ACT ACTpro MIFARE CLASSIC READERS Operating instructions

Type
Operating instructions

This manual is also suitable for

ACT ACTpro MIFARE CLASSIC READERS offer versatile solutions for access control and other applications. They support multiple output formats, including Clock & Data and Wiegand, allowing for easy integration with various systems. The readers can operate in sector, serial, or reverse serial modes, providing flexibility for different use cases. Additionally, they feature a built-in buzzer and LED indicators for user feedback. The readers are durable and weather-resistant, making them suitable for both indoor and outdoor use.

ACT ACTpro MIFARE CLASSIC READERS offer versatile solutions for access control and other applications. They support multiple output formats, including Clock & Data and Wiegand, allowing for easy integration with various systems. The readers can operate in sector, serial, or reverse serial modes, providing flexibility for different use cases. Additionally, they feature a built-in buzzer and LED indicators for user feedback. The readers are durable and weather-resistant, making them suitable for both indoor and outdoor use.

Operating & Installation Instructions for
ACTpro MIFARE Classic Readers
18-00070
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
Contents
ABOUT MIFARE CLASSIC (STANDARD)………………………………………………………………………..2
INSTALLATION NOTES…………………………………………………………………………………………….2
PRODUCT SPECIFICATION……………………………………………………………………………………….2
ORDERING INFORMATION………………………………………………………………………………………..2
READER OUTPUT DATA FORMAT………………………………………………………………………………3
WIRING INFORMATION FOR “CLOCK & DATA” OUTPUT…………………………………………………..3
WIRING INFORMATION FOR “WIEGAND” OUTPUT………………………………………………………….4
READER CONFIGURATION……………………………………………………………………………………….5
OPERATION………………………………………………………………………………………………………….5
SECTOR READER……………………………………………………………………………………………………..5
SERIAL AND REVERSE SERIAL READER
…………………………………………………………………………..5
BACKLIGHT OPERATION………………………………………………………………………………………….5
READER CONFIGURATION……………………………………………………………………………………….6
POWER ON BEEP CODES……………………………………………………………..………………………….6
READER REPROGRAMMING……………………………………………………………………………………..7
MOUNTING INSTRUCTIONS………………………………………………………………………………………8
MIFARE PANEL MOUNT INSTALLATION……………………………………………………………………………………9
1
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
About MIFARE Classic (Standard)
MIFARE Classic cards are widely used for electronic wallet (cashless vending), access control, corporate ID cards,
transportation, stadium ticketing, etc. The memory on the MIFARE Classic card is divided into sectors and blocks.
The MIFARE Classic 1K cards offers 1024 bytes of data storage, split into 16 sectors; each sector is protected by
two different keys, called A and B. ACT use the A key for read and B key for Write (this may not be the same for all
manufacturers). Each MIFARE Classic card has a unique serial number.
Important Installation Notes
On the ACTpro MIFARE 1030 ensure the grey cable is snipped and neatly tied off before applying power.
Check the correct voltage is applied to the reader
Confirm the expected Data output “Clock & Data” or “Wiegand”
Confirm the expected Reader Operation Sector, Serial or reverse serial.
Product Specification
MIFARE 1030 MIFARE 1030PM MIFARE 1040 MIFARE 1050
Description MIFARE Classic
proximity reader
MIFARE Classic
proximity reader
MIFARE Classic
proximity reader
MIFARE Classic pin
and proximity reader
Mounting Mullion Panel Surface/Flush
Proximity Yes
Pin No Yes
Outputs Clock & Data or
Wiegand 37bit, 32bit and
26bit
Yes
Selectable sector, serial &
reverse serial
Yes
Construction Robust polycarbonate housing
Potted Electronics Yes
IP Rating IP 67
Tri-Colour LED Yes
Built-in buzzer Yes
External Buzzer Control No Yes
Operating Voltage 12 - 24 Volt DC
Current Consumption (Typ) 30mA 30mA 70mA 70mA
Current Consumption (Peak) 130mA 70mA 140mA 140mA
Weight 150g 65g 142g 155g
Dimensions (H * W * D) 108 * 36 * 13 63 * 58 * 23 110 * 100 * 35 110 * 100 * 35
Operating Temperature -10 to +50 Celsius
Ordering Information
Product Code Description
ACTpro MIFARE 1030 Proximity reader, mullion mount
ACTpro MIFARE 1030PM Proximity reader, panel mount
ACTpro MIFARE 1040 Proximity reader, surface / flush mount
ACTpro MIFARE 1050 Pin & Proximity reader, surface / flush mount
2
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
Reader Output Data Format
Clock and Data
The default data output format from the ACTpro MIFARE classic readers is Clock and Data encoded as 10 BCD
digits (also known as Magnetic Stripe Track/2 or ABA).
Wiegand
The reader can be configured to output Wiegand formatted data rather that the default clock & data, by connecting
the Sense line to OV before powering on the reader, this will switch the unit to 37bit Wiegand output mode. The
reader can also be configured for 32 and 26bit Wiegand output using a programming card.
Wiring Information for “Clock & Data
” Output
The standard Clock & Data wiring colours for ACTpro MIFARE Classic readers are shown below.
Reader PIN Description Recommended wiring colour Description
Sense White Direction – connect for entry
Clock / D1 Green Clock / D1
Data / D0 Blue Data / D0
12-24 V DC Red + Voltage
0 V Black - Voltage
Red Brown Red LED
Green Yellow Green LED
Wiring for Entry / Exit “Clock and Data” Readers
Wiring for “Clock & Data” Entry Reader
Colour Controller Pin
White Sense
Green CLOCK / D1
Blue DATA / D0
Red +12V
Black 0V
Brown RED
Yellow GREEN
Wiring for “Clock & Data” Exit Reader
Colour Controller Pin
White DO NOT CONNECT
Green CLOCK / D1
Blue DATA / D0
Red +12V
Black 0V
Brown RED
Yellow GREEN
3
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
Wiring Information for “Wiegand” Output
The standard Wiegand wiring colours for ACTpro MIFARE classic readers are shown below.
Reader PIN Description Recommended wiring colour Description
Sense White Direction – connect for entry
Clock / D1 Green Clock / D1
Data / D0 Blue Data / D0
12-24 V DC Red + Voltage
0 V Black - Voltage
Red Brown Red LED
Green Yellow Green LED
Wiring for Entry / Exit “Wiegand” Readers
Wiring for “Wiegand” Entry Reader
Colour Controller Pin
White 0V
Green CLOCK / D1
Blue DATA / D0
Red +12V
Black 0V
Brown RED
Yellow GREEN
Wiring for “Wiegand” Exit Reader
Colour Controller Pin
White 0V
Green CLOCK / D1
Blue Sense
Red +12V
Black 0V
Brown RED
Yellow GREEN
4
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
Reader Configuration
Operation: ACTpro MIFARE 1030PM / 1040 / 1050
The ACTpro MIFARE readers can operate as a sector, serial or reverse serial reader. The operation of the ACTpro
MIFARE classic 1030PM, 1040 and 1050 is selectable via a jumper. The default position of the jumper is set for
sector operation (jumper on pins 1 and 2). To change the operation down power the reader, change the jumper for
the desired operation and reapply power.
Sector Serial Reverse Serial
Connect pins 1&2
Connect pins 2&3
Do NOT connect Jumper
Sector / Serial
O
p
eration Jum
p
e
r
Operation: ACTpro MIFARE 1030
The operation of the ACTpro MIFARE classic 1030 is selectable via cable configuration, the default setting is Sector
where both Orange and Purple cables are connected to 0V. To change the operation down power the reader,
change the Orange and Purple cable for the desired operation and reapply power.
Colour Sector Serial Reverse Serial
Orange 0V 0V Not Connected
Purple 0V Not Connected 0V
Sector Reader
The default sector reader operation of ACTpro MIFARE readers is to read the batch numbers that are encoded into
Sector 1 from the MIFARE cards and fobs issued by ACT. However the readers can be programmed to read any
specified sector data, this allows the readers to be installed on sites that are already using MIFARE cards. See
section on reader re-programming.
Serial and Reverse serial Reader
When in Serial or reverse serial mode the MIFARE card serial number is read by the reader.
5
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
Backlight Operation
The ACTpro MIFARE 1050 has backlight illumination of the keypad. The default operation is for the illumination to be
switched on all the time. During installation the back light operation may be switched off or changed to automatic. In
automatic mode the keypad is illuminated for 20 seconds on a key press or when a card is presented to the reader.
To change the backlight operation: Firstly power up the reader, the LED on the top right hand side will cycle through
green, blue and red and back to blue, while the LED is red enter the code below for the required operation. The code
must be completely entered while the LED is red.
Always on (Default):X014000
Always Off:X014001
Automatic:X014008
Note: the backlight operation for the ACTpro MIFARE 1030PM is controlled by jumpers marked LED.
Reader Configuration
The Internal buzzer is activated by applying 0V to the Buzz PIN. The buzzer activates 4 seconds after the 0V is
applied and sounds continuously until the 0V is removed (External Buzzer Control not available on the ACTpro
MIFARE 1030) reader.
The Red and Green LED are activated by applying 0V to the respective Red and Green input pins.
Power On Beep Codes
The Output Data Format and the Sector/Serial Operation of the reader can be determined by the beeps generated
by the reader after power is applied. The reader will generate two sets of beeps, the first indicating the Output Data
Format and the second set of beeps indicating Sector or Serial Operation. The first set of beeps will occur while the
LED is Green, the second set of beeps occur half a second later while the LED is Blue.
First Beep Set Double Beep Sector Reader
Single Beep Serial Reader
Triple Beep Serial Reader (byte reverse)
Second Beep Set Double Beep Clock & Data Output
Single Beep Wiegand 37 bit Output
Note: If the reader has been re-programmed (see next page), then a series of notes is played after the Second Beep
Set, this indicates that the default programming to read ACT MIFARE cards has been changed.
6
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
Reader Reprogramming
The ACTpro MIFARE readers will ship from the factory pre-configured to read the MIFARE cards and fobs supplied
by ACT. The ACT pro MIFARE reader can also be reconfigured for serial or reverse-serial by repositioning the
jumpers. (See section on reader configuration)
On sites with an existing installation of MIFARE cards, it may be necessary to reprogram the MIFARE readers so
that the data on the existing cards can be read. The ACTpro MIFARE readers are reprogrammed using a
programming card.
The programming card can be generated on site using the ACTWin software and an ACTpro MIFARE USB reader
(Tools->Card Manager->Mifare Card Format). You will require information on how the existing cards are encoded
before generating the programming card.
To reprogram an ACTpro MIFARE reader the programming card must be presented to the ACTpro MIFARE reader
after power up and while the LED is Red. The ACTpro MIFARE will acknowledge the re-programming by playing an
ascending note tune.
The configuration is held in non-volatile memory and so is held even if the reader is powered down. Readers that
have been reprogrammed may be reset to read ACT issued MIFARE cards and fobs with an ACT Default
Programming Card.
ACTpro MIFARE readers that have been programmed to read non ACT MIFARE cards and fobs will play a series of
ascending notes after being powered up in addition to the standard beep codes, this is to indicate that it no longer
reads the MIFARE cards and fobs issued by ACT.
Please see the "Application for an ACTpro MIFARE reader programming card" document for details on obtaining a
programming card.
7
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
Mounting Instructions
Flush Mount Unit
Surface Mount Unit
8
ACTpro MIFARE classic Operating and Installation Manual Rev 1.0
9
Installation diagram for MIFARE Panel Mount Reader
Rear view of the ACTpro MIFARE Panel Mount reader
connection to the ACTpro Door Controllers & Door Stations
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

ACT ACTpro MIFARE CLASSIC READERS Operating instructions

Type
Operating instructions
This manual is also suitable for

ACT ACTpro MIFARE CLASSIC READERS offer versatile solutions for access control and other applications. They support multiple output formats, including Clock & Data and Wiegand, allowing for easy integration with various systems. The readers can operate in sector, serial, or reverse serial modes, providing flexibility for different use cases. Additionally, they feature a built-in buzzer and LED indicators for user feedback. The readers are durable and weather-resistant, making them suitable for both indoor and outdoor use.

Ask a question and I''ll find the answer in the document