Robertshaw Slip-fit® Dial (For 4200 Series) User manual

Type
User manual

Robertshaw Slip-fit® Dial (For 4200 Series) allows for precise temperature control in various applications. After mounting the control, you can customize the dial's "low-stop" position and index pointer alignment. The blank dial and temperature scale insert ensure easy setup and a clean look. Installation is simple, but requires careful alignment of the tabs to ensure proper fit. The dial can be removed for cleaning or replacement of the temperature scale insert.

Robertshaw Slip-fit® Dial (For 4200 Series) allows for precise temperature control in various applications. After mounting the control, you can customize the dial's "low-stop" position and index pointer alignment. The blank dial and temperature scale insert ensure easy setup and a clean look. Installation is simple, but requires careful alignment of the tabs to ensure proper fit. The dial can be removed for cleaning or replacement of the temperature scale insert.

INSTALLATION DATA
Slip-fit
®
dial
(for 4200 SerieS)
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
Robertshaw®, Ranco®, Paragon® and Uni-Line® are
trademarks of Robertshaw, its subsidiaries and/or
affiliated companies. All other brands mentioned
may be the trademarks of their respective owners.
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7294
www.uni-line.com
www.robertshaw.com
©2014 Robertshaw
09/14 – 1-211 RevB
1. Mount the new kit control according to
 theinstruconsheet.
2. Aerthecontrolisinstalled,placethe
 blankdialontothedialsha.Turnthedial
 clockwiseunlitstops.Thisisthe
 “low-stop”posion.
3. Decidewhichdireconyouwantthe
 “low-stop”posion(thewordRobertshaw)
 onthedialtoread;up,right,leordown.
If the index pointer is desired, and it needs
to be located to match the “low-stop”
 posionofthedial,seetheinstrucons
packaged with the control.
4. Take a pencil and lightly mark on the
outside edge of the blank dial where the
 “low-stop”posionisgoingtobe.
5. Removetheblankdialandplaceitonaat
surface. Take the temperature scale insert
and hold it over the dial, lining up the
word Robertshaw with the pencil mark.
DO NOT PUSH, but let it fall down onto the
knob. STOP! DO NOT PUSH THE INSERT
YET.
6. THIS STEP IS VERY IMPORTANT AND
MUST BE FOLLOWED CAREFULLY. READ
THIS WHOLE SECTION BEFORE
PROCEEDING FURTHER. Make sure that
 “low-stop”(thewordRobertshaw)isgoing
 tobeinthecorrectposion.Makesure
 thatallfourtabs(seegure2)tinsidethe
edge of the blank dial. If one tab is slightly
 o,useangernailandbenditinslightly.
Double check to see that all the tabs now
 tinsideoftheblankdial.Slowlypressthe
 insertallthewaydown(seegure2).
7. If removal of the temperature scale insert
 isnecessary,pullthedialoofthedial
 sha.Usingasmallbluntobject,likeadull
pencil point, push out the insert using the
 tworemovalopeningsprovided(see
 gure1).
“LOW-STOP”
POSITION
(THEWORD
ROBERTSHAW)
LOCATING RIBS
(FOUR)
REMOVAL
OPENING
BLANK
DIAL
TEMPERATURE
SCALEINSERT
FIGURE 1 FIGURE 2
TAB TAB
  • Page 1 1

Robertshaw Slip-fit® Dial (For 4200 Series) User manual

Type
User manual

Robertshaw Slip-fit® Dial (For 4200 Series) allows for precise temperature control in various applications. After mounting the control, you can customize the dial's "low-stop" position and index pointer alignment. The blank dial and temperature scale insert ensure easy setup and a clean look. Installation is simple, but requires careful alignment of the tabs to ensure proper fit. The dial can be removed for cleaning or replacement of the temperature scale insert.