Altronix Trove T2SSK7F8 Installation guide

Type
Installation guide

Altronix Trove T2SSK7F8 is a pre-assembled kit designed for access control and power distribution in security systems. It includes an enclosure, power supply, access power controller, voltage regulator, and power distribution modules, allowing for the integration of up to eight doors. The kit is compatible with Lenel-S2 (S2 Security Platform) S2-INST Installation Kit for S2 Network Node. It features fused outputs and provides a nominal DC output voltage of 12VDC @ 10A or 24VDC @ 9.4A.

Altronix Trove T2SSK7F8 is a pre-assembled kit designed for access control and power distribution in security systems. It includes an enclosure, power supply, access power controller, voltage regulator, and power distribution modules, allowing for the integration of up to eight doors. The kit is compatible with Lenel-S2 (S2 Security Platform) S2-INST Installation Kit for S2 Network Node. It features fused outputs and provides a nominal DC output voltage of 12VDC @ 10A or 24VDC @ 9.4A.

T2SSK7F8
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TSS2 Altronix/Lenel-S2 (S2 Security Platform) backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) ACM8 - Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
- One (1) RSB1* - Rocker Switch Bracket with One (1) Rocker Switch (Not evaluated by UL)
T2SSK75F14
14 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TSS2 Altronix/Lenel-S2 (S2 Security Platform) backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- Two (2) ACM8 - Fused Access Power Controllers
- Two (2) PD8UL - Fused Power Distribution Module
- One (1) RSB2* - Rocker Switch Bracket with Two (2) Rocker Switches (Not evaluated by UL)
Access & Power Integration
Rev. TSSK2_051520
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - Trove2 S2 (Fuse) Kits
Overview:
Altronix T2SSK7F8 and T2SSK75F14 Trove S2 kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed
Altronix power supply/chargers and sub-assemblies. Both kits accommodate Lenel-S2 (S2 Security Platform) S2-INST Installation Kit for
S2 Network Node for up to eight (8) (T2SSK7F8) or fourteen (14) (T2SSK75F14) doors in a single enclosure.
Configuration Chart:
Altronix
Model
Number
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
120VAC 60Hz
Input Current (A)
Maximum Supply
Current for Main and
Aux. Outputs on
Power Supply board
and ACM8CB Access
Power Controllers’
outputs
Nominal DC
Output Voltage
Fail-Safe/Fail-Secure
Outputs
Additional Fused
Outputs
ACM8 Board
Input Fuse Rating
ACM8 Board
Output Fuse Rating
PDS8 Board
Input Fuse Rating
PDS8 Board
Output PTC Rating
PD8UL Board
Output Fuse Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T2SSK7F8
6.3A/250V
15A/
32V
4.5 24VDC @ 9.7A
20.17-
26.4
20.28-
26.4
8 8
10A/
250V
3.5A/
250V
10A/
32V
3A/
32V
T2SSK75F14
eFlow104NB
6.3A/ 250V
15A/
32V
7.5
24VDC @ 9.4A
20.17-
26.4
20.28-
26.4
16 16
10A/
250V
3.5A/
250V
3.5A/
250V
eFlow102NB
5A/ 250V
12VDC @ 10A
9.7-
13.2
10.03-
13.2
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and
screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two/three upper screws;
level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three
fasteners. Place the enclosure’s upper keyholes over the two/three upper screws. Install the three lower screws and make sure to
tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired
location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure
approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the
Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount S2-INST Installation Kit to backplane, refer to pages 3, 4.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow102NB,
eFlow104NB and corresponding Sub-Assembly Installation Guides for ACM8,
PDS8, VR6 and PD8UL for further installation instructions.
Hardware:
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Lock Nut
Trove2 S2 (Fuse) Kits - 3 -
T2SSK7F8: Access Controller Position Chart for the S2-INST Installation Kit:
1. Align S2-INST mounting holes with pems on TSS2 (Fig. 2, pg. 3).
2. Attach S2-INST to backplane with lock nuts (provided) (Fig. 2a, pg. 3).
3. Mount backplane to enclosure with hardware.
4. Fasten TSS2 backplane to Trove2 enclosure utilizing hardware (provided).
Fig. 2
Pem
Lock nut
S2-INST Bracket
Backplane
Altronix - eFlow104NB
– DC +– BAT +
L G N
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4
5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
Altronix - ACM8
+ INP1
--
DM1 +
OFF
IN1
IN2
Out1
<
1 off 2
>
DM1 +
DM2 +
DM2 +
Common (--- )
Common (--- )
+ INP2
--
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
10
10
3
3
3333 33
Out2
<
1 off 2
>
Out3
<
1 off 2
>
Out4
<
1 off 2
>
Out5
<
1 off 2
>
Out6
<
1 off 2
>
Out7
<
1 off 2
>
Out8
<
1 off 2
>
Altronix - PDS8
Altronix VR6 mounted under PDS8
S2-INST
Installation Kit for
S2 Network Node
RSB1
Fig. 2a
- 4 - Trove2 S2 (Fuse) Kits
T2SSK75F14: Access Controller Position Chart for the S2-INST Installation Kit:
1. Align S2-INST mounting holes with pems on TSS2 (Fig. 3, pg. 4).
2. Attach S2-INST to backplane with lock nuts (provided) (Fig. 3a, pg. 4).
3. Mount backplane to enclosure with hardware.
4. Fasten TSS2 backplane to Trove2 enclosure utilizing hardware (provided).
Fig. 3
S2-INST
Installation Kit for
S2 Network Node
Altronix - eFlow104NB
– DC +
– BAT +
L G N
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4
5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
Altronix - ACM8
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4
5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-
NO C NC
FACP INTERFACE
Power Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
TRG
FACP
1 2 3 4
1 2 3 4
ON
ON
1 2 3 4
1 2 3 4
ON
ON
Altronix - ACM8
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
1 2 3 4 5 6 7 8
D1
INPUT
P N
R1
LED
Altronix - PD8UL
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGER EOL
SUPERVISED
AC DCAC1
NO GND
RESET
+ AUX -
--- BAT +
L G N
1 min enable
2 hr disable
--- DC +
Altronix - eFlow102NB
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
1 2 3 4 5 6 7 8
D1
INPUT
P N
R1
LED
Altronix - PD8UL
RSB2
Fig. 3a
Pem
Lock nut
S2-INST Bracket
Backplane
Trove2 S2 (Fuse) Kits - 5 -
Notes:
- 6 - Trove2 S2 (Fuse) Kits
Notes:
Trove2 S2 (Fuse) Kits - 7 -
eFlow Power Supply/Chargers can be Controlled and Monitored while
Reporting Power/Diagnostics from Anywhere over the Network...
LINQ2 Mounts Inside any Trove Enclosure
LINQ2 - Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep
systems up and running at optimal levels. It facilitates fast and easy installation and set-up, mini-
mizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost
of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR).
LINQ2
Features:
- UL Listed in the U.S. and Canada.
- Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
- Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change,
output state change and unit temperature.
- Access control and user managment: Restrict read/write, Restrict users to specific resources
- Two (2) integral network controlled Form “C” Relays.
- Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
- Email and Windows Dashboard notifications
- Event log tracks history.
- Secure Socket Layer (SSL).
- Programmable via USB or web browser - includes operating software and 6 ft. USB cable.
LINQ2 Module
Altronix eFlow
Power Supply
Network Connection:
Installation, Programming
and Monitoring
- 8 - Trove2 S2 (Fuse) Kits
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.
IITrove SS Kits E15T
MEMBER
Enclosure Dimensions (H x W x D):
27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)
6.75” (171.5mm)8.25” (209.5mm)
8.00” (203.2mm)
2.00” (50.8mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
1.25” (31.8mm)
6.25” (158.8mm)
19.80” (502.9mm)
1.00” (25.4mm)
27” (685.8mm)
1.5”
(38.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
3.5”(88.9mm) 3.5”(88.9mm)
21.50” (546.1mm)
5.25” (133.35mm)
5.25” (133.35mm)
6.25” (158.8mm)
1.25”
(31.8mm)
0.85” (21.6mm)
0.5625” (14.3mm)
2.415” (61.3mm)
0.685” (17.4mm)
1.77”
(45mm)
0.885” (22.5mm)
1.125” (28.3mm)
Knockouts
2.00” (50.8mm)
2.00” (50.8mm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Altronix Trove T2SSK7F8 Installation guide

Type
Installation guide

Altronix Trove T2SSK7F8 is a pre-assembled kit designed for access control and power distribution in security systems. It includes an enclosure, power supply, access power controller, voltage regulator, and power distribution modules, allowing for the integration of up to eight doors. The kit is compatible with Lenel-S2 (S2 Security Platform) S2-INST Installation Kit for S2 Network Node. It features fused outputs and provides a nominal DC output voltage of 12VDC @ 10A or 24VDC @ 9.4A.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI