Parameter Type Range Unit Description
BattVolt
U16 0 to 36000 mV Battery voltage.
SnsrSupplyVolt
U16 0 to 6000 mV Sensor supply voltage.
LVDT_Comp S16 -100 to 155 0.01 mm
Actual LVDT compensation value.
LVDT_Comp_Counter U8 0 to 15 ——
LVDT offset compensation counter. How many times has the LVDT offset
compensation been executed. Counter rolls over from 15 to 0.
LVDT_Comp_SplStat BOOL T/F ——
Spool control status.
T: Spool control released, ready for LVDT compensation.
F: Spool is controlled actively.
Updated BOOL T/F ——
Pulses TRUE for one loop when new data is available.
T: Received new data.
F: Did not receive new data.
CAN_RawData ARRAY[8]U8 —— —— Data passed directly from the CAN receiver.
NoMsgReceived BOOL T/F ——
No message has been received yet from the device.
T: No message received since power on.
F: A message has been received since power on.
MsgTimedOut BOOL T/F ——
True if the time since the last status message has exceeded the value
determined by Timeout.
T: The status message has timed out, block outputs set to zero/false. NA
signals set true.
F: No error.
PCB_Temp_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
BattVolt_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
SnsrSupplyVolt_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
LVDT_Comp_SplStat_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
LVDT_Comp_SplStat_Flt BOOL T/F ——
Indicates if the related signal is faulted.
T: Signal is faulted.
F: Signal ok.
Diagnostic Signals
Enter the Checkpoints page on the second level of the PVED_CLS_STAT_MSG_3 function block to access
the signals of the function block.
The page contains checkpoints on input, parameter, and output signals. Other topics in this book
describe input, parameter, and output signals.
Name Type Range Unit Description
BattVolt_Rsvd BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
PCB_Temp_Rsvd BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
SnsrSupplyVolt_Rsvd BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
User Manual
PLUS+1® Compliant PVED_CLS_STAT_MSG_3 Function Block
PVED_CLS_STAT_MSG_3 Function Block
©
Danfoss | November 2018 AQ00000263en-000101 | 7