Outputs
Learn how the outputs of the function block work.
Parameter Type Range Unit Description
Diag
Bus —— —— This bus provides diagnostic values for troubleshooting. In addition, all
inputs, parameters, and output signals are contained inside of the bus.
Status
U16 0, 0x8008 ——
This signal indicates if a parameter fault is declared. It is a bitwise code, so
multiple items can be reported at a time. The following status codes are
provided:
0x0000: No fault.
0x8008: At least one parameter is out of range.
Est_Curve S32 -803200 to
803175
0.01 1/km
Estimated curvature.
-803200: Max left.
0: Straight.
803175: Max right.
Reset_Reqd BOOL T/F ——
Request reset command status.
T: Reset required.
F: Reset not required.
PosCorrect BOOL T/F ——
Steering input position status.
T: Correct position.
F: Incorrect position.
SystemReady BOOL T/F ——
Steering system readiness.
T: System is ready.
F: System is not ready.
MechSysLockout BOOL T/F ——
Mechanical system lockout.
T: Active.
F: Not Active.
Limit_Status U8 0 to 7 ——
Guidance limit status.
0: Not limited.
1: Reserved.
2: Limited high, only lower values result in a change.
3: Limited low, only higher values result in a change.
4-5: Reserved.
6: Non-recoverable fault.
7: Reserved.
Exit_Reason U8 0 to 63 ——
Guidance exit reason.
0: No reason/all clear.
1-2: Reserved.
3: Operator override of function.
4: Reserved.
5: GMC timeout.
6: GMC out of range/invalid.
7-23: Reserved.
24: Vehicle speed too high.
25: Alternate guidance or no system active.
26-61: Reserved.
62: Error (Safe State).
63: Reserved.
Diagnostic Signals
Enter the Checkpoints page on the second level of the PVED_CLS_GMS function block to access the
function block’s signals.
The page contains checkpoints on input, parameter, and output signals. Other topics in this book
describe input, parameter, and output signals.