DTP Systems
Two-input Universal Twisted Pair Transmitter for
Floor Boxes
68-2985-01 Rev. A
12 20
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website,
www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di tensione non isolata pericolosa
all’interno del contenitore del prodotto che può costituire un rischio di
scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad avvertire
l’utente della presenza di importanti istruzioni di funzionamento e
manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron,
www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformoważ użytkownika o obecnożci izolowanego i niebezpiecznego
napiżcia wewnżtrz obudowy produktu, który może stanowiż zagrożenie
porażenia prżdem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzżt.
Informacji na temat wytycznych w sprawie bezpieczeżstwa, regulacji
wzajemnej zgodnożci, zgodnożż EMI/EMF, dostżpnożci i Tematy pokrewne,
zobacz Extron bezpieczeżstwa i regulacyjnego zgodnożci przewodnik, czżżż
numer 68-290-01, na stronie internetowej Extron,
www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在警告用户产品机壳内有暴露的危险 电压
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
安全記事 • 繁體中文
警告: 若產品上使用此號,是為使用者產品殼內存
可能會導致觸電之風險的未絕緣危險電
注意 產品上使用此符號,是為提醒使用設備隨附的戶手冊中有
護( )説
有關安全性指導方法規EMI/EMF 相容存取範圍和相關主題的詳細資
訊,請瀏覽 Extron 網站www.extron.com然後參閱《Extron 安全性與法規
守手準則編號 68-290-01
安全上の注意
日本語
警告: この 製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、感電の危険があるこています
意:この が製上に表示されている場合は、の取書に
されている重作と保()のについてユーザー
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項目
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) を覧ください。
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합
니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
Copyright
© 2020 Extron Electronics. All rights reserved. www.extron.com
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks (
®
), registered service marks (
SM
), and trademarks (
TM
) are the property of RGBSystems, Inc. or
ExtronElectronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(
®
)
Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, Glitch Free, Global
Configurator, GlobalScripter, GlobalViewer, Hideaway, HyperLane, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink,
MediaPort, NAV, NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, ShareLink, Show Me, SoundField, SpeedMount,
SpeedSwitch, StudioStation, SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall,
XPA, XTP, XTPSystems, and ZipClip
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RATEFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, AVEdge, CableCover, CDRS(ClassD
Ripple Suppression), Codec Connect, DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator,
DSPConfigurator, DSVP(Digital Sync Validation Processing), eLink, EQIP, Everlast, FastBite, Flex55, FOX, FOXBOX, IP Intercom HelpDesk,
MAAP, MicroDigital, Opti-Torque, PendantConnect, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), RoomAgent, Scope-Trigger, SIS,
SimpleInstructionSet, Skew-Free, SpeedNav, Triple-Action Switching, True4K, True8K, Vector™ 4K, WebShare, XTRA, and ZipCaddy
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
ATTENTION:
The Twisted Pair Extension technology works with unshielded twisted pair (UTP)
or shielded twisted pair (STP) cables; but to ensure FCC Class A and CE
compliance, STP cables and STP Connectors are required.
La technologie extension paires torsadées fonctionne avec les câbles paires
torsadées blindées(UTP) ou non blindées(STP). Afin de s’assurer de la
compatibilité entre FCC ClasseA et CE, les câbles STP et les connecteurs STP
sont nécessaires.
NOTES:
This unit was tested with shielded I/O cables on the peripheral devices. Shielded
cables must be used to ensure compliance with FCC emissions limits.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide on the Extron website.
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,0p1 scene 1,1 ^B 51 ^W^C.0
[01]
R
0004
00300
00400
00800
00600
[02]
35
[17]
[03]
E
X!
*
X1&* X2)*
X2#*
X2!
CE
}
NOTE: For commands and examples of computer or device responses used in this
guide, the character “0” is the number zero and “O” is the capital letter “o.”
Computer responses and directory paths that do not have variables are written in the font
shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping
xxx.xxx.xxx.xxx —t
SOH R
Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the
File menu, select New.
Click the
OK button.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
viiDTP2 T 202 FB • Contents
Introduction ...................................................1
About this Guide ................................................. 1
About the Switching Transmitter ......................... 1
Control Communications ................................ 2
TP Cable Advantages ......................................... 2
Features ............................................................. 3
Installation and Operation ........................... 4
Installation Overview ........................................... 4
Adapter Plates .................................................... 5
Side Panel Features ............................................ 7
Connectors and Switches Below the
Adapter Plates ............................................... 7
Connectors Above the Adapter Plates .......... 10
Top Panel Features ........................................... 11
Mounting .......................................................... 11
Ackermann GB3 (OBO Bettermann)
Floor Box ..................................................... 12
MK Electric CableLink Plus - Single Pan
Floor Box ..................................................... 12
MK Electric CableLink Plus - Modular
Floor Box ..................................................... 13
Electraplan or PUK Floor Box ....................... 13
Connection and Wiring Details .......................... 14
Power Supply Wiring .................................... 14
Serial and IR Port Connectors ....................... 16
TP Cable Termination and Recommendations 16
Operation ......................................................... 18
Indications .................................................... 18
Switch Modes............................................... 19
EDID ............................................................. 19
Reset Mode .................................................. 19
Troubleshooting — If no Image Appears ........... 19
Remote Control ...........................................20
Host Control Ports ............................................ 20
Simple Instruction Set Control .......................... 21
Host-to-Switcher Communications ............... 21
Switcher-Initiated Messages ......................... 21
Switcher Error Responses ............................ 21
Timeout ........................................................ 21
Using the Command and Response Table .... 21
Product Configuration Software Control ............ 28
Installing the Software ................................... 28
Starting the Program .................................... 31
Contents
DTP2 T 202 FB • Contents viii
DTP2 T 202 FB • Introduction 1
Introduction
About this Guide
About the Switching T
ransmitter
TP Cable Advantages
Featur
es
About this Guide
This guide describes how to install, operate, and configure the DTP2 T 202 FB, a floor
box-mounted, switching, twisted pair transmitter. The DTP2 T 202 FB outputs a signal to a
compatible DTP2 receiver, with a range of up 330 feet (100 M).
NOTE: In this guide, the DTP2 T 202 FB is commonly referred to as a “switcher,”
“transmitter,” or “switching transmitter.”
About the Switching Transmitter
The DTP2 T 202 FB is a 2-input HDMI and DisplayPort switcher with a DTP2 transmitter
output (see figure 1, on the next page). The switcher is HDCP compliant, and supports
2560x1600 @ 60 Hz and 4k/UHD @ 60 Hz signals.
The switcher selects between a DisplayPort and HDMI (or DVI video with the appropriate
adapter) inputs. The transmitter creates a proprietary digital signal consisting of one or more
of the following inputs:
The selected digital video input, including embedded digital audio
An optional analog audio input
Bidirectional RS-232 and infrared (IR) control signals
The switcher and a compatible receiver extend the usable distance of video, audio,
and control signals over a single Extron XTP DTP2 24 shielded twisted pair (STP) cable
(recommended) or Category (CAT) 5e, CAT 6, or CAT 6a STP cable.
The transmitter is compatible with all Extron DTP2 and DTP (legacy DTP) products. It has a
range of up 330 feet (100 meters).
The switcher fits into floor boxes from OBO Bettermann, MK by Honeywell, Electraplan, and
PUK.
The included external 12 VDC power supply accepts 100 to 240 VAC, 50-60 Hz to provide
worldwide power compatibility. A single power supply connected to either the transmitter or
the compatible receiver can power both units through the STP cable.
ATTENTION:
Do NOT use the transmitter to remotely power a legacy DTP receiver. Circuit
damage to the receiver WILL result.
NE PAS utiliser l’émetteur pour alimenter à distance un récepteur de la gamme
existante DTP. Cette opération FINIRA par endommager le circuit menant à le
récepteur.
DTP2 T 202 FB • Introduction 2
L
RS-232 IR
Tx Rx Tx RxG
R
POWER
12V
--A MAX
AUDIO
OUTPUTS
OVER DTP2
SIG LINK
DTP2 IN
IN1808 IPCP MA 70
INPUTS (DTP2/XTP)
LOOP OUT
31
2
5
4 6
7
SIG LINK
IN
8
SIG LINK
IN
OUTPUTS (DTP2/XTP/HDBT) AUDIO INPUTS OUTPUTS REMOTE
HDMI/CEC
OVER TP
1A 1B
SIG LINK
OUT
Tx Rx
IR
G
LAN
AV LAN 2
AV LAN 3
AV LAN 1
Tx Rx
RTS CTS
G
Tx Rx G Tx Rx G
R
1 2 3 4 G
DIGITAL I/OCOM 3COM 2COM 1
S SG G
1
1
2
2
C 3 4 C
-S G+S+V
PWR OUT = 6W
RRRRRRRRRR
R
R
R
R
R
R
R
R
R
R
R
R
R
IR/SERIAL eBUSRELAYS
100-240V 50/60 Hz
--A MAX
Tx Rx
RS-232
G
RESET
1 2
3 4
+48V
+48V
1
2
MIC/LINE
L R
AUX
3 4
AMPLIFIED OUTPUT
70V - 100W
CLASS 2 WIRING
MODEL 80
FLAT PANEL
MODEL 80
FLAT PANEL
1
WiFi
1 2 3 4
WiFi
1 2 3 4
HDMI IN
AUDIO IN
DTP2 T 202 FB
DISPLAY PORT IN
HDMI IN
AUDIO IN
HDMI
DP
SIG
HDCP
AUTO
CONFIG
RESET
OUT
Extron
IN1808 IPCP MA 70
Seamless
Presentation
Scaler
Extron
DTP2 R 211
Receiver
Extron
DTP T HWP
4K 331 D
Transmitter
Extron
TLP Pro 1025T
Tabletop
Touchpanel
Extron
FF 220T
Plenum 2' x 2' Flat Field
Ceiling Speakers
Ethernet
HDMI
DisplayPort HDMI
HDMI
HDMI
4K Display
4K Display
PC PC
4K Media Player
Extron
DTP2 T 202 FB
Transmitter
CATx Cable
up to 330' (100 m)
CATx Cable
up to 330' (100 m)
CATx Cable
up to 330' (100 m)
AV
LAN
Ethernet
RS-232
AV
LAN
Audio
Handheld
Microphones
Figure 1. Typical Switching Transmitter Application
The switching transmitters are controlled by Simple Instruction Set (SIS) commands (see
Simple Instruction Set Control on page 21) and the Extron Product Configuration
Software (see Product Configuration Software on page 28).
Control Communications
The RS-232 and IR communications are passive pass-through only. The receiver and
transmitter do not generate or respond to the RS-232 and IR communication signals.
HDCP, EDID and CEC are negotiated from source to sink, with the receiver and transmitter
transparent during the exchange.
TP Cable Advantages
Twisted pair cable is much smaller, lighter, more flexible, and less expensive than coaxial
or HDMI cable. These receiver and transmitter twisted pair (TP) products make cable runs
simpler and less cumbersome. Termination of the cable with RJ-45 connectors is simple,
quick, and economical.
NOTE: Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the receiver and transmitter. DTP2 and legacy DTP receivers and
transmitters do not work properly with these cables.
DTP2 T 202 FB • Introduction 3
Features
Transmits HDMI or DisplayPort video, control, and analog audio up to 330
feet (100 meters) over a single STP cable — The unit provides high reliability and
maximum performance on an economical and easily installed cable infrastructure.
HDBaseT compatible — The DTP2 output can be configured to send video and
embedded audio, plus bidirectional RS-232 and IR signals to an HDBaseT-enabled
display.
Supports computer video to 2560x1600 @ 60 Hz or UHD (3840x2160) @ 60 Hz.
Analog stereo audio embedding — Analog stereo audio signals can be selectively
embedded onto the digital video output signal and transported over the TP cable. The
HDMI and DisplayPort inputs can be set to pass the embedded digital audio, embed
the analog audio, or to automatically embed the analog audio when no digital audio is
detected.
Accepts additional analog stereo audio signals — The DTP2 transmitter supports
a direct pass through connection for stereo analog audio signals for simultaneous
transmission over the same single TP cable. Analog audio is embedded onto the digital
video signal. A DTP2 or legacy DTP receiver can output balanced and unbalanced
audio, allowing streamlined integration within an AV system.
Bidir
ectional RS-232 and IR insertion for AV device control — Control and IR
signals can be transmitted alongside the video signal over the TP cable, allowing the
remote device to be controlled without the need for additional cabling. Bidirectional
control insertion eliminates the need for control system wiring to remote devices.
Remote powering of transmitter or r
eceiver — For simplified installation, only one
power supply is necessary to power both devices.
Digital conversion of analog input signals
— Analog signals are digitized, ensuring
that a reliable, high quality digital video signal is sent to the output destination.
EDID Minder
— Automatically manages EDID communication between connected
devices, ensuring that all sources power up properly and reliably output content for
display.
Key Minder
— Authenticates and maintains continuous HDCP encryption between
input and output devices, verifying HDCP compliance for quick, reliable switching in
professional AV environments.
Compatible with all DTP2 and legacy DTP r
eceivers — The switching transmitters
can be used with the Extron IN1608, DTP CrossPoint 84, and other DTP-enabled
products to meet application requirements.
DTP2 T 202 FB • Installation and Operation 4
Installation and
Operation
This section contains information for mounting, connecting, wiring, and operating the
DTP2 T 202 FB switching transmitter. Topics in this section include:
Installation Overview
Adapter Plates
Side Panel Featur
es
T
op Panel Features
Mounting
Operation
T
roubleshooting — If No Image Appears
Installation Overview
The DTP2 T 202 FB is to be installed in an Ackermann GB3 (OBO Bettermann), MK Electric
CableLink Plus Modular, MK Electric CableLink Plus Single Pan, Electraplan, or PUK floor box.
CAUTION: Failure to check the items listed below may result in personal injury or
property damage.
ATTENTION : La non-vérification des éléments listés ci-dessous peut provoquer des
blessures ou dommages matériels.
1. Check that the installation of the floor box meets government, building, electrical, and
safety codes.
2. Install the floor box according to the instructions of the manufacturer.
3. Prepare and pull the cables through the floor box.
TIP: Secure cables with clamps or ties to provide strain relief.
4. Trim back and insulate shields with heat shrink.
ATTENTION:
To prevent short circuits, the outer foil shield can be cut back to the point
where the cable exits the cable clamp. Both braided and foil shields should be
connected to an equipment ground at the other end of the cable.
Afin d’éviter les court circuits, le blindage en aluminium extérieur peut être
réduit jusqu’à ce que le câble sorte de la cosse de câble. Le blindage tressé et
le blindage en aluminium devraient être connectés à la masse d’un équipement
à l’autre bout du câble.
5. Install the appropriate adapters to the desired position in the floor box (see Adapter
Plates on page 5).
DTP2 T 202 FB • Installation and Operation 5
6. Connect cables to the side panel connectors located below the adapter plates (see
Connectors and Switches Below the Adapter Plates on page 7).
7. Mount the DTP2 T 202 FB to the floor box (see Mounting on page 11).
8. Connect appropriate devices to the remaining side connectors (see Connectors
Above the Adapter Plates on page 10) and top panel connectors (see Top Panel
Features on page 11).
9. Configure the DTP2 T 202 FB with SIS commands (see Simple Instruction
Set Control on page 21) or the Product Configuration Software (see Product
Configuration Software on page 28).
Adapter Plates
Each model of floor box requires a specific pair of provided adapter plates to secure the
device to the box (see the table below for the appropriate adapter plates to use with specific
floor boxes).
Floor Box Adapter Plate Example
Ackermann GB3 (OBO Bettermann) 995241
995242
MK Electric CableLink Plus Single Pan 995243
MK Electric CableLink Plus Modular 995244
Electraplan 995300
PUK 995300
NOTE: The 995242 adapter plate is only used for position 2 of the Ackermann GB3
(OBO Bettermann) floor box.
1. Determine the position in the floor box to install the DTP2 T 202 FB. Each compatible
floor box contains three positions to install devices (see figure 2 on the next page).
NOTE: For the MK Electric CableLink Plus Single Pan floor box, do not use
position 2.
DTP2 T 202 FB • Installation and Operation 6
OBO Bettermann
GESR7 Floorbox Assembly
1
2
3
Figure 2. Example of Positions in a Floor Box
(Ackermann GB3 [OBO Bettermann] Shown)
2.
Insert the top flange of the adapter plate into a mounting slot that is no higher than the
thir
d slot from the top (see figure 3).
Figure 3. Installing an Adapter Plate (995241 Shown) into a Mounting Slot
NOTES:
Install adapter plates in
mounting slots of the same
position in the floor box.
The MK Electric
CableLink Plus Single Pan
floor box does not have
mounting slots. Use a
mounting screw to secure
the large mounting hole of
the 995243 adapter plate
to the mounting hole of the
floor box position
(see figure 4).
MK Electric
CableLink Plus
Single Pan Floor Box
995243
995243
Figure 4. Installing 995243 Adapter Plates
DTP2 T 202 FB • Installation and Operation 7
3. Rotate the adapter plate down so the bottom flange rests against the wall of the floor
box (see figure 5).
Figure 5. Fixing the Adapter Plate (995241 Shown) in Place
4.
If the desir
ed position is position 2 of the Ackermann GB3 (OBO Bettermann) floor box,
use the provided screws to secure the 995242 adapter plate to a 995241 adapter plate
(see figure 6).
Figure 6. Installing the 995242 Adapter Plate to a 995241 Adapter Plate
Side Panel Features
Connectors and Switches Below the Adapter Plates
OVER TP
OUT
IR RS-232
RS-232
REMOTE
POWER
SEND POWER
12V
1.4A MAX
OFFHDBT DTP
GRxTxRxTxGRx Tx
LINK
SIG
e
DTP2 T 202 FB
HDMI IN
HDMI
DP
SIGNAL
HDCP
AUTO
CONFIG
AUDIO IN
DISPLAYPORT IN
RESET
OVER TP
OUT
IR RS-232
RS-232
REMOTE
POWER
SEND POWER
12V
1.4A MAX
OFF HDBT DTP
G Rx Tx Rx Tx G Rx Tx
LINK
SIG
Side Panel
A
B
C
D
D
E
F
Figure 7. Side Panel Connectors and Switches Below the Adapter Plates
A
Power connector (see page 8)
D
TP connector (see page 9)
B
Remote RS-232 port
E
Send Power switch
C
Over TP RS-232/IR port
F
TP function switch
DTP2 T 202 FB • Installation and Operation 8
A
Power connector (see figure 7 on the previous page) — Plug the included
+-
1.4A MAX
12V
POWER
external 12 VDC power supply into this 2-pole connector (see Power supply
wiring on page 14 to wire the connector).
— or —
Supply power to the receiver (see the appropriate user guide, available at
www.extron.com) and leave the switches as described in the NOTES below.
ATTENTION:
The DTP2 device is configured to output power to DTP2 models only.
If connected to a legacy DTP device, set the Send Power toggle switch
(item
E
on page 9) to the O position (right). Failure to turn the power off
will damage the connected legacy DTP device.
L
’appareil DTP2 est configuré pour fournir une alimentation aux modèles
DTP2 uniquement. S’il est connecté à un modèle DTP traditionnel, veuillez
positionner l’interrupteur à bascule Send Power (
E
) sur « Off » (droite).
Si l’interrupteur n’est pas positionné sur off, vous risquez d’entraîner la
défaillance de l’appareil DTP connecté.
NOTES:
When the following switches are set as follows, one power supply can
power both units:
Send Power switch (item
E
) is in the Send position.
TP function switch (item
F
) is in the DTP2 position.
When either switch is not as described, the transmitter and receiver each
require a local 12 VDC power supply.
B
Remote RS-232 port — Plug a host device into the switching transmitter via
TxRxG
RS-232
REMOTE
the 3.5 mm, 3-pole captive screw connector for remote control of the
transmitter (see Serial and IR port connectors on page 16 to wire the
connector).
9600 Baud 8 data bits
No parity 1 stop bit
C
Over TP RS-232 and IR port — Plug a serial RS-232 signal,
a
IR RS-232
Rx RxGTx Tx
OVER TP
modulated IR signal (up to 40 kHz), or both into this 3.5 mm, 5-pole direct
insertion connector for bidirectional RS-232 and IR communication (see
Serial and IR port connectors to wire the connector). RS-232 and IR
data can be transmitted simultaneously.
DTP2 T 202 FB • Installation and Operation 9
D
TP connector (see figure 7 on page 7) — Plug one end of an STP cable
LINK SIG
OUT
to this RJ-45 female jack. Plug the opposite end of this cable into the DTP2
Input RJ-45 connector on a compatible receiver (see TP cable
termination and recommendations on page 16 to properly wire the
RJ-45 connector and for detailed NOTES).
Signal LED indicator — Lights green when the transmitter outputs a video signal.
Link LED indicator — Lights yellow when XTP devices are connected and
communication is established.
ATTENTION:
Do NOT use the transmitter to remotely power a legacy DTP receiver. Circuit
damage to the transmitter WILL result.
NE P
AS utiliser le l’émetteur pour alimenter à distance un récepteur de la
gamme existante DTP. Cette opération FINIRA par endommager le circuit
menant à le récepteur .
Do not connect this connector to a computer data or telecommunications
network.
Ne c
onnectez pas ces port à des données informatiques ou à un réseau de
télécommunications.
E
Send Power toggle switch — In a system with a DTP2 receiver, set
SEND POWEROFF
the toggle switch to the Send Power position (left) on the powered unit to
enable sending power to the unpowered unit. Set the toggle switch to the Off position
(right) on the DTP2 unit that is to receive power.
F
TP function switch
DT
ATTENTION:
Position this switch BEFORE connecting the appropriate device to the TP
connector. Failure to comply can damage the endpoint.
Positionnez le sélecteur AVANT de connecter l’appareil approprié au
connecteur TP. Ne pas respecter cette procédure pourrait endommager le
point de connexion.
If the connected receiving device is in the Extron DTP2 series, set this switch to the
DTP position (right). For an HDBaseT-enabled receiver type, set this switch to the HDBT
position (left). This switch tailors the output signal as follows:
HDBT position — The TP output consists of HDMI with embedded audio plus
RS-232 and IR.
DTP2 position — The TP output consists of HDMI with embedded audio, analog
audio, RS-232 and IR, and remote power.
NOTES:
When the switch is in the HDBT position, the transmitter and receiver each
requires a local 12 VDC power supply.
When the switch is in the DTP2 position, one 12 VDC power supply,
connected to either the transmitter or the receiver, can power both units so
long as both are DTP2 and the Send Power switch on one of the units is in the
Send Power position and Send Power on the other unit is in the O position.
DTP2 T 202 FB • Installation and Operation 10
Connectors Above the Adapter Plates
OVER TP
OUT
IR RS-232
RS-232
REMOTE
POWER
SEND POWER
12V
1.4A MAX
OFF HDBT DTP
GRxTxRxTxGRx Tx
LINK
SIG
C
A
B
A
Input port 1 (HDMI)
B
Audio input port
C
Input port 2 (DisplayPort) (see page 11)
Figure 8. Side Panel Connectors Above the Adapter Plates
A
Input 1 (HDMI) port — Plug a digital video input into this HDMI port. It
accepts HDMI video or (DVI with an adapter). The transmitter also accepts
embedded digital audio on this connector. See HDMI Connector on page 18
to use an Extron LockIt lacing bracket to secure the HDMI connector to the device.
NOTE: The maximum HDMI cable length is 15 feet (4.5 m).
B
Audio In connector — If desired, plug an analog audio source into the transmitter
via this 3.5 mm tip-ring-sleeve (TRS) jack. Both video inputs can share this audio
input.
NOTES:
See figure 9 to identify the connector tip, ring,
and sleeve when you are making connections
for the switching transmitter from existing
audio cables. A mono audio connector
consists of the tip and sleeve. A stereo audio
connector consists of the tip, ring, and sleeve.
The analog audio can be assigned to a
specific input or set to be always output
(see Assign analog audio SIS command on
page 22).
Sleeve ( )
Ring (
-
)
Tip (+)
3.5 mm Stereo Plug Connector
(balanced)
Figure 9. TRS Connector
Wiring
By default, audio input is selected automatically. When the HDMI input is selected with
automatic audio input selection, the transmitter prioritizes embedded digital audio. The
following table shows the audio format that is sent over the DTP2 connection when a
specific audio format is not specified.
Selected
Video Input
Embedded Audio
Present
Analog Audio
Present
Audio Sent Over
TP Cable
DisplayPort N/A Yes Analog audio
DisplayPort N/A No No audio
HDMI Yes No HDMI embedded audio
HDMI Yes Yes HDMI embedded audio
HDMI No Yes Analog audio
HDMI No No No audio
C
Input 2 (DisplayPort) port — Plug a digital video input into this DisplayPort
connector. The transmitter also accepts embedded digital audio on this
connector.
DTP2 T 202 FB • Installation and Operation 11
Top Panel Features
w
DTP2 T 202 FB
HDMI IN
AUDIO IN DISPLAYPORT IN
HDMI
DP
SIGNAL
HDCP
AUTO
CONFIGRESET
A
B
Figure 10. Top Panel Features
A
Config(uration) port — Connect a host
CONFIG
device to the top panel mini USB B
configuration port. This port serves a similar
communications function as the side panel
Remote RS-232 port, but it is easier to access
than the side port after the switcher has been
installed and cabled.
NOTE: A top panel Configuration port
connection and a side panel Remote
RS-232 port connection can both be active
at the same time. If commands are sent
simultaneously to both, the command that
reaches the processor first is handled first.
B
Reset button — Initiates two levels of
RESET
switcher reset. For the different reset levels,
press and hold the button while the
switcher is running or while you power up the
switcher (see Reset Mode on page 19 for
details).
Mounting
Before mounting the floor box, consider the mounting location and prepare the surface as
necessary.
1. If not already completed, install the appropriate adapter plates in the desired position
and mounting slots (see Adapter Plates on page 5).
2. Align the screw holes on the DTP2 T 202 FB with the screw holes on the adapter
plates.
3. Using the provided self-threading screws and washers, secure the DTP2 T 202 FB to
the adapter plates (see figure 11 though figure 14 beginning on page 12).
DTP2 T 202 FB • Installation and Operation 12
Ackermann GB3 (OBO Bettermann) Floor Box
DTP T 202 FB
POWER
DTP T FB 332
REMOTE
RS-232
-
+
G
Rx
Tx
12V
A MAX
XTP OUT
995242
995241
Figure 11. Mounting the Unit into an Ackermann GB3 (OBO Bettermann) Floor Box
NOTE: Position 2 requires the installation of the 995242 adapter plate on top of one of
the 995241 adapter plates.
MK Electric CableLink Plus - Single Pan Floor Box
DTP T 202 FB
POWER
DTP T FB 332
REMOTE
R
S-232
- +
G
Rx
T
x
12V
A
MA
X
XT
P
O
WE
R
DTP T FB 332
R
EMOT
E
R
S
-2
3
2
12V
A MA
X
995243
995243
Figure 12. Mounting the Unit into an MK Electric CableLink Plus - Single Pan
Floor Box
ATTENTION:
Do not install the DTP2 T 202 FB in position 2 (see figure 2 on page 6).
Ne pas installer le DTP2 T 202 FB en position 2 (voir l’illustration2 sur la page6).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Extron DTP2 T 202 FB User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages