Overview
The Extron EWB 1000 wall box is
an optional accessory for mounting
the TLP 1000MV touchpanel onto
the surface of various wall types
(such as drywall, wood, or masonry)
where it is not possible to embed
the touchpanel in the wall. The
EWB 1000 has knockouts that
accept raceways or conduit for
running cables over the surface of
the wall to the touchpanel.
Planning
The following items are required
for installation, but are not
supplied:
z Extron TLP 1000MV
z Four mounting screws (Extron
recommends a minimum length
of 1 inch)
z Power drill
z Drill bit that is appropriate for
wall type
z Conduit or surface raceway to carry cables
z Screwdriver
z Level
Mounting Suggestions for Different Wall Types
Choose a type of screw or bolt that is appropriate for the wall on which you are mounting
the EWB 1000 (see table below). The mounting holes in the back of the EWB 1000
accommodate screws up to ¼ inch in diameter.
Wall Type Fasteners Min. Size
Fastener
Quantity Drill Bit
Size
Notes
Drywall Toggle bolts 3/16 inch 4 1/2 inch Min. 3/8 inch
wall thickness
Wood
(solid wall
or stud)
Wood screws #10 screw
with a
washer
4 1/16 inch
wood bit
Min. 3/8 inch
wall thickness
Masonry Masonry
screws
1/4 inch 4 3/16 inch
masonry bit
Do not mount to
masonry joints
Extron
EWB 1000
Wall Box
Extron
TLP 1000MV
Extron
TLP 1000MV
Faceplate