Parameter Type Range Unit Description
Avg_CPU_Load U16 0 to 10000 0.01% Average Micro-controller load. Only available to Danfoss Power
Solutions technicians. In normal operation, “information not
available” is set true.
SPI_Flow_Cmd S16 -10000 to
10000
0.01%
Flow command received on the SPI link from the other micro-
controller.
Negative values correspond to 100% flow to the left.
Positive values correspond to 100% flow to the right.
Meas_Wheel_Angle2 S16 -10000 to
10000
0.01%
Measured wheel angle 2.
-10000 corresponds to the left most position.
0 corresponds to the neutral position.
10000 corresponds to the right most position.
SplMonTimeout_Calc U16 0 to 2550 ms
Calculated spool monitoring timeout.
SplMonTimeout_Act U16 0 to 2540 ms
Actual spool monitoring timeout.
Updated BOOL T/F ——
Pulses TRUE for one loop when new data is available.
T: Received new data.
F: Did not receive new data.
CAN_RawData ARRAY[8]U8 —— —— Data passed directly from the CAN receiver.
NoMsgReceived BOOL T/F ——
No message has been received yet from the device.
T: No message received since power on.
F: A message has been received since power on.
MsgTimedOut BOOL T/F ——
True if the time since the last status message has exceeded the
value determined by Timeout.
T: The status message has timed out, block outputs set to zero/
false. NA signals set true.
F: No error.
Avg_CPU_Load_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
SPI_Flow_Cmd_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
Meas_Wheel_Angle2_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
SplMonTimeout_Act_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
Diagnostic Signals
Enter the Checkpoints page on the second level of the PVED_CLS_STAT_MSG_6 function block to access
the signals of the function block.
Name Type Range Unit Description
Avg_CPU_Load_Rsvd
BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
Meas_Wheel_Angle2_Rsvd
BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
SPI_Flow_Cmd_Rsvd BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
User Manual
PLUS+1® Compliant PVED_CLS_STAT_MSG_6 Function Block
PVED_CLS_STAT_MSG_6 Function Block
©
Danfoss | November 2018 AQ00000266en-000101 | 7