Midmark Procenter Systems offer a range of innovative features to enhance dental procedures. With a user-friendly interface, these systems provide precise control over water and air tools, allowing for efficient and accurate treatments. The cuspidor's integrated design seamlessly complements the dental chair, ensuring a comfortable experience for both dentists and patients. Additionally, the Procenter Systems are designed to promote infection control, featuring easy-to-clean surfaces and a flushable bowl for optimal hygiene.

Midmark Procenter Systems offer a range of innovative features to enhance dental procedures. With a user-friendly interface, these systems provide precise control over water and air tools, allowing for efficient and accurate treatments. The cuspidor's integrated design seamlessly complements the dental chair, ensuring a comfortable experience for both dentists and patients. Additionally, the Procenter Systems are designed to promote infection control, featuring easy-to-clean surfaces and a flushable bowl for optimal hygiene.

1
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
003-2035-00 Rev. D (2/13/15)
Procenter Cuspidor or Cuspidor/Assistant’s Unit Combo,
Rear Mounted on an Elevance Chair Installation Guide
Note
Cuspidor is wrapped and sealed in a box to protect the glass. Carefully inspect parts before installing.
DA2416i
Removing the Chair Pivot Switch Bracket
Step 1: Raise chair to a comfortable working height. (Chair should
be at least 10"- 15“ above floor.)
Switch
Bracket
Chair Pivot
Language of origin: English
Note
Tap any one of the lift arm covers 3 times to raise the chair to
the pre-programmed “home” position, a convenient height for
installation or patient access. The chair beeps as it moves
and stops beeping when it reaches the home position.
WARNING
Always disconnect power before removing covers. Failure to do
so may result in personal injury.
Step 2: Remove chair pivot switch bracket (two shoulder bolts in
the slotted holes and two screws in bottom).
NextNext
BackBack
midmark.com
Style G
2
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
Removing the Lift Arm Covers
DA2418i
Step 1: Push in with a screwdriver to release the clip on each side
and pull up to remove the top lift arm cover.
Note: Top lift arm cover has a clip that fits over the dowel rod on the front of the chair.
Top Lift Arm Cover
Step 2: The bottom lift cover hangs from 4 mounting pins on the
chair frame. Pull cover out to free from mounting pins, then
back as you maneuver the cover off the chair frame.
Mounting Pin
Bottom Lift
Arm Cover
NextNext
BackBack
midmark.com
Style G
3
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA2434i
Installing the Rear Mounted Cuspidor
Equipment Alert
Have an assistant support the Cuspidor mount arm and
steady all pivot points to prevent damage to the equipment.
Set Screws (4)
Set Screw
Adjustment
Step 4: After leveling mount arm (Step 2 and 3),
tighten all four hex screws to secure.
Step 1: Mount the cuspidor assembly on the chair pivot using four hex head screws and washers.
Step 2: Keep hex head screws tightened loosely. Level mount arm assembly
to the flooring using the four set screws.
Hex Head
Screws (4)
Step 3: Level the mount arm assembly with the
mounting holes by lifting either side.
NextNext
BackBack
midmark.com
Style G
4
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA137300i
Assemble the Cuspidor
Step 1: Position the Cuspidor over
the base and gently press
downward.
Step 2: Install faucet and gasket.
Step 3: Install bowl flush spout
and gasket.
Step 4: Install gold drain trap.
DA144700i
Cuspidor with Assistant’s Unit
option
NextNext
BackBack
midmark.com
Style G
5
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA2436i
1
Connecting the Tubing and Power on the Rear Mounted Cuspidor / Assistant’s Unit
(
See page 8 for additional wiring connections required for this installation without a Delivery unit)
Step 2: Use at least two ties to hold the wiring harness and vacuum
tubing together and loosely strapped to the chair frame.
Step 1: Remove bottom plate (two screws) and make the electrical
and tubing connections inside the chair frame.
Step 4: Install bottom plate (two screws) to support the wiring and tubing.
Bottom
Plate
Step 3: Connect tubing and electrical plugs as shown.
5/8" Vacuum
(ribbed line)
Power
(not used)
1/8" Air - yellow
1/4" Water - blue
Cuspidor connections
5/8" Drain
Remove 1/8" Air Line Cap
Remove Jumper
wire on Controls
plug
Remove
1/8" Water
Line Cap
Keypad
Controls
3/4" Vacuum
1/8"
Water
- blue
Barbed
Adapter
Assistant’s Unit connections
Umbilicals from Chair
NextNext
BackBack
midmark.com
Style G
Color Page
6
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
4
0
6
0
80
100
2
0
0
1
2
3
5
6
7
4
0
40
6
0
80
100
20
0
1
2
3
5
6
7
4
0
40
60
80
100
20
0
1
2
3
5
6
7
4
0
Cuspidor and Assistant’s Unit Combo J-Box Connections
Step 2: Remove plug from water shut-off valve.
Install 1/4" barb fitting.
Connect 1/4" blue tubing from umbilical.
Step 3: Connect 5/8" drain from
umbilical to facility drain.
Step 1: Remove lid from J-box.
Step 4: For Cuspidor with Assistant’s Combo unit ONLY!
Connect 3/4" vacuum from umbilical to facility’s central
vacuum (Not shown).
NextNext
BackBack
midmark.com
Style G
Color Page
7
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
DA2430i
Installing the Chair Pivot Covers and Lift Arm Covers
Step 3: Install upper pivot cover (two screws in chair pivot).
Step 1: Install switch bracket (two shoulder bolts in the
slotted holes and two screws in bottom).
Switch
Bracket
Upper Pivot Cover
Lower Pivot Cover
Step 2: Install lower pivot cover (slip slotted holes over
shoulder bolts in chair pivot).
Step 4: Install Lift Arm Covers (see Removing Lift Arm
Covers, on a previous page in this guide).
NextNext
BackBack
midmark.com
Style G
8
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
Procenter
Interface
PCB
Additional Wiring Connections Required for an Installation without a Delivery Unit
Step 1: Remove seat upholstery, seat shrouds and the
seat frame to access the toe-end of the chair.
Step 2: Install Procenter Interface PCB and mounting
bracket in the chair.
Seat Shroud (RH)
Seat Upholstery
Seat Frame
Step 3: Plug the Assistant’s Control Harness into J1 or J2
and plug the LIN connector into J4 on the Procenter
Interface PCB.
Step 4: Install seat frame, seat shrouds and
seat upholstery on the chair.
NextNext
BackBack
midmark.com
Style G
9
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
KA938903i
Adjust flow controls on cuspidor.
Cup Fill Button
Cup Fill
Adjustment
Knob Button
Bowl Flush
Adjustment
Knob
Bowl Flush
Button
NextNext
BackBack
midmark.com
Style G
10
© 2010 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 |
Installation Checklist
Test Description of good installation criteria
1 Mount Arm and Cuspidor and Assistant’s Unit are level.
2 Mount Arm and Assistant’s Unit rotate and move easily.
3
Mount Arm stays where placed without drifting. Adjust drag
on pivot points if necessary.
4
Chair Lift Arm covers are in place and limit switches activate
when covers are tapped.
5
Chair Pivot covers are securely in place and the limit switch
activates when cover lowers into an obstruction.
7
Air and Water tools work on the Assistant’s Unit - no wires or
tubing are pinched by covers or mountings.
8
Wipe Cuspidor with a soft dry cloth to remove any dirt or
smudges.
9 Pressing Cup Fill button activates the Cup Fill function.
10
Pressing and holding the Cup Fill button runs water thru the
spout, until button is released.
11
Turning the Cup Fill Adjustment Knob allows you to modify
the amount of water the Cup Fill function delivers.
12 There are no leaks in the fill or drain connections or tubing.
DA2424i
Mount Arm
pivot points
Allen wrench
To Adjust drag on pivot points...
Tighten or loosen the set screw near the desired pivot point to
modify the pivot’s drag.
NextNext
BackBack
midmark.com
Style G
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Midmark Procenter Systems Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide

Midmark Procenter Systems offer a range of innovative features to enhance dental procedures. With a user-friendly interface, these systems provide precise control over water and air tools, allowing for efficient and accurate treatments. The cuspidor's integrated design seamlessly complements the dental chair, ensuring a comfortable experience for both dentists and patients. Additionally, the Procenter Systems are designed to promote infection control, featuring easy-to-clean surfaces and a flushable bowl for optimal hygiene.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI