American Dynamics RCTT16BE Installation guide

Category
Motorcycle Accessories
Type
Installation guide

This manual is also suitable for

RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
1 of 15
View Manager
16 Plus
Enhanced TOUCH
TRACKER
®
Installation Guide
A
B
C
D
1
2
3
4
5
6
7
8
9
0
P
e
e
l
I
n
f
o
O
n
O
u
t
p
u
t
O
f
f
C
l
e
a
r
M
e
n
u
I
r
i
s
C
l
o
s
e
O
p
e
n
F
l
i
p
V
i
e
w
P
a
t
t
e
r
n
R
e
p
e
a
t
P
a
t
t
e
r
n
S
e
q
P
r
e
v
i
o
u
s
N
e
x
t
RCTT16BE
Contents
About this Guide................................................................... 1
Changes from Prior Version ......................................... 1
TOUCH TRACKER Installation................................................. 2
Installation Diagrams............................................................ 3
Installation Notes .......................................................... 3
Enhanced TOUCH TRACKER with Multiplexer
(DB25 connection)........................................................ 4
Enhanced TOUCH TRACKER with Multiplexer
(RJ11 connection) ........................................................ 5
Enhanced TOUCH TRACKER with Quad Splitter
(RJ45 connection) ........................................................ 6
Enhanced TOUCH TRACKER with RVQX7X Quad
Splitter........................................................................... 7
Enhanced TOUCH TRACKER with Intellex 1.x ................ 8
Enhanced Touch Tracker with Intellex 2.0 ................... 9
Enhanced Touch Tracker with Intellex 2.1 ................. 10
Enhanced TOUCH TRACKER and Duplex Remote Panel
(RVDRP)..................................................................... 11
Enhanced TOUCH TRACKER with Domes Only
(No External Unit) ....................................................... 12
Configuring the External Device......................................... 13
Setting Primary and Secondary Unit.................................. 13
Additional Touch Tracker Tasks......................................... 14
Displaying System Information................................... 14
Performing the SensorNet Ping Test.......................... 14
Resetting a Dome ....................................................... 14
Adjusting V-Phase ...................................................... 14
Specifications ..................................................................... 15
SensorNet................................................................... 15
Enhanced Touch Tracker ........................................... 15
Declarations ....................................................................... 15
Regulatory Compliance .............................................. 15
© 2005 Sensormatic Electronics Corp.
About this Guide
These installation instructions explain how to setup
the VM16+ Enhanced T
OUCH TRACKER. Other relat-
ed documents are:
System Operator's Manual, 8000-2653-01
Quick Reference Guide, 8000-2654-01
If you need assistance...
Contact your Sensormatic Representative.
Changes from Prior Version
Significant changes are noted with revision bars in
margins.
Updated bill of materials for RVEIMKITE.
Moved location of installation diagrams in
document.
Updated wiring diagrams for Intellex units and
Duplex Remote Panel.
Updated Regulatory Compliance statement.
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
2 of 15
!
TOUCH TRACKER Installation
RVEIMKITE TOUCH TRACKER Installation Kit
Part Number Description Quantity
6003-0047-01 CBL/A, MDR, 14',8 C,CROSS-P'D 1
5899-0004-102 SCR, TCUT, M2.9X9.5, PHP, ST,Z,T1 1
2880-0083-01 ANCH, PL, W/O SCR, 3/4L,#4-#6-#8 2
2816-7634-44 SCR, TYP AB, PHP, ST, Z, 8X1 2
2109-0254-04 CON, P, EUR,.2C,28-12G,1X5P 1
2141-0002 LUG, SPADE, INSUL, 22-168 3
6002-0024-01 CBL, 3C, 18G, CM 16.5
0649-0006-02 BAG PLASTIC 4 X 6 1/2 4MIL 1
0649-0006-04 BAG PLASTIC 8 X 10 4 MIL THK 1
2450-0008-01 LBL, BLNK, PAP, THERM, 89X76M, RL 1
3600-0032-01 PRINTING SPEC, LABEL 0
0300-1000-01 INTERCONNECT BOX, TOUCH TRACK 1
6003-0107-01 CBL/A, QUAD, SW, INTFCE 1
2125-0007-02 HOOD, D, 9P, EMI/RFI, 1/4 D CBL 1
2130-0021-01 CON, D,P, HSG, 9P, SSI 1
2103-0092-01 CONT, P, D, 26-22,AU 3
0650-1079-01 CABLE ASSY, VM8 TOUCHTRACKER/VI 1
8000-2672-01 INSTL INSTRS, TT ENHANCED 1
0649-0006-06 BAG, PLASTIC 12-1/2 X 14X4MIL 1
8000-2653-01 SYS OPERATOR'S MANUAL, VM16 1
8000-2654-01 SYS QUICK GUIDE, VM16 1
8000-1370-02 TTRACKER STRAIN RELIEF INSTR 1
6003-0108-01 CBL/A, VM16+/TNG, MUX/INTFCE 1
RPNR00 CBL/A, RS-232, 10', DB9F-DB9M 1
For Quad Splitter (RVQX7X) with DB9 Connector
These additional parts are required.
PN Description Quantity
2125-0007-02 DB9 Hood 2
2103-0092-02 DB9 Female contact pins 5
2103-0092-01 DB9 Male contact pins 5
2130-0021-01 DB9 Male Connector 1
2130-0022-01 DB9 Female Connector 1
WARNING: RISK OF ELECTRIC
SHOCK! Disconnect AC Power to
the switch.
CAUTION-Electrostatic Sensitive
Device: Follow proper handling
procedures to prevent component
failure.
Note: Prior to installing the Enhanced TOUCH
TRACKERS, identify the type of external unit that will
connect to the Enhanced T
OUCH TRACKER, if
applicable. Build any cables that are required.
Refer to the Installation Diagrams starting on
page 3 for specific instructions.
1. Terminate the External Interconnect Module
(EIM) at the end of the SensorNet network. If
more than one Enhanced T
OUCH TRACKER
controller will be installed, one TOUCH
TRACKER's EIM will be terminated; the other EIM
will be unterminated. Refer to the appropriate
wiring diagram for your configuration.
2. Mount each EIM on a wall or other surface
within 3m (10 feet) of the Touch Tracker
controller.
3. Connect the power transformer and SensorNet
cable to J3 on each EIM. If two Touch Trackers
will be installed, connect the SensorNet cable
from the first EIM to the second EIM.
4. Depending on the external unit that will be
attached to your system, connect the
appropriate cable to the DB9 connector on the
EIM. Refer to the appropriate wiring diagram for
additional details.
5. Connect the data cable from J1 on the Primary
T
OUCH TRACKER's EIM to the remote port on the
external unit. Refer to the appropriate wiring
diagram for additional details.
6. Connect the modular cable from J2 on each
EIM to the T
OUCH TRACKER controller.
7. Connect the SensorNet cable from the dome to
the first EIM. Refer to the appropriate wiring
diagram for additional details.
8. Plug in the power transformer into a grounded,
3-wire receptacle.
Note: If the keypad and backlighting do not
illuminate when power is applied, unplug each
power transformer and repeat steps 3 through 8.
Depending on system configuration, it may take up
to 2 minutes for the Enhanced T
OUCH TRACKER to
come completely online.
Continue with Configuring the External Device.
!
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
3 of 15
Installation Diagrams
The following pages illustrate the installation of the
VM16+ Enhanced Touch Tracker in the following
configurations:
Enhanced Touch Tracker with Multiplexer
(DB25 connection)................................................4
Enhanced Touch Tracker with Multiplexer
(RJ11 connection) ................................................5
Enhanced Touch Tracker with Quad Splitter
(RJ45 connection) ................................................6
Enhanced Touch Tracker with RVQX7X Quad
Splitter ...................................................................7
Enhanced T
OUCH TRACKER with Intellex 1.x ...... 8
Enhanced Touch Tracker with Intellex 2.0.........9
Enhanced Touch Tracker with Intellex 2.1.......10
Enhanced Touch Tracker and Duplex Remote
Panel (RVDRP) ...................................................11
Enhanced T
OUCH TRACKER with Domes Only (No
External Unit) ......................................................12
Refer to the appropriate diagram when connecting
the Enhanced Touch Tracker.
Installation Notes
Depending on configuration, two Enhanced
TOUCH TRACKERS may be installed. Terminate
E1 on the EIM that is on the end point of the
SensorNet Network.
The maximum combined SensorNet cable
length is 1000 m (one km or 3000').
J-Box and dome wiring information is included
for information purposes only. Refer to the
J-Box or dome installation instructions for
complete wiring information.
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
4 of 15
Enhanced TOUCH TRACKER with Multiplexer (DB25 connection)
COLOR
Orange
1Host A
Yellow 2 Host B
Orange
Auxiliary A
Yellow 4
Auxiliary B
PIN FUNCTION
COLOR
Orange
1
SensorNet A
White 2 28 Vac
Red 3
Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
5 Ground
2 Tx
DB9M
COLOR
BLACK 14 Ground
25 RxRED
DB25M
Your system supports up to
2 controllers. Terminate E1
on the EIM that is on the
end point of the SensorNet
Network.
The maximum combined
SensorNet cable length is
1000 m (3000').
Connect to
Remote
DB25F
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
5 of 15
Enhanced TOUCH TRACKER with Multiplexer (RJ11 connection)
COLOR
BLACK 5
2
GROUND
TRANSMIT
RED
PIN FUNCTION
COLOR
Orange
1
Host A
Yellow
2
Host B
Orange
Auxiliary A
Yellow 4
Auxiliary B
PIN FUNCTION
COLOR
Orange
1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
To D ome
Refer to instructions
included with device.
Your system supports up to
2 controllers. Terminate E1
on the EIM that is on the
end point of the SensorNet
Network.
The maximum combined
SensorNet cable length is
1000 m (3000').
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
6 of 15
Enhanced TOUCH TRACKER with Quad Splitter (RJ45 connection)
COLOR
5
TRANSMIT
GROUND
RED
ORANGE
PIN FUNCTION
COLOR
GREEN
2
5
TRANSMIT
GROUNDORANGE
PIN
FUNCTION
COLOR
GREEN 5
2
RED
ORANGE
PIN
COLOR
Orange
1
Host A
Yellow
2
Host B
Orange
Auxiliary A
Yellow 4
Auxiliary B
PIN FUNCTION
COLOR
Orange
1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
To D ome
Refer to instructions
included with device.
The maximum combined
SensorNet cable length is
1000 m (3000').
TERMINATED
Only one Touch Tracker
may be installed with the
dual page Quad Splitter.
This EIM must be
terminated.
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
7 of 15
Enhanced TOUCH TRACKER with RVQX7X Quad Splitter
COLOR
Orange
1Host A
Yellow 2 Host B
Orange
Auxiliary A
Yellow 4
Auxiliary B
PIN FUNCTION
EIM DB9M
2 Tx
5 Ground
2 Rx
1 Ground
COLOR
Orange
1 SensorNet A
White
228 Vac
Red 3
Ground
Black 4 28 Vac
Yellow 5 SensorNet B
PIN FUNCTION
To Dome
Refer to instructions
included with device.
PART QTY PN
DB9 Hood 2 2125-0007-02
DB9 Female contact pins 5 2103-0092-02
DB9 Male contact pins 5 2103-0092-01
DB9 Male Connector 1 2130-0021-01
DB9 Female Connector 1 2130-0022-01
Only one Touch Tracker may
be installed with the Quad
Splitter. This EIM must be
terminated.
TERMINATED
The maximum combined
SensorNet cable length is
1000 m (3000').
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
8 of 15
Enhanced TOUCH TRACKER with Intellex 1.x
J-B ox #1
EIM #1
DB9M
RJ45
RJ45
ASSY
0301-0340-01 REV-
3 2
1
TERMINATED
DB9F
P1
P2
P3
P4
P5
P6
P8
Primary
Touch Tracker
Intellex 1.x
(with DB9 Connector)
24 Vac A
24 Vac B
Ground
Straight-Thru Cable
PN: RPNR00
E1
To Dome
Refer to instructions
included with device.
5 4 3 2 1
Only one Touch Tracker
may be installed with
Intellex. This EIM must
be terminated.
DB9 Connector
Straight-Thru Cable Wiring
EIM DB9F COM 1
2 Tx 2 Rx
3 Rx 3 Tx
5 Ground 5 Ground
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
The maximum combined
SensorNet cable length
is 1000m (3000’).
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
9 of 15
Enhanced Touch Tracker with Intellex 2.0
J-B ox #1
EIM #1
DB9M
RJ45
RJ45
ASSY
0301-0340-01 REV-
3 2 1
Terminated
DB9F
P1
P2
P3
P4
P5
P6
P8
Primary
Touch Tracker
Intellex 2.0
(with DB9 Connector)
24 Vac A
24 Vac B
Ground
Straight-Thru Cable
PN: RPNR00
E1
To Dome
Refer to instructions
included with device.
5 4 3 2 1
Only one Touch Tracker
may be installed with
Intellex. This EIM must
be terminated.
COM 2
DB9 Connector
COM 1
Straight-Thru Cable Wiring
EIM DB9F COM 2
2 Tx 2 Rx
3 Rx 3 Tx
5 Ground 5 Ground
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
The maximum combined
SensorNet cable length
is 1000m (3000’).
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
10 of 15
Enhanced Touch Tracker with Intellex 2.1
J-Box #1
DB9M
P1
P2
P3
P4
P5
P6
P8
Intellex 2.1
(with DB9 Connector)
DB9F
Straight-Thru Cable
PN: RPNR00
To Dome
Refer to instructions
included with device.
RJ45
RJ45
Primary
Touch Tracker
Secondary
Touch Tracker
COM 1 DB9 Connector
Call monitor feature board
is used if Secondary Touch
Tracker is installed.
Your system supports up to
2 controllers. Terminate E1
on the EIM that is on the
end point of the SensorNet
Network.
Straight-Thru Cable Wiring
EIM DB9F COM 2
2 Tx 2 Rx
3 Rx 3 Tx
5 Ground 5 Ground
J-Box P8
Color Pin Function
Orange 1 Host A
Yellow 2 Host B
Orange 3 Auxiliary A
Yellow 4 Auxiliary B
J-Box P1-P6
Color Pin Function
Orange 1 SensorNet A
White 2 28 Vac
Red 3 Ground
Black 4 28 Vac
Yellow 5 SensorNet B
The maximum combined
SensorNet cable length
is 1000m (3000ft).
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
11 of 15
Enhanced TOUCH TRACKER and Duplex Remote Panel (RVDRP)
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
3 2 1
3 2 1
3 2 1
3 2 1
DOME 456
Jw2
DOME 123
Jw1
AUX
JW4
AUXHOST
HOST
Jw3
P8
P6
P5
P4
P3
P2
P1
T
T
T
T
To Your Remote
Mux Location
Pin 19
s-vhs
s-vhs
in
in
out
out
vcr
out
vcr
in
call
cam 1
in
out
cam 16
main
Pin 1
IN
OUT
Back View
REMOTE DUPLEX MUX (RVDRP)
RV2216 BACK VIEW
B
l
a
c
k
R
e
d
PRIMARY
TOUCH TRACKER
SECONDARY
TOUCH TRACKER
0300-1000-01
EIM #1
J2
J3
J1
DB9
RJ45
0300-1000-01
EIM #2
J2
J3
DB9
RJ45
J1
4
c
o
n
d
u
c
t
o
r
s
t
r
a
i
g
h
t
-
t
h
r
o
u
g
h
R
J
-
1
1
c
a
b
l
e
Pin 1
Pin 1
Pin 4
Pin 4
5
2
6003-0047-01
6003-0047-01
6
0
0
3
-
0
1
0
6
-
0
1
6
0
0
3
-
0
1
0
8
-
0
1
To Dome
Refer to instructions
included with device.
NOTE: Both ends of this
cable connect to the
ports labeled “data in”.
T=Terminated
U=Unterminated
NOTE: The Touch Tracker
is always connected to the
last output of the remote
multiplexers.
EIM DB9F Wiring
Color Pin
Red 2
Black 5
Note: Green wire is not used.
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
12 of 15
Enhanced TOUCH TRACKER with Domes Only (No External Unit)
Use this wiring diagram when domes will be connected to dedicated monitors.
COLOR
Orange
1 SensorNet A
Yellow 2 SensorNet B
Black 3 24 Vac A
Red 4 Ground
White 5
24 Vac B
PIN FUNCTION
COLOR
Orange
P1 Lead 5 SensorNet A
Yellow
P1 Lead 6 SensorNet B
Black P7 Lead 1 24 Vac A
Red P7 Lead 2 Ground
White P7 Lead 3 24 Vac B
PIN FUNCTION
Only one Touch Tracker may
be installed with standalone
configurations. This EIM must
be terminated.
The maximum combined
SensorNet cable length is
1000 m (3000').
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
13 of 15
Configuring the External
Device
Use this procedure to select the external device
that connects to the Enhanced T
OUCH TRACKER.
1. From the primary Enhanced T
OUCH TRACKER,
press Menu to configure the software for the
external system. The menu appears on the
LCD.
2. Use the Tracker Ball to scroll through the menu
until Config Devices appears on the LCD
screen. Press zoom or focus to select Config
Devices.
3. Press Next to scroll through the available
devices. Refer to the following chart to
determine which device to select.
Device Setting
Use with...
Device
=Mux 16
= POSEM
16-camera Multiplexer and
Intellex
Device
=Mux 9
= POSEM
9-camera Multiplexer
Device
=Mux 4
= POSEM
4-camera Multiplexer, dual page
Quad Splitter, and Quad Splitter
(RVQX7X)
Device
=Quad
= POSEM
Quad Splitter with DB9F-RJ45
connection
Device
=None
Domes connected to dedicated
monitors (no external device).
Device
=PC
For Service use only
4. When the correct configuration appears on the
LCD, press Menu.
Continue with Setting Primary and Secondary
Unit.
Setting Primary and
Secondary Unit
NOTE: Quad Splitter, Intellex 1.x and 2.0, and
stand-alone installations support only one Touch
Tracker.
If you have two Enhanced T
OUCH TRACKERS
installed, one must be designated as Primary; the
other must be designated as Secondary. If you
have only one Enhanced T
OUCH TRACKER installed,
it must be designated as Primary.
1. Press Menu.
2. Using the Tracker Ball, scroll the menu choices
until Tog Primary/2nd appears on the LCD.
3. Press zoom or focus to select Tog
Primary/2nd. Zoom selects the top line; focus
selects the bottom line.
4. Press Next to toggle between setting the
Enhanced T
OUCH TRACKER as primary or
secondary. When the appropriate choice
appears on the LCD, press Menu. The
Enhanced T
OUCH TRACKER will reset.
Repeat this procedure for each Enhanced T
OUCH
TRACKER.
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
14 of 15
Additional Touch Tracker
Tasks
The following maintenance functions can be
performed using the Touch Tracker. When using
the menus, pressing Zoom selects the first line of
the LCD; pressing Focus selects the second line of
the LCD.
Displaying System Information
This procedure displays system information about the
Enhanced T
OUCH TRACKER being used.
1. Use the number buttons to the select the dome to
reset, and then press
(Camera button).
2. Press Menu.
3. Using the Tracker Ball, scroll through the choices
until System Info appears on the LCD.
4. Press Zoom or Focus to select System Info.
5. Press Next or Previous to scroll through the
information.
The LCD displays the following information:
Unit Type: Primary or Secondary
ROM Checksum Values
Calibration information (display should read all
0)
Product Code Flash Version
Product Code EEPROM Version
6. Press Menu to resume camera control mode.
Performing the SensorNet Ping
Test
This procedure tests communications between the
Enhanced T
OUCH TRACKER and domes installed at
your facility.
1. Use the number buttons to the select the dome to
ping then press
(Camera button).
2. Press Menu.
3. Using the Tracker Ball, scroll through the choices
until Ping Dome/TTR appears on the LCD.
4. Press Zoom or Focus to select Ping
Dome/TTR.
5. Press Next to start the network test on the
primary or secondary Touch Tracker.
6. Press Menu to exit.
Note: Off-line domes or fixed cameras will generate a
warning beep and not permit the use of the Ping test.
Resetting a Dome
This feature allows you to reinitialize a SpeedDome
or SpeedDome Ultra family camera dome.
1. Use the number buttons to the select the dome
to reset then press
(Camera button).
2. Press Menu.
3. Using the Tracker Ball, scroll through the
choices until Reset Dome appears on the
LCD.
4. Press Zoom or Focus to select Reset Dome.
The Enhanced T
OUCH TRACKER sends a request to
the selected dome to reboot. After a brief delay, the
T
OUCH TRACKER resumes camera control mode.
Adjusting V-Phase
Use this procedure to adjust the vertical phase for
cameras installed with your system.
1. Press Menu.
2. Using the Tracker Ball, scroll through the
choices until Adjust V-phase appears on
the LCD.
3. Press Zoom or Focus to select Adjust V-
phase.
4. Press Next or Previous to observe V-phase
through the oscilloscope or Fluke scope.
5. When you are satisfied with the setting, press
Menu to exit.
Note: Off-line domes or fixed cameras will
generate a warning beep and not permit the use of
the V-phase utility.
RCTT16BE VM16 PLUS ENHANCED TOUCH TRACKER 8000-2672-01, REV. D1
INSTALLATION GUIDE
15 of 15
Specifications
SensorNet
Bit Rate:............................. 230.4Kbps
Physical Layer: ................. Non-shielded twisted
pair
Link Layer Protocol: .......... SDLC
Application Protocol: ......... Proprietary
Network Nodes: ................ Touch Tracker,
SensorNet Domes
Enhanced Touch Tracker
Operator Inputs: ............... 31-key keypad,
4 micro-switches,
1 Tracker Ball
Operator Outputs: ............. LCD screen
(2-line x 16 character)
Control Input/Output: ........ SensorNet (Domes,
Touch Tracker), RS-232
(multiplexer or quad
splitter)
Electrical
Power Source: .................. 16–30Vac at 50/60Hz
Power Consumption: ........ 1400mA, 2A max.
Mechanical, Touch Tracker
Height: .............................. 13cm (5in.)
Width: ............................... 19cm (7.5in.)
Depth: ............................... 26cm (10in.)
Weight: ............................. 1kg (2.2lbs)
Environmental
Operating Temperature: ... 0°–50°C
(32°–122°F)
Relative Humidity: ............ 0%–95%
non-condensing
Storage Temperature: ...... -20°–64°C
(-4°–149°F)
Product Compatibility
SensorNet Interface: ........ SpeedDome family
RS-232 Serial Port: .......... Monochrome Mux,
Color Mux,
Monochrome Quad,
Color Quad, Intellex,
Standard PC
Declarations
Regulatory Compliance
Emissions:.......................... FCC Part 15 Class A;
EN 55022 Class B.
Immunity: ...........................EN 50130-4
Safety Complies with:
UL1950;
CSA - C22.2 No 950-M89;
EN 60950.
FCC COMPLIANCE: This equipment has been tested and found to
comply with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: 1) this device may not cause harmful
interference, and 2) this device must accept any interference received,
including interference that may cause undesired operation.
EQUIPMENT MODIFICATION CAUTION: Equipment changes
or modifications not expressly approved by Sensormatic Electronics
Corporation, the party responsible for FCC compliance, could void the
user's authority to operate the equipment and could create a hazardous
condition.
Other Declarations
INSTALLATION: This installation should be made by a qualified
service person and should conform to all local codes. In North
America, this device is intended to be supplied from a nominal 24Vac
Class 2 power supply. In the EU, this device is intended to be powered
from a Certified (for the country of use), CE marked, source of SELV,
not exceeding 240 VA available.
INSTALLATION: Diese Installation sollte von einem qualifizierten
Wartungstechniker vorgenommen werden und allen örtlichen
Vorschriften entsprechen. In Nordamerika ist dieses Gerät für die
Stromversorgung durch ein Netzgerät der Klasse 2 mit einer
Nennleistung von 24 V Wechselstrom vorgesehen. In der EG ist dieses
Gerät für die Stromversorgung durch eine (für das Verwendungsland)
zertifizierte, mit der CE Marke versehene Schutzkleinspannungsquelle
(SELV) vorgesehen, die 240 V Wechselstrom nicht überschreiten darf.
WARRANTY DISCLAIMER: Sensormatic Electronics Corporation
makes no representation or warranty with respect to the contents
hereof and specifically disclaims any implied warranties of
merchantability or fitness for any particular purpose. Further,
Sensormatic Electronics Corporation reserves the right to revise this
publication and make changes from time to time in the content hereof
without obligation of Sensormatic Electronics Corporation to notify
any person of such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department of
Defense, all documentation and manuals were developed at private
expense and no part of it was developed using Government Funds.
The restrictions governing the use and disclosure of technical data
marked with this legend are set forth in the definition of “limited
rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013.
Unpublished - rights reserved under the Copyright Laws of the United
States.
TRADEMARK NOTICE: T
OUCH TRACKER, Sensormatic, and the
Sensormatic logo are trademarks or registered trademarks of
Sensormatic Electronics Corporation. Other product names mentioned
herein may be trademarks or registered trademarks of Sensormatic or
other companies.
No part of this guide may be reproduced in any form without written
permission from Sensormatic Electronics Corporation.
RLJ 5/05
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

American Dynamics RCTT16BE Installation guide

Category
Motorcycle Accessories
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI