1. SAFETYPRECAUTIONS
•The“SAFETYPRECAUTIONS”indicatedinthemanualcontainimpor-
tantinformationpertainingtoyoursafety.Besuretoobservethem.
•Fordetailsoftheoperationmethod,refertotheoperatingmanual.
•Requesttheusertokeepthemanualonhandforfutureuse,suchasfor
relocatingorrepairingtheunit.
WARNING
Indicatesapotentiallyorimminentlyhazardoussitu-
ationwhich,ifnotavoided,couldresultindeathor
seriousinjury.
Installationofthisproductmustbedonebyexperiencedservicetechni-
ciansorprofessionalinstallersonlyinaccordancewiththismanual.
Installationbynonprofessionalorimproperinstallationoftheproduct
maycauseseriousaccidentssuchasinjury,waterleakage,electric
shock,orre.Iftheproductisinstalledindisregardoftheinstructionsin
thismanual,itwillvoidthemanufacturer’swarranty.
Installationmustbeperformedinaccordancewithregulations,codes,
orstandardsforelectricalwiringandequipmentineachcountry,region,
ortheinstallingplace.
Donotoperatethisunitwhenyourhandsarewet.Touchingtheunitwith
wethandswillcauseanelectricshock.
Whenchildrencanapproachtheunitortouchtheunit,takepreventive
measures.
Disposeofthepackingmaterialssafely.Tearanddisposeoftheplastic
packingbagssothatchildrencannotplaywiththem.Thereisthedan-
gerofsuffocationifchildrenplaywiththeoriginalplasticbags.
CAUTION
Indicatesapotentiallyhazardoussituationthatmay
resultinminorormoderateinjuryordamageto
property.
Whendetectingtheroomtemperatureusingtheremotecontroller,
pleasesetuptheremotecontrolleraccordingtothefollowingconditions.
Iftheremotecontrollerisnotwellset,thecorrectroomtemperaturewill
notbedetected,andthustheabnormalconditionslike“notcool”or“not
heat”willoccureveniftheair-conditionerisrunningnormally.:
•Alocationwithanaveragetemperaturefortheroombeingaircondi-
tioned.
•Locatewhereisnotbeaffectedbyinowofoutsideairsuchascaused
byopeningandclosingadoor.
•Notdirectlyexposedtotheoutletairfromtheairconditioner.
•Outofdirectsunlight.
•Awayfromtheinuenceofotherheatsources.
REMOTE CONTROLLER
(WIRED TYPE)
INSTALLATION MANUAL
PARTNo.9373328407
Forauthorizedservicepersonnelonly.
Installationbyendusersornotqualiedpersonscancauseharmto
personalsafety,cancauseseveredamagetobuildingandproduct,can
leadtoimproperfunctionorreducedlifetimeoftheequipment.
Donotinstalltheunitinthefollowingareas:
•Donotinstalltheunitnearasourceofheat,steam,orammablegas.
Otherwise,recouldresult.
•Arealledwithmineraloilorcontainingalargeamountofsplashedoil
orsteam,suchasakitchen.Itwilldeteriorateplasticparts,causingthe
partstofall.
•Areacontainingequipmentthatgenerateselectromagneticinterfer-
ence.Itwillcausethecontrolsystemtomalfunction,andcauseer-
roneousoperation.
•Installtheunitinawell-ventilatedplaceavoidingrainsanddirectsun-
light.
Donottouchtheswitcheswithsharpobjects.Doingsowillcauseinjury,
trouble,orelectricshock.
Donotexposethisunitdirectlytowater.Doingsowillcausetrouble,
electricshock,orheating.
Donotsetvesselscontainingaliquidonthisunit.Doingsowillcause
heating,re,orelectricshock.
2. MAINUNITANDACCESSORIES
Thefollowinginstallationpartsaresupplied.Usethemasrequired.
Nameandshape Q’ty Nameandshape Q’ty
Wiredremotecontroller
1
CD-ROM
1
Installationmanual
(Thismanual)
1
Screw(M4×16mm)
Forinstallingtheremote
controller
2
Operatingmanual
1
Cabletie
Forremotecontrollerand
remotecontrollercable
binding
1
3. ELECTRICALREQUIREMENT
Whenconnectingtheremotecontrollerusethefollowingwiring.
Cablesize Wiretype Remarks
22to16AWG
(0.33to1.25mm²)
Nonpolar
2core
Usesheathed
twistedpaircable
18AWG
Thermostatcable
2core
Usesheathednon
twistedpaircable
Selectaexiblecablethatcanbeboundusingcabletiesfromoverthe
cablesheathinsidethisunit.
Maximumconnectablenumberofremotecontrollersbycablesizeandthe
length.
Cablesize
Max.connectablenumberof
remotecontrollers
AWG mm²
L*≤328ft
(L*≤100m)
328ft<L*
≤820ft
(101m<L*
≤250m)
820ft<L*
≤1,640ft
(251m<L*
≤500m)
VRF RAC VRF RAC VRF RAC
16 1.25 4 2 4 2 4 2
18 0.75(1.25>S*≥0.75) 4 2 4 2 2 2
20 0.5(0.75>S*≥0.5) 4 2 2 2 2 2
22 0.3(0.5>S*≥0.3) 4 2 1 1 1 1
*L:Totalcablelength,*S:Cablesize
Français
Español
English
CONTENTS
1. SAFETYPRECAUTIONS.........................................................................1
2. MAINUNITANDACCESSORIES............................................................1
3. ELECTRICALREQUIREMENT................................................................1
4. SELECTINGANINSTALLATIONLOCATION..........................................2
5. INSTALLINGTHEREMOTECONTROLLER...........................................3
6. SETTINGTHEREMOTECONTROLLER................................................5
7. TESTRUN..............................................................................................10
8. ERRORCODES.....................................................................................10
9373328407-01_IM.indb 1 2/22/2017 11:06:13 AM
En-2
4. SELECTINGANINSTALLATION
LOCATION
4.1. DimensionsandNameofparts
Remotecontrollerunit
Unit:in(mm)
Hole:3/8×3/16
(9×4.5)
Hole:1/4×3/16
(6×4.5)
Hole:1/2×3/16
(12.5×4.5)
13/16(20.4)
(a) (b) (c) (d)
4-3/4(120)
1-3/16(30)
1-5/16(33)
7/8
(
23
)
5/8(15.3)
3-5/16(83.5)
4-4/3(120)
1-13/16(45.3)
2-1/2(63.5)
(a) Roomtemperaturesensor(inside)
(b) Operation(Ocupied/Unoccupied)
button:
Itispossibletooperateonlywhile
displayingtheMonitorMode
screen.
(c) LEDlamp(Operationindicator)
(d) Touchpaneldisplay
AllFujitsuGeneralproductsare
manufacturedtometricunits
andtolerances.UnitedStates
customaryunitsareprovidedfor
referenceonly.
Incaseswhereexact
dimensionsandtolerancesare
required,alwaysrefertometric
units.
Monitormodescreen
Thehomescreenofthisunit.Except
forinthefollowingcases,thescreen
willreturntothisscreenifthereisno
operationforover10min.(Unsaved
settingswillbecancelled.)
•InEmergencyStop.
•InTransferringdata.
•Incheckingtheindoorunitposition
•InFunctionSetting
•InVacation
76°F
80°F
74°F
84°F
68°F
Away
Custom
Auto
Auto
Cool
Heat
Office
Set Temp.
Mode
MenuStatus
Vacation
Fan
Fri 10:00AM
Room Temp.
Cool
Heat
Override
Occupied
(n)
(c)
(f)
(n)
(e)
(i)
(h)
(g)
(d)(a) (n)(m)
(n) (j)(k)(l)
(b)
(a) R.C.Groupname:Referto6.3.4.
(b) Clock:Referto6.2.4.
(c) Mode:Settheoperationmode.Refertooperatingmanual.
(d) SetTemp.:Settheoperatingtemperature.Refertooperatingmanual.
(e) Fan:Setthefunspeed.Refertooperatingmanual.
(f) Away:When“Away”isenabled,thestarttemperatureof“Away”opera-
tionisdisplayedwhenunoccupied.When“away”isoperating,“Away
Operation”isdisplayed.Refertooperatingmanual.
(g) Roomtemperature:Referto4.2.and6.3.5.
(h) Override:Displayedwhilethefollowingfunctionsareoperating:
•AutoOffTimer
•SetTemp.AutoReturn
Refertooperatingmanual.
(i) Occupiedstate:“Occupied”or“Unoccupied”isdisplayedaccordingto
theoperationofOperationbuttonorschedulesetting.
Inthefollowingcases,theoperationbuttonneedstobepressedtwice:
•Whenstoppingtheoperatingindoorunitwhile“Unoccupied”is
displayed,presstheoperationbuttononcetosetto“Occupied”and
pressitagaintosetto“Unoccupied.Thentheindoorunitstops.
•Whenoperatingthestoppedindoorunitwhile“Occupied”isdisplayed,
presstheoperationbuttononcetosetto“Unoccupied”andpressit
againtosetto“Occupied”.Thentheindoorunitoperates.
Inthefollowingcases,theoccupiedstatedoesnotswitchto“Occupied”
eveniftheindoorunitstartsoperation:
•Antifreezeoperation
•Awayoperation
•Optimumstartoperation
(j) Menu:Setthevarioussettings.
(k) Status:Checkthestatusofindoorunitanderror.
(l) Vacation:Whenthisistouched,thescheduleisdisabledandthe
indoorunitremainsunoccupied.“Vacation”isdisplayedonlywhena
scheduleisset.Refertooperatingmanual.
(m)“CustomAutoMode”or“Away”doesnotwork.
Verifythefollowingsettings:
•R.C.SensorSetting:Referto6.3.5.
•MasterIndoorUnitSetting:Referto6.3.6.
Whentheremotecontrollerthatusesasensorischangedinthemas-
terindoorunitorR.C.Group,changetheoperationmodeordisable
“Away”.
(n) Statusicons:Refertooperatingmanual.
ForthescreendisplayotherthanChinese,thisproductusesaBitmap
fontmadeanddevelopedbyRicohCompany,Ltd.
4.2. Settingtheroomtemperaturedetection
location
CAUTION
Asthetemperaturesensorofremotecontrollerdetectsthetemperature
nearthewall,whenthereisacertaindifferencebetweentheroom
temperatureandthewalltemperature,thesensorwillnotdetectthe
roomtemperaturecorrectlysometimes.Especiallywhentheouterside
ofthewallonwhichthesensorispositionedisexposedtotheopenair,
itisrecommendedtousethetemperaturesensoroftheindoorunitto
detecttheroomtemperaturewhentheindoorandoutdoortemperature
differenceissignicant.
Thedetectionlocationoftheroomtempera-
turecanbeselectedfromthefollowing2
methods.Choosethedetectionlocationthat
isbestfortheinstallationlocation.
Thetemperaturesensoroftheindoorunitor
theremotecontrollercanbeusedtodetect
theroomtemperature.
Asensoroftheindoor
unit(inside)
Asensoroftheremote
controller(inside)
Whentheremotecontrollerisnotused,thefollowingfunctionscannot
beused.
•[CustomAuto]oftheoperationmodes:Refertooperatingmanual.
•[AwaySetting]:Refertooperatingmanual.
4.3. Installationspace
•Donotembedthisremotecontrollerinawall.
•Recommendationinstallationheightoftheremotecontrolleris55in(1.4
m)(fromtheoorsurfacetothebottomoftheremotecontroller).
•Evenwhenyouinstallaremote
controllertooneofaswitchbox
andthesurfaceofawall,secure
thespaceshowninfollowing
gure.Whenthereisinsufcient
space,theremayberemotecon-
trollersensormisdetectionsand
remotecontrollerremovalmaybe
difcult.
2(30)or
more
Unit:in(mm)
9(220)
ormore*
2(30)
ormore
2(30)
ormore
*Pleasesecureenoughspacewhereaat-bladescrewdrivertotakeoffa
casecanbeinserted.
9373328407-01_IM.indb 2 2/22/2017 11:06:14 AM
En-3
5. INSTALLINGTHEREMOTE
CONTROLLER
WARNING
Alwaysusetheaccessoriesandspeciedinstallationworkparts.Check
thestateoftheinstallationparts.Notusingthespeciedpartswillcause
unitstofalloff,waterleakage,electricshock,re,etc.
Installataplacethatcanwithstandtheweightoftheunitandinstall
rmlysothattheunitwillnottoppleorfall.
Wheninstallingthisunit,makesurethattherearenochildrennearby.
Otherwise,injuryorelectricshockcouldresult.
Beforestartinginstallationwork,turnoffthepowerofthisunitandthe
connectiondestination.Donotturnonthepoweragainuntilinstallation
iscompleted.Otherwise,itwillcauseelectricshockorre.
Usetheaccessoriesorspeciedconnectioncables.Donotmodifycon-
nectioncablesotherthanthosespecied,donotuseextensioncords,
anddonotuseindependentbranchwiring.Theallowablecurrentwillbe
exceededandcauseelectricshockorre.
Installtheremotecontrollercablessecurelytotheterminalblock.Con-
rmthatexternalforceisnotappliedtothecable.Useremotecontroller
cablesmadeofthespeciedwire.Ifintermediateconnectionorinser-
tionxingareimperfect,itwillcauseelectricshock,re,etc.
Whenconnectingtheremotecontrollercable,routethecablessothat
therearcaseofthisunitissecurelyxed.Iftherearcaseisimperfectly
xed,itmaycausereoroverheatingoftheterminals.
Performfunctionalearthingworkpositively.Donotconnectthefunc-
tionalearthingwiretoatelephoneearth(Ground)wire,waterpipe,or
conductorrod.
Alwaysfastentheoutsidecoveringoftheconnectioncablewiththe
cabletie.Iftheinsulatorischafed,electricdischargemayoccur.
CAUTION
DonotsettheDIPswitchorrotaryswitchofthisunitexceptasspecied
inthismanualortheoperatingmanualsuppliedwiththeairconditioner.
Settingtheswitchesotherthanspeciedwillcauseanaccidentor
trouble.
Beforeopeningthecaseofthisunit,completelydischargestaticelec-
tricitychargedonyoubody.Notdoingsowillcausetrouble.
Donottouchthecircuitboardandcircuitboardpartsdirectlywithyour
hands.Otherwise,injuryorelectricshockcouldresult.
Becarefulsothatthefrontcasedoesnotfallafterthefrontcasescrews
areremoved.Otherwise,injurycouldresult.
Installtheremotecontrollercables1mawayfromtelevisionandradio
toavoiddistortedimagesandnoise.
Conrmthenameofeachterminalblockoftheunitandconnectthe
wiringinaccordancewiththedirectionsgiveninthemanual.Improper
wiringworkwilldamagetheelectricpartsandcausesmokeandre.
Connecttheconnectorssecurely.Looseconnectorswillcausetrouble,
heating,re,orelectricshock.
Neverbundletheremotecontrollercables,thepowersupplycableand
transmissioncabletogether.Bundlingthesecablestogetherwillcause
missoperation.
Wheninstallingtheconnectioncablenearasourceofelectromagnetic
waves,useshieldedcable.Otherwise,abreakdownormalfunction
couldresult.
5.1. Wiringtypes
5.1.1. Singlecontrol
Remotecontroller
Indoorunit
5.1.2. Groupcontrol
Withasingleremotecontroller,upto16unitscanbesimultaneouslyoper-
ated.
Indoorunit0 Indoorunit1 Indoorunit2 Indoorunit3
Remotecontroller
5.1.3. Multipleremotecontrol
Numberofconnectableremotecontrollers.VRF:4,RAC:2
Multipleinstallationmethoddescribedaboveisprohibitedtocombine3
Wiredtypewith2WiredType.
Inmultipleinstallations,thefollowingfunctionsarerestricted.
FunctionsthatcanonlybeusedwithaMasterRemoteController:
•AutoOffTimerSetting*1
•WeeklyTimerSetting*1
•SetTemp.AutoReturn*1
•6.3.11OptimumStartSetting
•6.4.7I.U.AddressVerication
•6.4.8FunctionSetting
(*1:RefertoOperatingmanual)
Indoorunit
Remote
controller
(Master)
Remote
controller
(Slave)
Groupcontrolandmultipleremotecontrolcanbeusedtogether.
5.2. PreparingforInstallation
5.2.1. Stripoftheremotecontrollercable
Sheathedcable
A:1/4in(7mm)
B:1/4in(7mm)
A B
5.2.2. Removethefrontcase
Whenopeningtheremotecontroller,removetheconnectorfromthe
frontcase.Thecablesmaybreakiftheconnectorisnotremovedand
thefrontcasehangsdown.Wheninstallingthefrontcase,connectthe
connectortothefrontcase.Whenremovingandconnectingtheconnec-
tor,becarefulnottobreakthecables.
Releasetheclaws(2places)withaat-bladescrewdriver,andseparate
thefrontcaseandrearcase.
Lightlyliftthe
frontcase.
Flat-blade
screwdriver
Claws(2places)
Rearcase
Frontcase
Disconnecttheconnectioncableconnectorfromtheconnectorofthefront
casePCboard(printedcircuitboard).
Frontcase
(backside)
Rear
case
Connector
9373328407-01_IM.indb 3 2/22/2017 11:06:15 AM
En-4
5.2.3. SettingtheDIPswitch
CAUTION
UseaninsulatedscrewdrivertosettheDIPswitches.Donottouchthe
DIPswitchwithyourhands.
Frontcase(backside)
SettheDIPswitchtoON
OFF ON
ON
Beforeusingthisproduct,alwayssetDIPswitchto“ON”.Ifnotset,when
themainpoweristurnedonagain,thesetdatabymenuoperationwillbe
erasedandcauseerroneousoperation.
[DIPSwitch]
•Performstheenabling/disablingofthebackupfunctionbytheinternal
battery.
•Itisdisabledwhenshippedfromthefactorytopreventconsumptionof
thecharge.
5.3. Installation
CAUTION
Performwiringsothatwaterdoesnotenterthisunitalongtheexternal
wiring.Alwaysinstallatraptothewiringortakeothercountermeasures.
Otherwiseitwillcausetroubleorelectricshockorre.
5.3.1. Installtherearcase
A.Whenattachingtoswitchbox:
Sealthewiringholeoftheremotecontroller
cablewithputty.
Trap(remotecontrollercable)
Connector
Rearcase
Screws
Box
Putty
Trap
B.Whenattachingtothewalldirectly:
Sealthewiringholeoftheremotecontroller
cablewithputty.
Trap(remotecontrollercable)
Connector
Rearcase
Screws
Wall
Putty
Trap
C.Whenroutingthecableon-wall:
Rearcase
Epoxyputty
Cablecover
(morethan
1mmthick)
Cutoff
5.3.2. Connectingtheremotecontrollercable
CAUTION
Whenconnectingaremotecontrollercabletotheremotecontroller
terminalblock,pleaseusethespeciedtorquetotightenscrews.Ifyou
over-tightenscrews,theywillbreaktheterminalunit.
Becarefultoavoidbreakingthecablebyover-tighteningthecabletie.
Tighteningtorque 7.1to10.6lbf•in(0.8to1.2N•m)
Fastentheoutsidecoveringoftheconnectioncablewiththecabletie.
Tightenthecabletiermlysothatpullingforcedoesnotpropagatetothe
terminalconnectionevenifforceof30Nisappliedtothecable.
Selectaexiblecablethatcanbeboundusingcabletiesfromoverthe
cablesheathinsidethisunit.
Cabletie
GOOD
PROHIBITED
5.3.3. Attachthefrontcase
Connecttheremotecontrollercableconnectorto
theconnectorofthefrontcasePCboard.Insert
afteradjustingupperpartoffrontcase.Otherwise,
thereisariskofdamagetotheinternalpartsofthis
unit.Whenyouattachthefrontcase,makesurethat
thecablesarenotbeingpinchedbyfrontcase.
5.4. Connectingtotheindoorunit
CAUTION
Whenconnectingtheremotecontrollercabletotheindoorunit,donot
connectittotheoutdoorunitorthepowerterminalblock.Itmaycausea
failure.
WhenswitchingtheDIPswitch(SW1)ontheindoorunitPCboard,be
suretoturnoffthepowersupplytotheindoorunit.Otherwise,thePC
boardoftheindoorunitmaybedamaged.
Thereare2methodstoconnecttheremotecontrollercabletotheindoor
unit.Oneistheconnectionusingconnectingcable(Includedintheindoor
unit),andtheotheristheconnectiontheremotecontrollercableiscon-
nectedtotheexclusiveterminalblockoftheindoorunit.
(Forthedetails,refertotheinstallationmanualoftheindoorunittobe
used.)
5.4.1. Whenconnectingtotheconnector
(1) Useatooltocutofftheterminalontheendoftheremotecontroller
cable,andthenremovetheinsulationfromthecutendofthecableas
showninFig.1.Connecttheremotecontrollercableandconnecting
cableasshowninFig.2.Besuretoinsulatetheconnectionbetween
thecables.
Remotecontrol-
lercable(Non-
polar)
Insulated
connection
White
Black
13/16in
(20mm)
Red
Connecting
cable
Cutand
terminate
Fig.1 Fig.2
(2) Connecttheremotecontrollercabletotheconnectingcable,and
insertittotheconnector.Setto“2WIRE”theDIPswitch(SW1)onthe
PCboardoftheindoorunit.
(1)
(2)
9373328407-01_IM.indb 4 2/22/2017 11:06:16 AM
En-5
*LayoutofConnectorandPC
boardisvaries,depending
onthetypeofindoorunit.
Setto"2WIRE"the
DIPswitch(SW1)
Indoorunit
PCboard
Connector
(adapter)
Remotecontroller
cable(Non-polar)
Connectingcable
ConnectorCNC01
(onboard)
SW1
Indoorunit
PCboard
5.4.2. Whenconnectingtoexclusiveterminalblock
(1) Connecttheendofremotecontrollercabledirectlytotheexclusive
terminalblock.Setto“2WIRE”theDIPswitch(SW1)onthePCB
(printedcircuitboard)oftheindoorunit.
*Layoutofterminalblockand
PCboardisvaries,depend-
ingonthetypeofindoorunit.
Terminalblock
Remotecontroller
cable(Non-polar)
Setto"2WIRE"the
DIPswitch(SW1)
Indoorunit
PCboard
Tighteningtorque
M3screw
(Remotecontroller/Y1,Y2)
4.4to5.3lbf·in
(0.5to0.6N·m)
For“Groupcontrol”or“Multipleremotecontrol,refertothefollowing
gureonhowtoconnecttotheindoorunitterminal.
GOOD PROHIBITED
Diameterofcables
aredifferent
Connectthecables
to1side
6. SETTINGTHEREMOTECONTROLLER
6.1. Initializationprocedure
Afterremotecontrollerinstallationworkiscomplete,performinitialization
usingthefollowingproceduresbeforestartingtousethesystem.
(*:Itemsthatindoorunitdoesnotsupportarenotdisplayed.)
Turnonthe
power
Settingofrst
timestart
Initialsetting
Initializationend
OtherSettings
Afterinstallingthisunit,performthetestruntoconrmthattheunitis
operatingproperly.Then,explaintheoperationofthisunittothecus-
tomer.
6.2. Settingofrsttimestart
6.2.1. Turnonthepower
CAUTION
Recheckthewiring.Incorrectwiringwillcausetrouble.
Wheninitiallystartingupthisunit,thefollowingsettingscreenwillbe
displayed.Settingsconguredatthisstagecanbechangedafterwards.
Ifanerrorscreenisdisplayed,shutdownall
unitpower,andchecktheconnections.After
resolvingtheproblem,turnonthepower
again.
Error
Code 01
If“Pleasesettheaddresscorrectly.”is
displayed,touch[Close],andthe“RCAd-
dressSetting”screen(referto6.4.6)willbe
displayed.Aftersetting,pleaserestartthis
unit.
Error (code:XX.X)
Please set the address correctly.
Close
6.2.2. LanguageSetting
1.
The“LanguageSetting”screenhastwopages.Youcanswitchbe-
tweenthepagesbytouching[NextPage]or[PreviousPage].Touch
thelanguagetobeused.
Touch[OK]to
displaythe“R.C.
Master/Slave
Setting”screen.
Deutsch Español
Ё᭛ Français
Język
polski
Language Setting
Page 1/ 2
Cancel
OK
Next
Page
English
Language Setting
Page 2/ 2
Cancel
OK
Русский
Previous
Page
Português Türkçe
Italiano Ελληνικά
Dutch
6.2.3. R.C.Master/SlaveSetting
1.
(a) Iftheremotecontrollerisasingle
connection,thissettingisomitted.Pro-
ceedto“6.2.4.DataandTimeSetting”.
(b) Ifaremotecontrollerhasmultiplecon-
nections,andif“Master”isinitiallyset,
allotherunitswillbesetto“Slave”.
R.C. Master / Slave Setting
Cancel OK
Master
Slave
PleasesetonlyoneMasterremotecontroller.UnitsotherthanMas-
teraresettoSlaveautomatically.
Whenremotecontrollersaresetto“Slave”,settingitemswillbe
restricted.
Touch[OK]todisplaythe“DateandTimeSetting”screen.
6.2.4. DateandTimeSetting
1.
Touchthe[Date]onthe“DateandTimeSetting”screen.The“Date”
screenisdisplayed.
2.
Touch[
]or[ ]tosettheyear,month,anddate.Touch[OK]to
returntothe“DateandTimeSetting”screen.
3.
Touchthe[Time]onthe“DateandTimeSetting”screen.The“Time”
screenisdisplayed.
1. 2. 3.
Date and Time Setting
Date
01/ 01/2017
Time
12:00 AM
Sun 12:00AM
Cancel OK
Date Format Day/Month/Year
Time Format 12:00-11:59AM/PM
Summer Time Setting Disable
2017
0101
Sun 12:00AM
Date
Cancel OK
YearMonthDay
Date and Time Setting
Date
01/ 01/2017
Time
12:00 AM
Sun 12:00AM
Cancel OK
Date Format Day/Month/Year
Time Format 12:00-11:59AM/PM
Summer Time Setting Disable
6.2.1. Turnonthepower......................................5
6.2.2. LanguageSetting....................................... 5
6.2.3. R.C.Master/SlaveSetting......................... 5
6.2.4. DateandTimeSetting............................... 5
6.2.5. Temp.UnitSetting...................................... 6
6.2.6. PasswordDefaultSetting.......................... 6
6.3.4. R.C.GroupNameSetting.......................... 7
6.3.5. RCSensorSetting*....................................7
6.3.6. MasterIndoorUnitSetting......................... 7
6.3.7.
PasswordSetting(administratorpassword)..
7
6.3.8. DisplayItemSetting................................... 7
6.3.10. DeadbandSetting...................................... 8
6.3.11. OptimumStartSetting................................ 8
6.3.12. I.U.DisplayNumberSetting*.....................8
6.4.1. ErrorHistory...............................................8
6.4.2. SettingStatusList...................................... 8
6.4.3. FilterSignReset*....................................... 8
6.4.4. Version....................................................... 9
6.4.5. TestRun..................................................... 9
6.4.6. R.C.AddressSetting.................................. 9
6.4.7. I.U.AddressVerication............................. 9
6.4.8. FunctionSetting......................................... 9
6.4.9. InstallerPasswordChange...................... 10
6.4.10. Initialization.............................................. 10
9373328407-01_IM.indb 5 2/22/2017 11:06:18 AM
En-6
4.
Touch[
]or[ ]tosethours,minutes,andAM/PM.Touch[OK]to
returntothe“DateandTimeSetting”screen.
5.
Touch[OK]onthe“DateandTimeSetting”screentodisplaythe
Temp.UnitSetting”screen.
4. 5.
12 00
Sun 12:00AM
Time
Cancel OK
hour
AM
min.
Date and Time Setting
Date
01/ 01/2017
Time
12:00 AM
Sun 12:00AM
Cancel OK
Date Format Day/Month/Year
Time Format 12:00-11:59AM/PM
Summer Time Setting Disable
6.2.5. Temp.UnitSetting
1.
Selectandtouch[°F]or[°C]andtouch
[OK].
°C
°F
Temp. Unit Setting
Cancel OK
2.
Touch[OK]onthe“Temp.UnitSetting”
screentodisplaythe“PasswordDefault
Setting”screen.
6.2.6. PasswordDefaultSetting
1.
Selectandtouch[Enable]or[Disable]and
touch[OK].
Theinitialvalueat“ChangeSetting”
of“6.3.7PasswordSetting”isdifferent
dependingontheselectionofcommercial
useorresidentialuse.Refertothetable
below.
Password Default Setting
Cancel OK
Enable
Disable
(For Commercial Use)
(For Residential Use)
Function
(*:Itemsthatindoorunitdoesnot
supportarenotdisplayed.)
Enable
(Commercial)
Disable
(Residential)
AutoOffTimer On Off
WeeklyTimer On Off
SetTemp.AutoReturn On Off
SetTemp.RangeSetting On Off
AntiFreeze* On Off
AwaySetting On Off
HumanSensorSetting* On Off
FanControlforEnergySaving* On Off
InitialSetting On Off
Maintenance On Off
2.
Wheninitialstart-upsettingiscomplete,
thescreenontherightwillbedisplayed.
Thisscreenisthe“Monitormodescreen”,
whichisthehomescreenofthisunit.
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
Unoccupied
6.3. Initialsetting
Conguresettingsrequiredatthetimeofinstallation.
Thisunithastwokindsofpasswords;pass-
wordforadministratorsandpasswordfor
installers.Passwordforadministratorscannot
beusedforthesettingsrelatedtotheinstalla-
tionofthisunit.Installerpasswordcanbeused
tocongureallofsettingforthisunit.
0
CL
5
1
6
2
7
3
8
4
9
Cancel OK
Password Verification
Enter Current Password
When“Password(InstallerPassword)Verication”screenisdisplayed,
enterthepassword(installerpassword)andtouch[OK].Thedefault
passwordis“0000”(4digits).
1.
Touchthe[Menu]onthe“MonitorModescreen”.The“MainMenu”
screenisdisplayed.
2.
The“MainMenu”screenhastwopages.Touch[NextPage]or[Pre-
viousPage]toswitchbetweenscreens.Touchthe[InitialSetting].
(Itemsthatindoorunitdoesnotsupportarenotdisplayed.)
1. 2.
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
Unoccupied
Monitor
Next
Page
Page 1/ 2
Main Manu
Air Flow Direction
Setting
Weekly Timer
Setting
Auto Off Timer
Setting
Special Setting
Monitor
Previous
Page
Page 2/ 2
Main Menu
Summer Time
Setting
Initial Setting Maintenance
Preference
3.
The“InitialSetting”screenhasthreepages.Touch[NextPage]or
[PreviousPage]toswitchbetweenscreens.Touchtheitemsyou
wishtocongure.
(Itemsthatindoorunitdoesnotsupportarenotdisplayed.)
Back
Next
Page
Page 1/ 3
Initial Setting
Language Setting Date Setting
R.C.Group
Name Setting
Temp. Unit
Setting
Back
Previous
Page
Page 2/ 3
Initial Setting
R.C. Sensor
Setting
Password Setting
Display Item
Setting
Master Indoor
Unit Setting
Next
Page
Back
Previous
Page
Page 3/ 3
Initial Setting
RC Master/
Slave Setting
I.U. Display
Number Setting
Deadband Setting
Optimum Start
Setting
6.3.1. LanguageSetting
Touchthe[LanguageSetting]onthe“InitialSetting”screen.The“Lan-
guageSetting”screenisdisplayed.
Forthemethodofsettinglanguage,referto6.2.2.LanguageSetting.
Selectthelanguagetobeused,andtouch[OK]on“LanguageSetting”to
returntothe“InitialSetting”screen.
6.3.2. DateSetting
1.
Touchthe[DateSetting]onthe“InitialSet-
ting”screen.The“DateSetting”screenis
displayed.
Selectandtouch“DateandTimeSetting”
or“DisplayFormatSetting”.
Date Setting
Date and Time Setting
Display Format Setting
Back
Whensettingsforallitemsarecomplete,thescreenwillreturntothe
homescreen.Touch[Back]toreturntothe“InitialSetting”screen.
•DateandTimeSetting
Touchthe[DateandTimeSetting]onthe“DateSetting”screen.The“Date
andTimeSetting”screenisdisplayed.
Forthemethodofconguration,referto6.2.4.DateandTimeSetting.Set
allrequireditems,andtouch[OK]onthe“DateandTimeSetting”screen
toreturntothe“DateSetting”screen.
•DisplayFormatSetting
1.
Touchthe[DateFormat]onthe“DisplayFormatSetting”screen.
The“DateFormat”screenisdisplayed.
2.
Selectandtouchthedatadisplayformat.Touch[OK]onthe“Date
Format”screentoreturntothe“DisplayFormatSetting”screen.
3.
Touchthe[TimeFormat]onthe“DisplayFormatSetting”screen.
The“TimeFormat”screenisdisplayed.
1. 2. 3.
Display Format Setting
Cancel OK
Fri 10:00AM
Date Format
Time Format
Day/Month/Year
12:00–11:59AM/PM
Month/Dat/Year
Year/Month/Day
Date Format
Cancel OK
Day/Month/Year
Fri 10:00AM
Display Format Setting
Cancel OK
Fri 10:00AM
Date Format
Time Format
Day/Month/Year
12:00–11:59AM/PM
4.
Selectandtouchthedatadisplayformat.Touch[OK]onthe“Time
Format”toreturntothe“DisplayFormatSetting”screen.
5.
Touch[OK]onthe“DisplayFormatSetting”screentoreturntothe
DateSetting”screen.
4. 5.
00:00–11:59 AM/PM
00:00–23:59
Time Format
Cancel OK
12:00–11:59 AM/PM
Fri 10:00AM
Display Format Setting
Cancel OK
Fri 10:00AM
Date Format
Time Format
Day/Month/Year
12:00–11:59AM/PM
6.3.3. Temp.UnitSetting
Touchthe[Temp.UnitSetting]onthe“InitialSetting”screen.The“Temp.
UnitSetting”screenisdisplayed.
Forhowtocongure,referto6.2.5.Temp.UnitSetting.Settemperature
unitsandtouch[OK]onthe“Temp.UnitSetting”toreturntothe“Initial
Setting”screen.
9373328407-01_IM.indb 6 2/22/2017 11:06:20 AM
En-7
6.3.4. R.C.GroupNameSetting
Touchthe[R.C.GroupNameSetting]onthe“InitialSetting”screen.The
R.C.GroupNameSetting”screenisdisplayed.
•Aboutthe“R.C.GroupNameSetting”screen
Touchtherelevantkeyandentera
name.Touch[OK]toreturntothe
“InitialSetting”screenafterdis-
playingthe“Conrmationscreen”.
R.C.Group Name Setting
Cancel OK
Fixed
Phrase
UVW
XY
Z./
_–
ABC
DE
ABCDEFGHIJKLM│ Over
FGH
IJ
KLM
NO
0–9
SP BS
PQR
ST
(a)
(b)
(d)
(e)
(f)
(c)
(a) Inputarea:Ifthenumberofinputcharactersexceedsthatpermitted,
“Over”willbedisplayedontherightside.
(b) Characterkeys:Touchthesamekeyuntilthecharacteryouwishto
useisdisplayed.
(c) FixedPhrasekey:Floor,Corridor,Ofce,ConfRoom,ReceptRoom,
Room,RoomNo.,Front,Side,Entrance,Outlet,East,West,South,
North,Windowareregistered.Touchthe[FixedPhrase]keyuntilthe
sentenceyouwishtouseisdisplayed.
(d) Spacekey
(e) Backspacekey
(f) Cursorkeys
6.3.5. RCSensorSetting
1.
Touchthe[RCSensorSetting]onthe
“InitialSetting”screen.The“RCSensor
Setting”screenisdisplayed.
Ifaremote-controlsensorisused,touch
[Used].Touch[OK]toreturntothe“Initial
Setting”screen.
R.C. Sensor Setting
Cancel OK
Used
Not Used
Whensetto[NotUsed]bythissetting,thefollowingfunctionscannot
beused:(RefertotheoperatingmanualontheaccessoryCD-ROM.)
•CustomAutointheoperationmode.Referto[2CONTROL]→[2-2
OperationSettings]→[2-2-1SettheOperationMode].
•AwaySetting.Referto[3SETTING]→[3-5SpecialSetting]→[3-5-5
AwaySetting].
•OptimumStartSetting.Referto[3SETTING]→[3-8InitialSetting]→
[3-8-9OptimumStartSetting].
6.3.6. MasterIndoorUnitSetting
•Oneofthemultipleindoorunitsconnectedtothesamerefrigerantsys-
temorRBunitcanbesetasthe“masterunit”.
•Theindoorunitdenedasthe“masterunit”determinestheprioritymode
(coolorheat)withintherefrigerantsystemorRBgroup.
•SwitchsettingontheoutdoorunitorRBunitthatisconnectedtothe
indoorunits.RefertotheinstallationmanualofoutdoorunitorRBunit.
1.
Touchthe[MasterIndoorUnitSetting]onthe“InitialSetting”
screen.The“MasterIndoorUnitSetting”screenisdisplayed.
TosetaunitastheMasterIndoorUnit,touch[Set].
2.
Touch[Yes]whentheconrmationscreenisdisplayedtoreturnto
the“MasterIndoorUnitSetting”screen.
1. 2.
Master Indoor Unit Setting
Back Set
Master Indoor Unit Setting
Not Master Indoor Unit
No Yes
Master Indoor Unit Setting
The connected indoor unit will be
set as the master indoor unit. OK?
WhenchangingtheMasterIndoorUnit,anotherindoorunitcannotbe
madethemasterindoorunitunlessthesettingsofthecurrentmaster
indoorunitarecancelledbeforehand.
(“Reset”cannotbeperformedwhiletheindoorunitisoperating.)
6.3.7. PasswordSetting(administratorpassword)
Setorchangetheadministratorpassword.
1.
Touchthe[PasswordSetting]onthe“InitialSetting”screen.The
PasswordSetting”screenisdisplayed.
Thentouchthe[ChangePassword]onthe“PasswordSetting”
screen.The“ChangePassword”screenisdisplayed.
2.
Enterthecurrentpassword,thentouchthe[OK].
Thedefaultpasswordis“0000”(4digits).
3.
Enterthenewpassword,thentouchthe[OK].Itreturnstothe
PasswordSetting”screen.
1. 2. 3.
Password Setting
Change Password
Change Setting
Back
0
CL
5
1
6
2
7
3
8
4
9
Cancel OK
Password Verification
Enter Current Password
0
CL
5
1
6
2
7
3
8
4
9
Cancel OK
Change Password
Enter New Password
4.
Touchthe[ChangeSetting]onthe
PasswordSetting”screen.The“Change
Setting”screenisdisplayed.
Password Setting
Change Password
Change Setting
Back
5.
The“ChangeSetting”screenis3or4
pages,theycanbeswitchedbythe[Previ-
ousPage]or[NextPage].Itemssettobe
[On]requiretheadministratorpasswordto
openthesettingscreen.
Auto Off Timer [Off]
[On]
[On]
Weekly Timer
Set Temp. Auto Return
Change Setting
Page 1/ 4
Cancel
OK
Next
Page
Set Temp. Range Setting [On]
[On]
[On]
Anti Freeze
Away Setting
Change Setting
Page 2/ 4
Cancel
OK
Next
Page
Previous
Page
Human Sensor Setting [On]
[On]
[On]
Fan Control for Energy Saving
Initial Setting
Change Setting
Page 3/ 4
Cancel
OK
Next
Page
Previous
Page
Maintenance [On]
Change Setting
Page 4/ 4
Cancel
OK
Previous
Page
Itemsthatindoorunitdoesnotsupportarenotdisplayed.
6.
Touchtherelevantitemtodisplaythesettingscreen.Touch[OK]
aftertouching[On]toreturntothe“ChangeSetting”screen.Touch
[OK]onthe“ChangeSetting”screenaftersettingrelevantitemsto
returntothepasswordsettingscreen.
7.
Touchthe[Back]onthe“PasswordSetting”.Itreturnstothe“Initial
Setting”screen.
6. 7.
Auto Off Timer
Cancel OK
On
Off
Password Setting
Change Password
Change Setting
Back
6.3.8. DisplayItemSetting
•FilterSign
Setto“Visible”todisplayiconsonthe“Monitormodescreen”duringthe
indoorunitltercleaningperiod.
1.
Touchthe[DisplayItemSetting]onthe“InitialSetting”screen.The
DisplayItemSetting”screenisdisplayed.
Thentouchthe[FilterSign]onthe“DisplayItemSetting”screen.
The“FilterSign”screenisdisplayed.
2.
Touch[OK]aftertouching[Visible]or[Invisible]toreturntothe
DisplayItemSetting”screen.
1. 2.
Filter Sign [Visible]
Display Item Setting
Cancel OK
Room Temp. [Invisible]
Filter Sign
Cancel OK
Visible
Invisible
9373328407-01_IM.indb 7 2/22/2017 11:06:22 AM
En-8
•RoomTemp.
Setto“Visible”todisplaytheroomtemperaturedetectedbythisuniton
themonitorscreen.
3.
Touchthe[RoomTemp.]onthe“DisplayItemSetting”screen.The
RoomTemp.”screenisdisplayed.
4.
Touch[OK]aftertouching[Visible]or[Invisible]toreturntothe
DisplayItemSetting”screen.
5.
Touchthe[OK]onthe“DisplayItemSetting”.Itreturnstothe“Initial
Setting”screen.
3. 4. 5.
Filter Sign [Visible]
Display Item Setting
Cancel OK
Room Temp. [Invisible]
Room Temp.
Cancel OK
Visible
Invisible
Filter Sign [Visible]
Display Item Setting
Cancel OK
Room Temp. [Visible]
6.3.9. RCMaster/SlaveSetting
Ifmultipleremotecontrollersaresetforaremote-controlgrouporfor
asingleindoorunit,itisnecessarytosettheremote-controllermaster.
Thissettingwillberequiredatthetimeofinitialstart-upduringinstalla-
tion.However,thissettingcanbechangedafterwards.Nomasterremote
controllerswillbeautomaticallysettobeslaves.Thefollowingfunctions
canbeusedwithslaveremotecontrollers.
Forthemethodofconguration,referto6.2.3.RCMasterSlaveSetting.
Setting.Touch[OK]onthe“RCMaster/SlaveSetting”screenaftersetting
thetemperatureunitstoreturntothe“Initialsetting”screen.
Donotperform“RCMaster/SlaveSetting”duringsettingoroperating
fromtheMasterunit.
6.3.10. DeadbandSetting
1.
Touchthe[DeadbandSetting]onthe“Initial
Setting”screen.The“DeadbandSetting”
screenisdisplayed.
DeadbandSetting”screenisdisplayed.
Adjustthedeadbandwiththe[
]or[ ].
5
°F
Deadband Setting
Cancel OK
Whenthe[OK]istouched,thedisplayreturnstothe“InitialSetting”
screen.
Whenthe"Automodetype"(No.68)ofthefunctionsettingonthein-
doorunitissetto"Dualsetpoint",deadbandcannotbesetonthisunit.
(TheDeadbandSettingisnotdisplayed.)Pleasesetinthe"Deadband
value"(No.69)ofthefunctionsettingontheindoorunit.
6.3.11.OptimumStartSetting
1.
Touchthe[OptimumStartSetting]onthe
“InitialSetting”screen.“OptimumStart
Setting”screenisdisplayed.Selectthe
[On]or[Off].
Whenthe[OK]istouched,thedisplay
returnstothe“InitialSetting”screen.
Optimum Start Setting
Cancel OK
On
Off
6.3.12. I.U.DisplayNumberSetting
Atinitialstarting,thedisplaynumbers(UnitX)oftheindoorunitsdisplayed
atthe“IndividualVTHold”settingofthisremotecontrollerareautomati-
callyallocatedinascendingorderofaddressvalue.(Fortheindoorunit
displaynumber(UnitX),referto“3-2-3IndividualVTHold”oftheoperat-
ingmanualontheaccessoryCD-ROM)
Theindoorunits(correspondingaddresses)canberearrangedinarbitrary
orderinwhichyouwanttocorrespondtothedisplaynumber(UnitX)at
thissetting.Decidetheindoorunit(address)correspondingtothedisplay
number(UnitX)byconsultingtheuser.
1.
Touchthe[I.U.DisplayNumberSetting]onthe“InitialSetting”
screen.
2.
“I.U.DisplayNumberSetting”screenisdisplayed.Whenthescreen
hasmultiplepages,theycanbeswitchedbytouchingthe[Next
Page]or[PreviousPage].Theaddress(System-Unit)allocatedto
thecurrentdisplaynumber(UnitX)isdisplayed.Therefrigeration
systemaddress(Ref.-in.)isdisplayedonlywhenthisremotecon-
trollerisconnectedtoaVRFsystem.Touchthedisplaynumbers
(UnitX)whoseaddressyouwanttointerchange.
3.
Theaddressselectionscreenisdisplayed.Selecttheaddressof
theindoorunityouwanttomatchtothedisplaynumberselectedat
step2with[
]or[ ].
When[OK]istouched,thedisplayreturnstothescreenof2and
theaddressisinterchangedwiththeselecteddisplaynumber(Unit
X).Repeatsteps2and3uptothedesiredorder.
When[Back]ofthescreenof2istouched,thedisplayreturnstothe
“InitialSetting”screen.
2. 3.
/
/
002–01
002–02
002–03
/
01–01
01–02
01–03
Unit 1
Unit 2
Unit 3
Back
Next
Page
Page 1/ 6
I.U. Display Number Setting
Disp No. System–Unit
/
Ref.–In.
/
002–02
/
002–03
/
002–04
/
002–01
01–02
01–03
01–04
01–01
I.U. Display Number Setting
Cancel OK
Page 1/ 4
Disp No. System–Unit
/
Ref.–In.
Unit 1
Unit 2
Unit 3
Unit 4
6.4. Maintenance(OtherSettings)
Carryoutthefollowingsettingandconrmation,asrequired.
1.
Touchthe[Menu]onthe“Monitormodescreen”.The“MainMenu”
screenisdisplayed.
2.
The“MainMenu”screenhastwopages.Touch[NextPage]or[Pre-
viousPage]toswitchbetweenscreens.Thentouchthe[Mainte-
nance].
(Itemsthatindoorunitdoesnotsupportarenotdisplayed.)
1. 2.
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
Unoccupied
Monitor
Next
Page
Page 1/ 2
Main Manu
Air Flow Direction
Setting
Weekly Timer
Setting
Auto Off Timer
Setting
Special Setting
Monitor
Previous
Page
Page 2/ 2
Main Menu
Summer Time
Setting
Initial Setting Maintenance
Preference
3.
The“Maintenance”screenisdisplayed.The“Maintenance”screen
has3pages.Touch[NextPage]or[PreviousPage]toswitchbe-
tweenscreens.
(Itemsthatindoorunitdoesnotsupportarenotdisplayed.)
Back
Next
Page
Page 1/ 3
Maintenance
Error History
Setting
Status List
Version
Filter Sign
Reset
Previous
Page
Back
Next
Page
Page 2/ 3
Maintenance
Test Run
R.C. Address
Setting
Function Setting
I.U. Address
Verification
Back
Previous
Page
Page 3/ 3
Maintenance
Initialization
Installer Password
Change
6.4.1. ErrorHistory
1.
Touchthe[ErrorHistory]onthe“Maintenance”screen.The“Error
History”screenisdisplayed.
Ifthereare7ormoreerrors,youcanswitchbetweenpagesby
touching[NextPage]or[PreviousPage]Uptoamaximumof32er-
rorscanbesaved.Oncetherearemorethan32errors,theoldest
onewillbedeleted.
Touch[Back]toreturntothe“Maintenance”screen.
2.
Todeletetheerrorhistory,touch[EraseAll]andthen[Yes]onthe
conrmationscreen.
1. 2.
11:00
2:53
8:53
11:00
11:00
11:00
1
2015/ 8/ 1 002-01 141
2
2015/ 7/30 002-02 143
3
2015/ 7/25 002-02 143
4
2015/ 7/22 002-01 141
5
2015/ 7/22 002-01 141
6
2015/ 7/21 002-01 141
Page 1/ 2
Error History
No. Date Time Address Code
Back
Next
Page
Erase
All
AM
AM
AM
AM
AM
AM
Delete entire error history?
Error History
No Yes
6.4.2. SettingStatusList
1.
Touchthe[SettingStatusList]onthe
Maintenance”screen.The“SettingStatus
List”screenisdisplayed.
Touch[NextPage]or[PreviousPage]to
switchbetweenscreens.
Touch[Back]toreturntothe“Maintenance”
screen.
Auto Off Timer
– Operation Stop Time
– Time Range
Weekly Timer
Set Temp. Auto Return
– Cool/Dry
– Heat
[Disable]
[30min.]
[ – ]
[Disable]
[Disable]
[60min. / 84°
F
]
[60min. / 74°
F
]
Back
Next
Page
Page 1/ 4
Setting Status List
6.4.3. FilterSignReset
1.
Touchthe[FilterSignReset]onthe“Main-
tenance”screen.The“FilterSignReset”
screenisdisplayed.
Touch[OK]toresettheltersign,and
returntothe“Maintenance”screen.
Cancel OK
Filter Sign Reset
The filter sign will be reset. OK?
9373328407-01_IM.indb 8 2/22/2017 11:06:24 AM
En-9
6.4.4. Version
1.
Touchthe[Version]onthe“Maintenance”
screen.The“Version”screenisdisplayed.
Touch[Back]toreturntothe“Maintenance”
screen.
E000V00P00L00
Version
Back
6.4.5. TestRun
Carryoutatestrunaftercompletingconguration.
1.
Touchthe[TestRun]onthe“Maintenance”
screen.The“TestRun”screenisdis-
played.
Touch[OK]toreturntothe“Maintenance”
screen,andstartthetestrun.Thetestrun
willautomaticallyendinapproximately60
min.
Cancel OK
Test Run
The test run will be performed. OK?
Whentestrunisendedmidway,returntothe“MonitorMode”screen
andchecktheoccupiedstate.When“Occupied”isdisplayed,pressthe
operationbuttontosetto“Unoccupied.Thentestrunisended.When
Unoccupied”isdisplayed,presstheoperationbuttononcetosetto
“Occupied”andpressitagaintosetto“Unoccupied.Thentestrunis
ended.
6.4.6. R.C.AddressSetting
Addresseswillbeautomaticallysetwheninitiallystartingupthisunit.In
suchacase,donotchangetheremotecontrolleraddressfortheindoor
unit,andkeepitattheinitialsettingof0.
•Checkingtheremotecontrolleraddress
1.
Touchthe[R.C.AddressSetting]onthe
Maintenance”screen.The“R.C.Address
Setting”screenisdisplayed.
The“CurrentAddress”isdisplayedas
[System-Unit].Thevaluefor“Unit”refers
totheremotecontrolleraddress.
[001–01]
R.C.Address Setting
Current Address
Back
Manual Addressing
Address Reset
Touch[Back]toreturntothe“Maintenance”screen.
Whentheaddressissetmanually,this
markisdisplayed.
•ManualAddressSetting
Onlysetaddressesmanuallywhenusingdifferentnumbersfor
addresses.
Aremote-controlleraddressfortheindoorunitneedstobeset.
Settheremote-controladdressesfortheindoorunitswhichare
connectedusingthesameremote-controlcablewitharangefrom1to
9andfromA(10)toF(15),withoutanyduplicates.(Donotuse“0”for
conguration.)
Forhowtoconguretheremotecontroladdressesfortheindoorunit,
refertoitsworkmanual.
1.
Touchthe[RCAddressSetting]onthe“Maintenance”screen.The
R.C.AddressSetting”screenisdisplayed.
Touchthe[ManualAddressing].The“ManualAddressing”screenis
displayed.
2.
Touch[
]or[ ]tosettheaddressesofthisunit.Touch[OK]to
displaytheconrmationscreen,andtouch[Yes]toreturntotheRC
Addresssettingscreen.
Ifyouwishtocarryoutcongurationagain,touch[AddressReset]
onthe“R.C.AddressSetting”.
1. 2.
[001–01]
R.C.Address Setting
Current Address
Back
Manual Addressing
Address Reset
01001
Manual Addressing
Cancel OK
System Unit
Theaddressforthisunitcanbesetfrom1to32.However,donotset
thesamenumberasthatfortheremote-controladdressofanindoor
unitconnectedusingthesameremote-controlcable.
6.4.7. I.U.AddressVerication
Checktheaddressandpositionoftheindoorunit.
1.
Touchthe[I.U.AddressVerication]onthe“Maintenance”screen.
The“I.U.AddressVerication”screenisdisplayed.
Iftherearemultiplepages,youcanswitchbetweenthembytouch-
ing[NextPage]or[PreviousPage].
Touch[Check]todisplaytheindoorunitaddresscheckingstart
screen.
2.
Touch[Yes]todisplaytheconrmationscreen.
3.
Selecttheindoorunittobechecked.Iftherearemultiplepages,
youcanswitchbetweenthembytouching[NextPage]or[Previ-
ousPage].Theselectedindoorunitwillstarttoblowairandasha
LED*.(*Onlywhentheindoorunithastherelevantfunctions)
Touch[Back]ontheconrmationscreentoreturntotheprevious
screen.
1. 2. 3.
1
002–01 01–01
/
002–02 01–02
/
2
002–03 01–03
/
3
002–04 01–04
/
4
002–05 01–05
/
5
002–06 01–06
/
6
/
Page 1/ 2
I.U. Address Verification
No. System–Unit Ref.–In.
Back
Check
Next
Page
No Yes
I.U. Address Verification
Indoor unit position will be checked. OK?
1 002–01 01–01
/
2 002–02 01–02
/
3 002–03 01–03
/
/
End
Next
Page
Page 1/ 2
I.U. Address Verification
No. System–Unit Ref.–In.
4.
Touch[Back]onthe“IUAddressVerica-
tion”Screentoreturntothe“Maintenance”
Screen.
1
002–01 01–01
/
002–02 01–02
/
2
002–03 01–03
/
3
002–04 01–04
/
4
002–05 01–05
/
5
002–06 01–06
/
6
/
Page 1/ 2
I.U. Address Verification
No. System–Unit Ref.–In.
Back
Check
Next
Page
6.4.8. FunctionSetting
Thisprocedurechangesthefunctionsettingsusedtocontroltheindoor
unitaccordingtotheinstallationconditions.Incorrectsettingscancause
theindoorunittomalfunction.Performthe“FunctionSetting”accordingto
theinstallationconditionsusingtheremotecontroller.
•Refertotheindoorunitinstallationmanualfordetailsonthefunction
numbersandsettingnumbers,beforethestartoffunctionsetting.
1.
Touchthe[FunctionSetting]onthe“Maintenance”screen.The
FunctionSetting”screenisdisplayed.
Touchthe[Address]onthe“FunctionSetting”screen.The“Address”
screenisdisplayed.
2.
Touch[
]or[ ]toselecttheaddressoftheindoorunitstobecon-
gured.(Tosetallindoorunitsatthesametime,touch[All].)Touch
[OK]toreturntotheFunctionSettingscreen.
3.
Touchthe[FunctionNo.]onthe“FunctionSetting”screen.The
FunctionNo.”screenisdisplayed.
1. 2. 3.
[002–01]
[00]
[00]
Address
Function No.
Setting No.
Function Setting
Back Setting
002–01
Address
Cancel OK
All
[002–01]
[00]
[00]
Address
Function No.
Setting No.
Function Setting
Back Setting
4.
Touch[
]or[ ]tosetthefunctionnumber.Touch[OK]toreturnto
the“FunctionSetting”screen.
5.
Touchthe[SettingNo.]onthe“FunctionSetting”screen.The“Set-
tingNo.”screenisdisplayed.
6.
Touch[
]or[ ]tosetthesettingnumber.Touch[OK]toreturnto
the“FunctionSetting”screen.
4. 5. 6.
00
Function No.
Cancel OK
[002–01]
[00]
[00]
Address
Function No.
Setting No.
Function Setting
Back Setting
00
[002–01]
[00]
Function Setting
Cancel OK
Address
Function No.
Setting No.
7.
Touch[Back]toreturntothe“Maintenance”
screen.
[002–01]
[00]
[00]
Address
Function No.
Setting No.
Function Setting
Back Setting
9373328407-01_IM.indb 9 2/22/2017 11:06:26 AM
En-10
6.4.9. InstallerPasswordChange
ChangetheInstallerpassword.
1.
Touchthe[InstallerPasswordChange]onthe“Maintenance”
screen.The“InstallerPasswordVerication”screenisdisplayed.
Enterthecurrentpassword,thentouchthe[OK].
Thedefaultpasswordis“0000”(4digits).
2.
The“InstallerPasswordChange”screenisdisplayed.
Enterthenewpassword,thentouchthe[OK].Itreturnstothe
Maintenance”screen.
1. 2.
0
0
CL
5
1
6
2
7
3
8
4
9
Cancel OK
Installer Password Verification
Enter Current Password
0
CL
5
1
6
2
7
3
8
4
9
Cancel OK
Installer Password Change
Enter New Password
6.4.10. Initialization
RequireanInstallerpassword.
1.
Touchthe[Initialization]onthe“Main-
tenance”screen.EntertheInstaller
password.The“Initialization”screenis
displayed.
Whenthe[OK]istouched,thisunitrestarts
automaticallyafterinitialization.Perform
eachsetting.
Cancel OK
Initialization
Remote controller will be initialized
to the factory default setting. OK?
Whenrelocatingthesetremotecontroller,initializeit.
7. TESTRUN
•Refertotheindoorunitinstallationmanual.
Forhowtocarryoutatestrun,referto6. 4. Maintenance (Other Settings)
→ 6.4.5. Test Run.
8. ERRORCODES
Checktheerror
1.
Ifanerroroccurs,anerroriconappearsonthe“Monitormode
screen”.
Touchthe[Status]onthe“Monitormodescreen”.The“Status”
screenisdisplayed.
2.
Touchthe[ErrorInformation]onthe“Status”screen.The“Error
Information”screenisdisplayed.(Iftherearenoerrors,the[Error
Information]willnotbedisplayed.)
3.
2-digitnumberscorrespondtotheerrorcodeinthetablebelow.
Touchthe[Nextpage](or[Previouspage])toswitchtoothercon-
nectedindoorunits.
1. 2. 3.
Set Temp.
Mode
MenuStatus
Fan
Fri 10:00AM
Unoccupied
Status
Air Flow Direction
VT
Off
1 3
Off
HZ
Economy
Individual
Anti Freeze
Page 1/ 4
Monitor
Next
Page
Error
Information
02-01
14,15, 41, 44
Error Information
Page 1/ 5
Address
Error Code
Back
Next
Page
Forthedetailsoftheindoorunitoroutdooruniterror,refertotheerror
codesineachinstallationmanual.
Errorcode Contents
CC.1 Sensorerror
C2.1 TransmissionPCBerror
12.1 Wiredremotecontrollercommunicationerror
12.3
Numberexcessofdeviceinwiredremotecontroller
system
12.4 Wiredremotecontrollersystemstart-uperror
26.4 Addressduplicationinwiredremotecontrollersystem
26.5 Addresssettingerrorinwiredremotecontrollersystem
15.4 Dataacquisitionerror
9373328407-01_IM.indb 10 2/22/2017 11:06:27 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Fujitsu UTY-RNRRZ2 Installation guide

Category
Split-system air conditioners
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI