Parameter Type Range Unit Description
STW_Stat
BOOL T/F —— Steering wheel status based on the PVED-CLS's internally monitored
disengage algorithm.
T: Steering wheel inactive.
F: Steering wheel active.
ConfCount
U16 0 to 2540 ms Confidence counter value. Internal monitored disengage confidence counter
used for "In Neutral" limit and "Disengage" limit.
SVC_Integral_Part
S16 -10000 to
10000
1 μm Integral contribution of solenoid valve control. Valid integral contribution,
where -10000 corresponds to the negative limit of the integral contribution
and 10000 corresponds to the positive limit of the integral contribution. Only
available from the primary processor.
Updated BOOL T/F ——
Pulses TRUE for one loop when new data is available.
T: Received new data.
F: Did not receive new data.
CAN_RawData ARRAY[8]U8 —— —— Data passed directly from the CAN receiver.
NoMsgReceived BOOL T/F ——
No message has been received yet from the device.
T: No message received since power on.
F: A message has been received since power on.
MsgTimedOut BOOL T/F ——
True if the time since the last status message has exceeded the value
determined by Timeout.
T: The status message has timed out, block outputs set to zero/false. NA
signals set true.
F: No error.
STW_Stat_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
SVC_Integral_Part_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
Diagnostic Signals
Enter the Checkpoints page on the second level of the PVED_CLS_STAT_MSG_8 function block to access
the signals of the function block.
The page contains checkpoints on input, parameter, and output signals. Other topics in this book
describe input, parameter, and output signals.
Name Type Range Unit Description
STW_Stat_Rsvd
BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
SVC_Integral_Part_Rsvd
BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
Status Logic
This topic describes how status logic is indicated for the function block.
The status code indicates whether the parameters used in the function are within their valid range.
Condition Hex Binary Cause Response Correction
Invalid setup
0x8008
*
1000 At least one parameter is out
of range.
Status code reported. Correct the out of range
parameters.
*
Position of set bit in a 16 bit fault or status code. Bit 1 is the least significant bit. Bit 16 set to 1 indicates a standard Danfoss status code or fault code.
User Manual
PLUS+1® Compliant PVED_CLS_STAT_MSG_8 Function Block
PVED_CLS_STAT_MSG_8 Function Block
©
Danfoss | November 2018 AQ00000268en-000101 | 7