Parameter Type Range Unit Description
Flow_Cmd S16 -10000 to
10000
0.01%
Flow command.
IdealOilVolPerRev S16 0 to 65534 cm3 Ideal oil volume sums the total desired oil volume per revolution
before EFU, soft stop and ramps functionality is applied in the
STW/AUX algorithm.
CalcFlowStpt S16 -10000 to
10000
0.01% Flow setpoint describes the flow command before ramps and soft
stop functionality is applied in STW/AUX algorithm.
STW_AngDiff U16 0 to 36000 0.01 Deg
Steering Angle Difference. Steering wheel position difference to
ideal position in STW/AUX algorithm.
Updated BOOL T/F ——
Pulses TRUE for one loop when new data is available.
T: Received new data.
F: Did not receive new data.
CAN_RawData ARRAY[8]U8 —— —— Data passed directly from the CAN receiver.
NoMsgReceived BOOL T/F ——
No message has been received yet from the device.
T: No message received since power on.
F: A message has been received since power on.
MsgTimedOut BOOL T/F ——
True if the time since the last status message has exceeded the
value determined by Timeout.
T: The status message has timed out, block outputs set to zero/false.
NA signals set true.
F: No error.
Flow_Cmd_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
IdealOilVolPerRev_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
CalcFlowStpt_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
STW_AngDiff_NA BOOL T/F ——
Indicates if the related signal is available.
T: Signal is not available.
F: Signal available.
Diagnostic Signals
Enter the Checkpoints page on the second level of the PVED_CLS_STAT_MSG_4 function block to access
the signals of the function block.
The page contains checkpoints on input, parameter, and output signals. Other topics in this book
describe input, parameter, and output signals.
Name Type Range Unit Description
CalcFlowStpt_Rsvd
BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
FlowCmd_Rsvd
BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
STW_AngDiff_Rsvd BOOL T/F ——
Indicates if the related signal is reserved.
T: Signal is reserved.
F: Signal available.
User Manual
PLUS+1® Compliant PVED_CLS_STAT_MSG_4 Function Block
PVED_CLS_STAT_MSG_4 Function Block
©
Danfoss | November 2018 AQ00000264en-000101 | 7