Panasonic TYCE42PS1 Operating instructions

Type
Operating instructions
Takupphängningsenhet för
bred plasmaskärm
Installtionsanvinsnigar
Läs noga igen dessa anvisningar innan monteringen startas.
Förvara detta häfte nära till hands för framtida referens.
Loftophæng til
Widescreen-plasmaskærm
Monteringsvejledning
Læs venligst denne vejledning, før du forsøger at samle dette
tilbehør. Gem denne vejledning til senere brug.
Unidad de techo para pantalla
panorámica de plasma
Instrucciones de instalación
Antes del montaje de este accesorio, lea completamente
estas instrucciones. Y guárdelas para utilizarlas como
referencia en el futuro.
Support plafond pour grand écran à
plasma
Instructions d’installation
Lisez attentivement ce document avant d’assembler les
pièces. Conservez ce document pour référence.
Unità a soffitto per schermo grande
al plasma
Instruzioni per I’installazione
Prima di cominciare a montare queste parti componenti,
leggere completamente queste istruzioni. Conservare questo
libretto per consultazioni future.
Plafondbevestiging voor Breedbeeld
Plasmadisplay Monitor
Installatiehandleiding
Lees deze installatiehandleiding zorgvuldig door voordat u de
onderdelen monteert. Bewaar de handleiding voor eventuele
naslag in de toekomst.
Deckeneinheit für Plasmadisplay
Installationsanleitung
Bitte lesen Sie vor dem Zusammenbau dieses Zubehörs die
Anleitung vollständig durch.
Bitte bewahren Sie diese Anleitung zum späteren
Nachschlagen auf.
Ceiling Unit for Wide Plasma Display
Installation Instructions
Before attempting to assemble these accessories, please
read these instructions completely.
Please retain this book for future reference.
English
Deutsch
Nederlands
Italiano
Français
Español
Svenska
Dansk
TQZH241-2
TY-CE42PS1
MODEL No.
English
2
Thank you very much for purchasing the Panasonic Wide Plasma Display Ceiling
unit.
Installation should only be carried out by a qualified technician.
• If the unit is installed incorrectly, the display may fall and personal injury may result.
Precautions when setting up
WARNING
Observe all safety requirements and ensure that the installation location can bear heavy
loads.
• If the installation location is not strong enough, the display may fall and personal injury may
result.
Do not install in locations unable to bear heavy loads such as plaster board, ceiling tiles
and the like.
• If the installation location is not strong enough, the display may fall and personal injury may
result.
CAUTION
Do not install in locations subject to high humidity, dust, oil fumes, water vapour or
excessive heat.
• These can have adverse effects on Wide Plasma Display operation, and fire or electric shocks
may result.
Do not install the Wide Plasma Display face up, sideways or upside down.
• Doing so may cause heat to build up inside the display, and fire may result.
Two people are needed to install and remove the display.
• If two people are not present, the display may fall and personal injury may result.
Maintain at least 10 cm (3
15
/16 in.) clearance at the top, bottom, sides and rear of the
display.
• The display has air outlet holes at the top and air intake holes at the bottom and rear. These
holes must not be covered, otherwise fire may result.
3
English
Components
Ceiling unit.......................1
Allen key..........................1
Fixing bolt
(M8-12) ................2
Washer pan nut
(M8)......................1
Points to note during installation
This ceiling unit is for mounting a Wide Plasma Display to a ceiling for viewing purposes.
Do not use it for any type of installation other than ceiling mounting.
In order to ensure correct, problem-free operation of the Wide Plasma Display, do not
install the Display in any of the following places:
• Next to sprinklers or sensors
• Where it may be subject to vibration or shocks
• Near high-voltage wires or electric motors
• Where it may be in direct contact with air from heaters
When installing this ceiling unit, use a fixing method appropriate to the type of ceiling.
Use an M12 bolt (sold separately) appropriate for the type of ceiling material (wood, steel
frame, concrete, etc.) the ceiling unit is to be mounted on.
Insert the mains plug for the Wide Plasma Display into a mains socket which is close and
easily accessible.
Provide adequate ventilation so that the temperature around the display does not rise
above 40°C (104 F°). If there is insufficient movement of the air inside the display, heat
may build up inside the display and fire may result.
Cable tie..........................2
Insulating spacer
........................4
Fixing bolt
(M8-20) ................2
Spring washer
........................1
Toothed pan washer
........................4
Fixing screw
(M5)......................2
Fixing bolt
(M8-100) ..............1
Pan head bolt with
hex socket (M8-45)
........................4
4
English
Installation procedure
This ceiling unit weighs approx. 19kg (41.9lbs).
The display weights approx. 33kg (72.8lbs) to
45kg (99.2lbs). Refer to the diagram on the right
and confirm that the four points for mounting the
ceiling unit and display are capable of bearing
this weight. If the installation location is not
strong enough to bear this weight, reinforce the
ceiling before the ceiling unit and display are
installed.
300 (11
13
/16)
300 (11
13
/16)
350 (13
25
/32)
Ceiling installation holes
Front
24 (
15
/16)
14 (
35
/64)
R7
(R
9
/32
)
Reinforce the ceiling if it is not strong enough.
Use bolts appropriate for the ceiling material (not supplied).
Refer to the installing examples for wooden structure and concrete structure.
Note
Note
3. Install the ceiling unit
(upper section).
Flat washer
(not supplied)
Spring washer
(not supplied)
M12 bolt
(not supplied)
Earthed mains extension lead
(example)
Signal cable
(example)
1. Before installing the upper section, pull
the wiring through the pipe. Use an
earthed mains extension lead (not
supplied).
2. Make holes in the ceiling using a
method appropriate for the ceiling
structure and for inserting M12mm
bolts. Install the upper section using a
hex socket bolt (M12 not supplied), flat
washer and spring washer.
1. Check the strength of the installation location.
2. Prepare the ceiling unit.
Ceiling unit
(upper section)
M8 assembly screw
Ceiling unit
(lower section)
Remove the two M8 assembly screws
from the ceiling unit and separate the
upper and lower sections of the unit.
Units
: mm (in.)
M12 bolt
Spring washer
Flat washer
curled plug(M12)
Anchor nut or
Concrete
Installing to a concrete structure(example)Installing to a wooden structure(example)
M12 bolt
Spring washer
Flat washer
Flat washer
Nut
Beam
"
]
)(min.thickness 40mm [1
9
/
16
Mounting plate
Ceiling board
Nail
5
English
4. Attach the ceiling unit (lower section).
When adjusting the height, no more that 4 holes should
be visible. (The white line should not show.)
Note
Washer pan nut
Spring washer
Fixing bolt M8-100
M8 bolt
M8-12
Hidden
side
Ceiling unit
(upper section)
M8 assembly screw
M8 assembly screw
White line
(Example)
Ceiling unit
(lower section)
Distance from
center of display
to ceiling ( in.)
Center of
display
Height adjustment
holes
1085mm (42
23/32
)
985mm (38
25/32
)
885mm (34
27/32
)
785mm (30
29/32
)
1. Match the height adjustment holes on
the upper and lower sections to the
desired height and refasten in place
with two M8 assembly screws.
2. Insert the fixing bolt (M8-100) through
the spring washer and then insert it
through the uppermost hole in the pipe.
Fasten in place with the washer pan
nut (all included).
3. Tighten with two fixing bolts (M8-12,
included) so that the lower section
does not move.
5. Prepare the display.
Remove the four bolts.
Pan head bolt with hex socket
Toothed pan washer
Insulating spacer
1. Remove the four bolts from the display.
2. In each of the four bolt holes, insert a
pan head bolt with hex socket (M8-45),
toothed pan washer and insulating
spacer (four each, all included). Insert
as shown in the diagram on the left.
Install the insulating spacers in the display unit.
Lay the display with the screen facing down on a clean blanket or sheet and follow the steps
below.
6
English
Insulating spacer
Notch
Notch
6. Mount the display in the ceiling unit.
1. Hook the displays top insulating
spacers in the ceiling unit by aligning
the display with the notches in the
ceiling unit and sliding the display
downward.
2. Insert the bottom insulating spacers by
lifting the display slightly, fitting the
bottom spacers into the holes, and then
lowering the display.
When mounting the display in the ceiling unit, be
sure the ceiling unit is straight and not at an angle.
Note
Do not lift the display too high. It may come unhooked from the unit.
Caution
7. Fix the display.
Fixing screw (M5) 1 each
left and right sides
Install two fixing screws (M5, included)
in the corresponding holes on the ceiling
unit (left and right).
8. Adjust the ceiling unit's direction.
M8 bolt
M8-20
Adjust the angle of the display and fix in
place with two fixing bolts (M8-20,
included).
Install the fixing screws on the left and right to prevent the display from sliding out of the ceiling unit.
Note
Installation procedure
7
English
Removing the display
10. Gather the cables.
Cable
Cable tie
Cable tie
Cable
This ceiling unit can be placed in 7 angles from 0°
to 30° in 5° increments. The factory setting is 0°.
If you wish to change the angle, remove the angle
adjustment screws from the connecting pipe and
adjust the angle adjustment holes to the desired
position. Then reinsert the screws.
9. Adjust the ceiling unit's angle.
1. Remove the two fixing screws (M5) at
the left and right sides of the ceiling
unit.
2. Lift the lower part of the display,
pull outward
and lift upward.
Insulating
spacer
Fixing screw (M5)
Gather the cables connected to the
terminals on the back of the display and
fix in place with a cable tie.
When removing the display, first return the ceiling
unit angle to 0°.
Caution
8
English
(For U.S.A)
Warranty
Panasonic Consumer Electronics Company
Division of Matsushita Electric Corporation
of America
One Panasonic Way
Secaucaus, NJ
07094
RACKS AND STANDS
Panasonic Consumer Electronics Company or Panasonic Sales Company (collectively referred to as the
warrantor ), will replace parts in case of defects in materials or workmanship, free of change, in the USA or
Puerto Rico, for ten (10) days from the date of the original purchase.
In-warranty parts in the USA can be obtained during the warranty period be contacting:
Panasonic Services Company (PASC)
20421 84th Avenue South
Kent, Washington 98032
Tel.:1-800-833-9626
Fax.:1-800-237-9080
(6 am to 5 pm Monday-Friday; 6 am to 10:30 am Saturday; PST)
Service in Puerto Rico can be obtained during the warranty period by calling the telephone number listed above.
This warranty is extended only to the original purchaser. A purchase receipt or other proof of the original
purchase is required for replacement parts under the warranty.
This warranty only covers failures due to materials and workmanship and does not cover normal wear. The
warranty does not cover damages which occurred in shipment or failures which result from accidents, misuse,
abuse, neglect, mishandling, misapplication, faulty installation, set-up adjustments, improper maintenance,
alteration, line power surge, lightning damage, modification,or commercial use, such as hotel, office,
restaurant, or other business or rental use of the product, or damage that is attributable to acts of God.
LIMITS AND EXCLUSIONS
There are no express warranties except as listed above.
PANASONIC SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE RESULTING
FROM THE USE OF THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. ALL
EXPRESS AND IMPLIED WARRANTIES. INCLUDING THE WARRANTIES OF MERCHANTABILITY, ARE
LIMITED TO THE APPLICABLE WARRANTY PERIOD SET FORTH ABOVE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on
how long an implied warranty lasts, so the above exclusions or limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
If a problem with this product develops during or after the warranty period, you may contact your dealer or call
the number listed above.
If the problem is not handled to your satisfaction, then write to the Customer Satisfaction Center at the
Panasonic Consumer Electronics Company address indicated above.
Panasonic Sales Company, Division of
Matsushita Electric of Puerto Rico, Inc.
AVE. 65 de Infanteria, Km 9.5
San Gabriel Industrial Park
Carolina, Puerto Rico 00985
Matsushita Electric Industrial Co., Ltd
Web Site : http://www.panasonic.co.jp/global/
Printed in Japan
M0600-2052
(Recycled paper)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Panasonic TYCE42PS1 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI