Nortel Networks DS30 User manual

Category
Network media converters
Type
User manual

Nortel Networks DS30 is a device that multiplexes up to eight Nortel Norstar TCM Loops (up to 16 voice paths) into one DS-30 fiber optic line. Each TCM Loop may include up to two active voice/data paths as well as a control signaling path. It's compatible with ACCESS 2.6 ver. 6.52 and higher within application products running on the NAM II platform. The device has a mean time before failure (MTBF) target of greater than 20 years.

Nortel Networks DS30 is a device that multiplexes up to eight Nortel Norstar TCM Loops (up to 16 voice paths) into one DS-30 fiber optic line. Each TCM Loop may include up to two active voice/data paths as well as a control signaling path. It's compatible with ACCESS 2.6 ver. 6.52 and higher within application products running on the NAM II platform. The device has a mean time before failure (MTBF) target of greater than 20 years.

•••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••
DS30/Station Port Adapter
Installation Guide
878745-Prt Adpter F Cov Page 1 Thursday, December 4, 1997 10:50 AM
1
DS30/Station Port Adapter Installation Guide
DS30/STATION PORT ADAPTER
REGULATORY APPROVAL
Table 1. Regulatory Approvals
TYPE COUNTRY SPECIFICATION PROCEDURE
Radiated Canada ICES-003/CISPR22 Class B ANSI C63.4
Emissions US FCC Part 15/CISPR22 Class B ANSI C63.4
UK EN55022 ANSI C63.4
Conducted Canada ICES-003/CISPR22 Class B ANSI C63.4
Emissions United States FCC Part 15/CISPR22 Class B ANSI C63.4
UK EN 55022 ANSI C63.4
EN50082-1
Safety Canada CSA C22.2 No. 950-95 (CUL)
US UL 1950 edition 3
UK EN 60950
International IEC 950 edition 2
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. The limits are designed
to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy, and if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
NOTE
WARNING
Use only UL CSA/cUL approved Class 2 Wall Mount
Power Supply with a rated output of 12VAC.
2
Installation Guide DS30/Station Port Adapter
1 4 7
2 5 8
3 6
POWER
DS - 30
FIBER OPTIC
KSU 5 - 8
KSU 1 - 4
FIBER
LINE
Figure 1. DS-30/Station Port Adapter
TCM
Loops
1-4
TCM
Loops
5-8
Fiber Line Status LED
TCM
Loop
Status
LEDs (8)
CONNECTOR RJ-45 Jacks Two RJ-45 jacks each accepting up to
INTERFACES four TCM Loops
DS-30 Fiber One female DS-30
Connector fiber optic connector pair
Power One barrel jack for internal
Connector power supply to wall mounted 12 VAC
power source
SIZE Approx. 9.75” (248 mm) x 5.06” (129 mm) x 1.22”
(36mm)
WEIGHT Estimated 20 ounces (567 grams) includes bezel and
PCB but not wall-mounted power supply
POWER
Country Output/Input Rating
North America 12VAC @ 600mA/110VAC
United Kingdom 12VAC @ 600mA/240VAC
Australia 12VAC @ 600mA/240VAC
RELIABILITY Mean time before failure (MTBF) target is greater than
20 years using Mil-Std-217F method TBD reliability
calculations.
FUNCTIONAL Multiplexes up to eight Nortel Norstar TCM Loops
DESCRIPTION (up to 16 voice paths) into one DS-30 fiber optic
line. Each TCM Loop may include up to two active
voice/data paths as well as a control signaling path.
PRODUCT DESCRIPTION
Table 2. Product Description
RJ-45 Connectors
AC Power
Connector
DS30 Fiber
Connector
3
DS30/Station Port Adapter Installation Guide
INSTALLATION
1. Connect the TCM Loops from the KSU to a male RJ-45 connector
using the wiring scheme in Figure 2 below. Connect up to 8 TCM
Loops with TCM Loops 1 to 4 in RJ-45 connector 1 and TCM Loops 5
to 8 in RJ-45 connector 2.
2. Insert KSU RJ-45 male connector(s) into the appropriate female RJ-45
connector in the adapter.
3. Insert DS-30 fiber connector of fiber line from Applications Module
into DS-30 Fiber Connector of adapter.
4. Plug power cord into AC Power Connector.
5. Plug the adapter power into an AC wall outlet.
WARNING: Use only UL
CSA/cUL approved Class 2 Wall Mount Power Supply with a rated
output of 12VAC.
Figure 2. TCM Loop RJ-45 Pinout Connections
Female RJ-45
JP1
TCM Loops 1-4
4- 3- 2- 1- 1+ 2+ 3+ 4+
8 7 6 5 4 3 2 1
Loops 1-4
Pins 1-8
To Norstar KSU
To Adapter
RJ-45
Connector
Female RJ-45
JP1
TCM Loops 5-8
8- 7- 6- 5- 5+ 6+ 7+ 8+
8 7 6 5 4 3 2 1
Loops 5-8
Pins 1-8
To Adapter
RJ-45
Connector
To Norstar KSU
1 4 7
2 5 8
3 6
POWER
DS - 30
FIBER OPTIC
KSU 5 - 8
KSU 1 - 4
FIBER
LINE
DS-30/Station Port Adapter
Figure 3. Installation Diagram
Norstar KSU Applications Module
Fiber
Spool
4
Installation Guide DS30/Station Port Adapter
SITUATION INDICATION LINK ACTION
Fiber Line LED light is Power on Invalid Check fiber
flashing connection between
units
Fiber Line LED light is off No Power Invalid Check power source
Fiber Line LED light is on Power on Valid None
TCM Loop LED port light Active port Valid None
is on connection
TCM Loop LED port light Inactive port Invalid Check corresponding
is off connection port connection
TROUBLESHOOTING
Table 3. Troubleshooting Guide
NOTE: Timing master uses highest numbered TCM Loop connected
port to synchronize DS-30 link.
The DS30/Station Port Adapter is compatible with ACCESS 2.6
ver. 6.52 and higher within application products running on the
NAM II platform. Systems with previous versions of ACCESS
should obtain an appropriate upgrade.
Figure 4. Close-up View of LEDs
TCM Loop 1
Fiber Line
1 4 7
2 5 8
3 6
FIBER
LINE
••••••••••••••••••••••••••••••••••••••••
Norstar is a trademark of Northern Telecom.
P0878745 Issue 01
Printed in the United States
878745-Prt Adpter B Cov Page 1 Monday, December 1, 1997 10:50 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Nortel Networks DS30 User manual

Category
Network media converters
Type
User manual

Nortel Networks DS30 is a device that multiplexes up to eight Nortel Norstar TCM Loops (up to 16 voice paths) into one DS-30 fiber optic line. Each TCM Loop may include up to two active voice/data paths as well as a control signaling path. It's compatible with ACCESS 2.6 ver. 6.52 and higher within application products running on the NAM II platform. The device has a mean time before failure (MTBF) target of greater than 20 years.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI