, ACM8 fused access power controller, VR6 voltage regulator, and PDS8 dual input fused power distribution module. With fused outputs, it provides reliable power distribution for access control systems. The kit's compact design and pre-installed components simplify installation, saving time and effort.

Altronix T2AGK3F8 8 Door Kit offers a seamless integration of power and access control for up to 8 doors. This pre-assembled kit includes an array of components, including a Trove2 enclosure, eFlow6NB power supply/charger, ACM8 fused access power controller, VR6 voltage regulator, and PDS8 dual input fused power distribution module. With fused outputs, it provides reliable power distribution for access control systems. The kit's compact design and pre-installed components simplify installation, saving time and effort.

T2AGK3F8
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TAG2 Altronix/AMAG backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) ACM8 - Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
T2AGK7F12
12 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TAG2 Altronix/AMAG backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) ACM8 - Fused Access Power Controller
- One (1) ACM4 - Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
T2AGK75F12
12 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TAG2 Altronix/AMAG backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- One (1) ACM8 - Fused Access Power Controller
- One (1) ACM4 - Fused Access Power Controller
- One (1) PD4UL - Fused Power Distribution Module
Access & Power Integration
Altronix/AMAG M4000 Kits
Models Include:
Rev. TAGK_042319
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - Trove AMAG M4000 Kits Installation Guide
Overview:
Altronix Trove AMAG kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and
sub-assemblies. Kits accommodate up to three (3) AMAG M4000 modules for up to twelve (12) doors in a single enclosure.
Configuration Chart:
Altronix
Model
Number
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
120VAC 60Hz
Input Current (A)
Maximum Supply
Current for Main
and Aux. Outputs
on Power Supply
board and
ACM4/ACM8
Access Power
Controllers’
outputs
Nominal DC
Output Voltage
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
Additional Fused Outputs
ACM4 Board
Input Fuse Rating
ACM4 Board
Output Fuse Rating
ACM8 Board
Input Fuse Rating
ACM8 Board
Output Fuse Rating
PDS8 Board
Input Fuse Rating
PDS8 Board
Output Fuse Rating
PD4UL Board
Output Fuse Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T2AGK3F8 5A/250V 15A/
32V 3.5 24VDC @ 5.4A 20.17-
26.4
20.28-
26.4 8 8 10A/
250V
2.5A/
250V
10A/
32V
3A/
32V
T2AGK7F12 6.3A/250V 15A/
32V 4.5 24VDC @ 9.4A 20.17-
26.4
20.28-
26.4 12 8 10A/
250V
3A/
32V
10A/
250V
2.5A/
250V
10A/
32V
3A/
32V
T2AGK75F12
eFlow104NB
6.3A/ 250V 15A/
32V 7.5
24VDC @ 9.4A 20.17-
26.4
20.28-
26.4 12 4 10A/
250V
3A/
32V
10A/
250V
2.5A/
250V 3.5A/
250V
eFlow102NB
5A/ 250V 12VDC @ 10A 9.7-
13.2
10.03-
13.2
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in
the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure. Mark the
position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper
keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired
location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure
approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate
UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount AMAG M4000 modules to TAG2 backplane, refer to page 3-5.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB, eFlow102NB,
eFlow104NB, and corresponding Sub-Assembly Installation Guides for the following
models: ACM8, ACM4, PD4UL, PDS8 and VR6 for further installation instructions.
Hardware:
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Nylon Spacer | 5/16” Pan Head Screw | Lock Nut
Trove AMAG M4000 Kits Installation Guide - 3 -
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
Altronix - ACM8
AMAG - M4000
AMAG - M4000
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGER
AC DCAC1
EOLNOGND
SUPERVISED RESET
+AUX-
- BAT +- DC +
L G N
OFF - 24V
ON - 12V
ON
Altronix - eFlow6NB
+ INP1 --
PWR1 +
PWR1 +
OFF
IN1
IN2
PWR2 +PWR2 +
COM ---
COM ---
+ INP2 --
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
10
10
Altronix VR6 is mounted under PDS8
Altronix - PDS8
T2AGK3F8: Configuration of AMAG M4000 Modules:
1. Align the AMAG M4000 modules on the backplane to match the boards’ mounting holes with corresponding pems.
2. Fasten spacers (provided) onto metal pems (Fig. 2a, pg. 3).
3. Mount AMAG M4000 modules to spacers utilizing pan head screws (provided) (Fig. 2a, pg. 3).
4. Fasten TAG2 backplane to Trove2 enclosure utilizing hardware (provided).
Fig. 2
Pem
Spacer
AMAG M4000
Module
Backplane
Pan Head
Screw
Fig. 2a
- 4 - Trove AMAG M4000 Kits Installation Guide
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
Altronix - ACM8
TRG
TRIGGER
INPUT
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix
ACM4
+ INP1 --
PWR1 +
PWR1 +
OFF
IN1
IN2
Out1
<1 off 2>
PWR2 +PWR2 +
COM ---
COM ---
+ INP2 --
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
10
10
3
3
3333 33
Out2
<1 off 2>
Out3
<1 off 2>
Out4
<1 off 2>
Out5
<1 off 2>
Out6
<1 off 2>
Out7
<1 off 2>
Out8
<1 off 2>
Altronix - PDS8
VR6 is mounted
under PDS8
AMAG - M4000
AMAG - M4000
AMAG - M4000
Altronix - eFlow104NB
– DC +– BAT +
L G N
T2AGK7F12: Configuration of AMAG M4000 Modules:
1. Align the AMAG M4000 modules on the backplane to match the boards’ mounting holes with corresponding pems.
2. Fasten spacers (provided) onto metal pems (Fig. 3a, pg. 4).
3. Mount AMAG M4000 modules to spacers utilizing pan head screws (provided) (Fig. 3a, pg. 4).
4. Fasten TAG2 backplane to Trove2 enclosure utilizing hardware (provided).
Fig. 3
Pem
Spacer
AMAG M4000
Module
Backplane
Pan Head
Screw
Fig. 3a
Trove AMAG M4000 Kits Installation Guide - 5 -
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
Altronix - ACM8
TRG
TRIGGER
INPUT
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix
ACM4
Altronix - eFlow104NB
– DC +– BAT +
L G N
Altronix - PD4UL
F1 F2 F3 F4
1P 1N 2P 2N 3P 3N 4P 4N
P N
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGER EOL
SUPERVISED
AC DCAC1
NO GND
RESET + AUX -
--- BAT +
L G N
1 min enable
2 hr disable
--- DC +
Altronix - eFlow102NB
AMAG - M4000
AMAG - M4000
AMAG - M4000
T2AGK75F12: Configuration of AMAG M4000 Modules:
1. Align the AMAG M4000 modules on the backplane to match the boards’ mounting holes with corresponding pems.
2. Fasten spacers (provided) onto metal pems (Fig. 4a, pg. 5).
3. Mount AMAG M4000 modules to spacers utilizing pan head screws (provided) (Fig. 4a, pg. 5).
4. Fasten TAG2 backplane to Trove2 enclosure utilizing hardware (provided).
Fig. 4
Pem
Spacer
AMAG M4000
Module
Backplane
Pan Head
Screw
Fig. 4a
- 6 - Trove AMAG M4000 Kits Installation Guide
Notes:
Trove AMAG M4000 Kits Installation Guide - 7 -
eFlow Power Supply/Chargers can be Controlled and Monitored while
Reporting Power/Diagnostics from Anywhere over the Network...
LINQ2 Mounts Inside any Trove Enclosure
LINQ2 - Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep systems up
and running at optimal levels. It facilitates fast and easy installation and set-up, minimizes system downtime,
and eliminates unnecessary service calls, which helps reduce Total Cost of Ownership (TCO) - as well as creat-
ing a new source of Recurring Monthly Revenue (RMR).
LINQ2
Features:
- UL Listed in the U.S. and Canada.
- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change,
output state change and unit temperature.
- Access control and user managment: Restrict read/write, Restrict users to specific resources
- Two (2) integral network controlled Form “C” Relays.
- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
- Email and Windows Dashboard notifications
- Event log tracks history.
- Secure Socket Layer (SSL).
- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.
LINQ2 Module
Altronix eFlow
Power Supply
Network Connection:
Installation, Programming
and Monitoring
- 8 - Trove AMAG M4000 Kits Installation Guide
Altronix is not responsible for any typographical errors.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IITrove AMAG M4000 Kits I17U MEMBER
Enclosure Dimensions (H x W x D approximate):
27.25” x 21.5” x 6.5” (692.15mm x 546.1mm x 165.1mm)
6.75” (171.5mm)8.25” (209.5mm)
8.00” (203.2mm)
2.00” (50.8mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
1.25” (31.8mm)
6.25” (158.8mm) 19.80” (502.9mm)
1.00” (25.4mm)
27” (685.8mm)
1.5”
(38.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
3.5”(88.9mm) 3.5”(88.9mm)
21.50” (546.1mm)
5.25” (133.35mm) 5.25” (133.35mm)
6.25” (158.8mm)
1.25”
(31.8mm)
0.85” (21.6mm)
0.5625” (14.3mm)
2.415” (61.3mm)
0.685” (17.4mm)
1.77”
(45mm)
0.885” (22.5mm)
1.125” (28.3mm)
Knockouts
2.00” (50.8mm) 2.00” (50.8mm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Altronix T2AGK3F8 8 Door Kit Installation guide

Type
Installation guide

Altronix T2AGK3F8 8 Door Kit offers a seamless integration of power and access control for up to 8 doors. This pre-assembled kit includes an array of components, including a Trove2 enclosure, eFlow6NB power supply/charger, ACM8 fused access power controller, VR6 voltage regulator, and PDS8 dual input fused power distribution module. With fused outputs, it provides reliable power distribution for access control systems. The kit's compact design and pre-installed components simplify installation, saving time and effort.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI