Nortel Networks CTA 500dm User manual

Category
Telephones
Type
User manual
P0873832 Issue 05 CTA 500
dm
On Line Guide
CTA 500
dm
The CTA 500 digital modem (CTA 500
dm
) is an optional device
used with the Norstar Integrated Communication System (ICS).
With ICS software, using release 2.0 or higher, the CTA 500
dm
provides integrated desktop solutions for digital networking
applications. With optional Norstar Telephony API Service Provider
(TAPI SP), the CTA 500
dm
also supports Computer Telephony
Integration (CTI) services required for today's ofÞce environment.
With the CTA 500
dm
you can access remote computers on networks
including the Internet. You can also telecommute over a digital
telephone network and access the CTA 500
dm
in your ofÞce. The
CTA 500
dm
allows you to access high-speed network features in
your ofÞce from your home telephone.
The CTA 500
dm
in the Digital Network
ISDN
CTA 500dm
CTA 500dm
Norstar telephone
Computer terminal
Internet
Service Provider
Digital line
Digital line
LAN
Norstar
ICS
Norstar
ICS
Computer terminal Computer terminal
2
CTA 500dm
CTA 500
dm
On Line Guide P0873832 Issue 05
The CTA 500
dm
serves as a digital modem and terminal adapter
(TA). A terminal adapter is a device that allows non-ISDN devices
to work with ISDN. It provides reliable high speed end-to-end
digital connectivity between your computer and a remote data server
using the ICS and the public switched telephone network (PSTN) or
Integrated Services Digital Network (ISDN). The CTA 500
dm
supports Point-to-Point Protocol (PPP) and Multilink PPP (MP),
which are widely supported by Internet service providers (ISPs) for
Internet access and corporate data communication networks
(Intranets) for remote LAN access. PPP and MP are supported as
built-in features of Windows95.
You can also connect a Norstar telephone to the CTA 500
dm
to
access Norstar voice services. You can use the same telephone line
to simultaneously carry on a conversation while your computer is
connected to the Internet or remote LAN with no loss of ICS
features. The CTA 500
dm
connects to the ICS using standard
telephone cabling.
MP works with intelligent bandwidth management software in the
ICS to provide dynamic bandwidth allocation accessible at your
desktop. Norstar station interfaces support two channels that are
ßexibly allocated to transmit data, voice, or both. When the attached
Norstar telephone is not in use, all bandwidth is allocated for data
trafÞc (up to 128 kbit/s). However, if you want to use the phone to
answer an incoming call, or place a call using the free line or the
intercom, one channel is automatically allocated for the
conversation and the data connection continues at 64 kbit/s. When
you hang up the telephone, the second channel is automatically
reallocated to the data connection.
Using a CTA 500
dm
compliant Norstar TAPI Service Provider, the
CTA 500
dm
allows simultaneous PPP/MP data connections and
TAPI computer telephony integration (CTI) applications on your
PC.
In addition, some of the ICS resources normally used for voice
applications, such as network access lines and calling line features,
can be used for data trafÞc. Network access lines can be shared
between CTA 500
dm
s and other trafÞc within the system. Features
such as call logging, call restriction, and routing based on time of
day can be applied to data trafÞc for facility utilization and
management.
CTA 500dm 3
P0873832 Issue 05 CTA 500
dm
On Line Guide
Any PC equipped with Windows95, Internet application software,
and a 16550 UART (115.2 kbit/s capability) can use the
CTA 500
dm
.
Applications
The CTA 500
dm
can be used for any application that requires
dial-up capability and uses Point-to-Point Protocol.
These applications include
¥ Internet access
¥ remote LAN access
¥ high-speed modem replacement
¥ CTI based applications when Norstar TAPI SP is added
¥ data transmission at up to 64 kbit/s on either channel of an ISDN
link or 56 kbit/s on a T1 trunk
¥ supports Multilink PPP to enable the dial-up connections to use
two channels
Internet access
The CTA 500
dm
allows Norstar customers using digital network
interfaces on the Norstar ICS to access Internet service providers
(ISPs). You can connect an ISP through the public switched digital
network (PSDN) using regular dial-up methods.
Dial-Up Networking
You can use the CTA 500
dm
for remote LAN access applications
when PPP is used to connect to a remote LAN.
Data-to-data transfers
The CTA 500
dm
can be used to establish a connection with an ISDN
Terminal Adapter (PPP or MP must be supported) or another
CTA 500
dm
for Þle transfer. You can connect two computers to the
same ICS through their own CTA 500
dm
units, or connect them
through the network. Using the CTA 500
dm
connection allows
analog modems to be replaced with high-speed digital connections.
The CTA 500
dm
does not support connection to analog or 56k
modems.
Computer Telephony Integration (CTI)
With a compliant Norstar TAPI SP, the CTA 500
dm
allows
simultaneous sessions of PPP/MP and CTI based applications to run
on PCs.
4
CTA 500dm
CTA 500
dm
On Line Guide P0873832 Issue 05
CTA 500
dm
feature summary
¥ digital networking using PPP/MP
¥ simpliÞed installation and conÞguration using installation wizard
¥ high-speed network rate (56, 64, 112, or 128 kbit/s)
¥ high-speed serial port support (maximum 115,200 baud)
¥ integrated desktop solutions (Norstar set, data transfer, and CTI)
¥ bonding of two 56/64 kbit/s channels using MP
¥ dynamic bandwidth allocation between voice and data sessions
¥ data transfer using 3.1 kHz audio call type in ISDN
¥ support of Password Authentication Protocol (PAP) and with
PPP connections, Challenge Handshake Authentication Protocol
(CHAP)
¥ Hayes AT command dialing and conÞguration
¥ incoming call screening using calling line identiÞcation for
security
¥ in-Þeld software upgrade for feature enhancement
¥ ICS call management feature support (for example, dialing
restrictions, station message detail recording)
¥ ICS default conÞguration for simpliÞed installation
About this document
¥ The First-time setup section has initial installation information.
¥ The Installation and setup section has information on installing
the CTA 500
dm
and conÞguring your PC and ICS.
¥ The ConÞguration section has information on conÞguring the
CTA 500
dm
and Norstar TAPI Service Provider.
¥ The Installing Norstar TAPI SP section has information on
setting up Norstar TAPI Service Provider
¥ The Resource sharing section shows how to conÞgure PCs
equipped with CTA 500
dm
to act as Dial-Up Servers.
¥ The AT commands section details the commands used to
conÞgure the CTA 500
dm
.
¥ The Troubleshooting section assists you if you experience
problems when using the CTA 500
dm
.
¥ The Appendix provides important electromagnetic and radio
frequency information.
P0873832 Issue 05 CTA 500
dm
On Line Guide
First-time setup
This section guides you through the initial installation and setup of
the CTA 500
dm
. Installation is carried out from the Personal
Productivity Suite CD-ROM. Use the steps listed below to complete
the installation.
1. Make the physical connections to the CTA 500
dm
.
See
Installation and setup
2. ConÞgure the ICS for the CTA 500
dm
.
See
Setting up the ICS
3. ConÞgure the Com port on the PC for the CTA 500
dm
.
See
ConÞguring the PC serial port
4. Install the CTA 500dm and if required, the Norstar TAPI Service
Provider software.
See
Installing CTA 500dm and Norstar TAPI Service Provider
software
.
6
First-time setup
CTA 500
dm
On Line Guide P0873832 Issue 05
P0873832 Issue 05 CTA 500
dm
On Line Guide
Installation and setup
You can place the CTA 500
dm
on the desk or mount it on the wall.
Refer to ÒWall mounting the CTA 500dmÓ on page 8 of this
document for the procedure.
The CTA 500
dm
has four jacks that are used to connect a Norstar
telephone, an ICS, a computer, and the power supply.
¥ connect a Meridian Norstar telephone to the Terminal jack (use
the telephone cable included with the Norstar set)
¥ connect the ICS wall plug to the Line jack (use the included
6-way modular socket). Depending on the ICS software release,
restrictions may apply on the maximum number of ports and the
physical ports to which the CTA 500
dm
can be connected. Refer
to the wiring information in
ICS
Installation Guide
for more
information.
¥ connect the DB-25 connector to the serial port on the PC (use the
included RS-232 cable)
¥ connect the supplied 9 V dc, 0.6 A power adapter to the dc port
(plug the other end of the adapter into a standard three-prong ac
outlet)
Tele-
phone
KSU
Port
DB-25
9 V dc
Power
LED
8
Installation and setup
CTA 500
dm
On Line Guide P0873832 Issue 05
Wall mounting the CTA 500
dm
1. Tape the paper template, supplied with the product, to the wall
allowing 12.5 cm (6 in.) clearance for connections to the
CTA 500
dm
.
2. Insert the screws as indicated on the template. Use 4 mm (#8)
screws, leaving 6 mm (0.5 in.) of the screw exposed for
mounting.
3. Remove the template.
CTA 500
dm
bottom view
4. Mount the CTA 500
dm
onto the screws making sure to orient the
connector ports so they are at the top of the CTA 500
dm
.
5. Route the cables away from the CTA 500
dm
to avoid potential
electromagnetic interference.
CAUTION!
Shock hazard
For protection from shock hazards, the CTA 500
dm
must
receive power from an Approved Class 2 power pack
equipped with a straight plug, center positive connector
with a rating of 9 V dc at 0.6 A.
Note:
The approved power pack must be either CSA or
C-UL certified in Canada, and either UL or NRTL listed in
the United States.
Installation and setup 9
P0873832 Issue 05 CTA 500
dm
On Line Guide
Setting up the ICS
Program the ICS for the CTA 500dm the same way that you program
the ICS for a Norstar set. You can program line access, line pool
codes and restrictions to apply to outgoing calls. The CTA 500dm
must be assigned to a digital line or to a digital line pool. Refer to the
ÒTerminals and sets programmingÓ section of your Installer Guide
for more information.
The CTA 500dm is a B2 channel device and must be assigned a B2
channel DN. The following table shows the default directory
number (DN) that is assigned to the CTA 500dm based on the
physical set port that connects the CTA 500dm to the ICS.
You can change the DN that is assigned to the CTA 500dm in the
same way that you change a DN for a Norstar telephone. Refer to
ICS Installation Guide for more information.
Note: If you use automatic telephone relocation (set relocation) to
change the port used by a CTA 500dm, you must power down
the CTA 500dm before changing the connections. If the
CTA 500dm is not powered down, programming information
will be lost. See ICS Installer Guide for more information
about set relocation.
Compact ICS Modular ICS
ICS Port Default DN ICS Port Default DN
101 80 123 697
102 81 124 698
103 82 125 699
104 83 126 700
105 84 127 701
106 85 128 702
107 86 129 703
108 87 130 704
109 88 131 705
110 89 132 706
10 Installation and setup
CTA 500
dm
On Line Guide P0873832 Issue 05
Setting up the PC
Each PC operating system requires a different set up.
Note: Installation using another vendorÕs protocol stack packages
will differ. See the AT commands section of this document for
information on conÞguring advanced operations on the
CTA 500dm from your PC. See the Appendix for a list of the
DB-25 pins used by the CTA 500dm.
P0873832 Issue 05 CTA 500
dm
On Line Guide
Configuration
Some operations that you can perform with the CTA 500dm include
the following:
¥ ConÞguring the PC serial port
¥ Installing CTA 500dm and Norstar TAPI Service Provider
software
Note: Before you begin conÞguration, connect the ICS and the PC
as described in the ÒInstallation and setupÓ section and power
up the CTA 500dm.
12 Configuration
CTA 500
dm
On Line Guide P0873832 Issue 05
Configuring the PC serial port
¥ Verify the port baud rate is set to 115,200 (default) using the
Serial Interface Rate command.
¥ Set the character length, using the Set Data Bits command and
parity, using the Set Parity command. The default is 8 bits with
no parity (recommended).
¥ Set the ßow control using the Flow Control command. The
default is hardware (recommended).
Installing CTA 500
dm
and Norstar TAPI Service Provider software
1. From the Norstar Personal Productivity Suite main screen, select
the Language, and then the Installation option.
2. After accepting the licensing terms and reading the TAPI
requirements (if displayed), select the Install option.
3. Select the CTA 500dm from the right hand side of the dialog box
(under the Drivers section).
4. On the left hand side of the dialog box, select the components
you wish to install:
Drivers Ñ the required drivers and conÞguration utility for the
CTA 500dm
Toolkits Ñ CTE, Norstar TAPI Service Provider (TSP)
Applications
5. Follow the on-screen instructions to select automatic
conÞguration, and to select the proper communications port.
6. Choose the appropriate settings for your installation.
Configuration 13
P0873832 Issue 05 CTA 500
dm
On Line Guide
7. Click Next. A message displays the name assigned to the
installation. If you need more than one init string for the CTA
500dm, refer to ÒAdding multiple CTA 500dm conÞgurationsÓ
on page 16 for the procedure.
8. Click OK.
9. Click Yes to automatically setup Internet access through your
CTA 500dm.
10. Click Next when you see the message indicating that all network
components required are present.
11. Click Yes to automatically setup a connection to your Internet
service provider.
12. Select Norstar CTA 500dm.
13. Click Next.
14. Select one of the Internet service providers from the list or click
None of the above.
15. When the Connect To window displays, enter your user name
and password.
16. Click Next.
14 Configuration
CTA 500
dm
On Line Guide P0873832 Issue 05
17. When the Connection Settings dialog box displays, enter the
Internet service provider telephone number.
18. Click Next.
19. The installation is complete and you need to restart your
computer before using the CTA 500dm.
20. Click the Finish button.
Configuring the CTA 500
dm
(if not configured during installation)
1. From the Windows Start button, navigate to Programs, Norstar
CTA 500dm, CTA 500dm ConÞguration.
2. The CTA 500dm ConÞguration Options dialog box is displayed.
3. Choose the appropriate settings for your installation.
Configuration 15
P0873832 Issue 05 CTA 500
dm
On Line Guide
Configure CTA 500
dm
to access PP/MP data calls
1. Double-click on the My Computer icon on your desktop.
2. Double-click Dial-Up Networking icon.
3. Double-click Make New Connection icon.
4. When the Make New Connection window displays, choose
Norstar CTA 500dm modem from the pull-down menu.
5. Click the ConÞgure button.
6. Click the Connection tab.
7. Click the Advanced button.
8. In the Advanced Connection Settings window, type AT&D1 in
the Extra settings box.
16 Configuration
CTA 500
dm
On Line Guide P0873832 Issue 05
9. Click OK.
10. Close all windows.
Adding multiple CTA 500
dm
configurations
1. Click the Start button.
2. Choose Programs from the menu.
3. Choose CTA 500dm from the sub-menu.
4. Choose CTA 500dm conÞgurations.
5. Select the ConÞguration tab.
6. Choose settings for the required conÞguration.
7. Click OK.
You now have another CTA 500dm conÞguration with different
settings than the Þrst one. Make sure that you note the speciÞc
settings when you create the connection icons.
Configuration 17
P0873832 Issue 05 CTA 500
dm
On Line Guide
Upgrading the CTA 500
dm
software
CTA 500dm software upgrades are periodically made available
through your Norstar distributor. Contact your Norstar distributor
for details about receiving software upgrades.
Use the CTA 500dm conÞguration utility to display current settings
or to update software.
1. Click the Browse button.
2. When Þle information displays, click Transmit.
3. Advanced connection settings can be deÞned using the setup
wizard or the Enter Download State command.
Uninstalling the CTA 500
dm
1. Open the Control Panel.
2. Open Modems.
3. Select the CTA 500dm conÞguration that you want to uninstall.
4. Click Remove.
Note: You must select another modem for any remaining
Dial-Up Networking connections.
If you need to completely uninstall the CTA 500dm, remove all
CTA 500dm conÞgurations and delete the CTA 500dm directory and
program group.
18 Configuration
CTA 500
dm
On Line Guide P0873832 Issue 05
P0873832 Issue 05 CTA 500
dm
On Line Guide
Installing Norstar TAPI SP
To use a CTA 500dm for TAPI applications, Norstar TSP must be
installed. It can be installed at the same time as the CTA 500dm
software via the Personal Productivity Suite (PPS) installation
procedure, or it can be installed later from the PPS CD.
Note: The current CTA 500dm conÞguration does not support
dynamic bandwidth allocation if you donÕt have access to a
line pool with more than two ISDN lines. When you are
making an MP data call and want to make a voice call at the
same time, lift the telephone handset in order to make a
channel available for the call.
Configure TAPI dialing properties
If you use an access code to get an external line or get a private
network line to make a long distance call (for example, dial 9 before
dialing an external number or dial 6 before dialing a long distance
number), you need to conÞgure the Norstar set attached to the CTA
500dm.
1. Click the Start button and move the cursor to Settings.
2. Choose Control Panel from the sub-menu.
3. When the Control Panel window displays, double-click the
Telephony icon.
4. When the Telephony Properties window displays, click the
Dialing Properties button.
20 Installing Norstar TAPI SP
CTA 500
dm
On Line Guide P0873832 Issue 05
5. In the Dialing properties window, locate To access an outside
line, first dial: and enter x for local (where x represent s the
access code) and when applicable, y for long distance (where y
represents the code to access a private network).
6. Click OK.
7. Close all windows.
Installing Personal Call Manager
The Personal Call Manager (PCM) application is supplied on the
Norstar Personal Productivity Suite (PPS) CD-ROM.
1. From the PPS main screen, select the Language, and then the
Installation option.
2. After accepting the licensing terms and reading the TAPI
requirements (if displayed), select the Install option.
3. On the left hand side of the dialog box, select Applications and
then select PCM from the right hand side of the dialog box.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

Nortel Networks CTA 500dm User manual

Category
Telephones
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI