1. SAFETY PRECAUTIONS
• Let the customer keep this installation manual because it is needed
when the air conditioner or remote controller is serviced or moved.
WARNING
This mark indicates procedures which, if improp-
erly performed, might lead to the death or serious
injury of the user.
Installation of this product must be done by experienced service techni-
cians or professional installers only in accordance with this manual.
Installation by nonprofessional or improper installation of the product
may cause serious accidents such as injury, water leakage, electric
shock, or re. If the product is installed in disregard of the instructions in
this manual, it will void the manufacturer’s warranty.
Installation must be performed in accordance with regulations, codes,
or standards for electrical wiring and equipment in each country, region,
or the installing place.
Do not operate this unit when your hands are wet. Touching the unit with
wet hands will cause an electric shock.
When children can approach the unit or touch the unit, take preventive
measures.
Dispose of the packing materials safely. Tear and dispose of the plastic
packing bags so that children cannot play with them. There is the danger
of suffocation if children play with the original plastic bags.
Do not turn on the power until all installation work is complete.
CAUTION
This mark indicates procedures which, if improp-
erly performed, might possibly result in personal
harm to the user or damage to property.
When detecting the room temperature using the remote controller,
please set up the remote controller according to the following conditions.
If the remote controller is not well set, the correct room temperature will
not be detected, and thus the abnormal conditions like “not cool” or “not
heat” will occur even if the air-conditioner is running normally. :
• A location with an average temperature for the room being air
conditioned.
• Locate where is not be affected by inow of outside air such as caused
by opening and closing a door.
• Not directly exposed to the outlet air from the air conditioner.
• Out of direct sunlight.
• Away from the inuence of other heat sources.
Do not install the unit in the following areas:
• Do not install the unit near a source of heat, steam, or ammable gas.
Otherwise, re could result.
• Area lled with mineral oil or containing a large amount of splashed oil
or steam, such as a kitchen. It will deteriorate plastic parts, causing the
parts to fall.
• Install the unit in a well-ventilated place avoiding rains and direct
sunlight.
Do not touch the switches with sharp objects. Doing so will cause injury,
trouble, or electric shock.
Do not expose this unit directly to water. Doing so will cause trouble,
electric shock, or heating.
Do not set vessels containing a liquid on this unit. Doing so will cause
heating, re, or electric shock.
When installing the remote controller and cable near a source of
electromagnetic waves, separate the remote controller from the source of
the electromagnetic waves and use shielded cable.
2. ACCESSORIES
The following installation parts are supplied. Use them as required.
Name and Shape Q’ty Application
Installation manual
1
This manual
Operating manual
1
Instruction book for operation
Tapping screw (M4 x 16mm)
2
For installing the remote controller
Cable tie
1
For remote controller and remote
controller cable binding
3. ELECTRICAL REQUIREMENT
When connecting the remote controller use the following wiring.
Cable
Conductor size
(mm
2
)
Type Remarks
Remote controller
cable
0.33
Sheathed PVC
cable
Polar 3 wire
* We recommend that you purchase our service parts for the remote control-
ler cable. Contact service personnel to purchase this.
INSTALLATION MANUAL
PART NO. 9373328360
AIR CONDITIONER REMOTE CONTROLLER
(WIRED TYPE)
Contents
1. SAFETY PRECAUTIONS .............................................. 1
2. ACCESSORIES ............................................................. 1
3. ELECTRICAL REQUIREMENT ...................................... 1
4. SELECTING AN INSTALLATION LOCATION ................ 2
4.1. Dimensions ............................................................. 2
4.2. Setting the room temperature detection location .... 2
5. INSTALLING THE REMOTE CONTROLLER ................ 2
5.1. Wiring types ............................................................ 3
5.2. Installation ..................................................................3
5.3. Setting the DIP switch ............................................ 4
5.4. Connection of Remote Controller Cable ................. 4
6. TURNING ON THE POWER .......................................... 4
7. SETTING THE ROOM TEMPERATURE
DETECTION LOCATION ..................................................5
8. FUNCTION SETTING .................................................... 5
9. TEST RUN ..................................................................... 6
10. ERROR CODES ............................................................ 6
9373328360_IM_EN.indd 1 2/12/2016 5:32:42 PM
En-2
5. INSTALLING THE REMOTE
CONTROLLER
WARNING
Always use the accessories and specied installation work parts. Check
the state of the installation parts. Not using the specied parts will cause
units to fall off, water leakage, electric shock, re, etc.
Install at a place that can withstand the weight of the unit and install
rmly so that the unit will not topple or fall.
Before starting installation work, turn off the power of this unit and the
connection destination. Do not turn on the power again until installation
is completed. Otherwise, it will cause electric shock or re.
Use the accessories or specied connection cables. Do not modify
connection cables other than those specied, do not use extension
cords, and do not use independent branch wiring. The allowable current
will be exceeded and cause electric shock or re.
Install the remote controller cables securely to the terminal block.
Conrm that external force is not applied to the cable. Use remote
controller cables made of the specied wire. If intermediate connection
or insertion xing are imperfect, it will cause electric shock, re, etc.
When connecting the remote controller cable, route the cables so that
the rear case of this unit is securely xed. If the rear case is imperfectly
xed, it may cause re or overheating of the terminals.
Always fasten the outside covering of the connection cable with the
cable tie. If the insulator is chafed, electric discharge may occur.
CAUTION
Do not set the DIP switch of this unit except as specied in this manual
or the operating manual supplied with the air conditioner. Setting the
switches other than specied will cause an accident or trouble.
Before opening the case of this unit, completely discharge static
electricity charged on you body. Not doing so will cause trouble.
Do not touch the PC board and PC board parts directly with your hands.
Otherwise, injury or electric shock could result.
Be careful so that the front case does not fall after the front case screws
are removed. Otherwise, injury could result.
Install the remote controller cables 1 m away from television and radio
to avoid distorted images and noise.
Conrm the name of each terminal block of the unit and connect the
wiring in accordance with the directions given in the manual. Improper
wiring work will damage the electric parts and cause smoke and re.
Connect the connectors securely. Loose connectors will cause trouble,
heating, re, or electric shock.
Never bundle the remote controller cables , the power supply cable and
transmission cable together. Bundling these cables together will cause
miss operation.
When installing the connection cable near a source of electromagnetic
waves, use shielded cable. Otherwise, a breakdown or malfunction
could result.
4. SELECTING AN INSTALLATION
LOCATION
4.1. Dimensions
Hole
Hole × 3
Hole × 2
Unit: mm
120 18
120
15.363.5
45.3
4.512.54.5
83.5
30 33.5
23
4.5
9
6
4.2. Setting the room temperature detection
location
CAUTION
As the temperature sensor of remote controller detects the temperature
near the wall, when there is a certain difference between the room
temperature and the wall temperature, the sensor will not detect the
room temperature correctly sometimes. Especially when the outer side
of the wall on which the sensor is positioned is exposed to the open air,
it is recommended to use the temperature sensor of the indoor unit to
detect the room temperature when the indoor and outdoor temperature
difference is signicant.
The detection location of the room temperature
can be selected from the following 2 methods.
Choose the detection location that is best for the
installation location.
The temperature sensor of the indoor unit or the
remote controller can be used to detect the room
temperature.
A sensor of the indoor
unit (inside)
A sensor of the remote
controller (inside)
To use this function, set the Function setting of the indoor unit
accordingly.
If using the remote control sensor, setting is required. Refer to
7. SETTING THE ROOM TEMPERATURE DETECTION LOCATION.
9373328360_IM_EN.indd 2 2/12/2016 5:32:42 PM
En-3
5.2.1. INSTALLING THE REMOTE CONTROLLER
Open the operation panel on the front of the remote controller, remove the
2 screws indicated in the following gure, and then remove the front case of
the remote controller.
When installing the remote controller, remove the connector from the
front case.
The wires may break if the connector is not removed and the front case
hangs down.
When installing the front case, connect the connector to the front case.
Fig. 1
SET BACK
Front case
(back side)
Screws
Connector
Rear case
When remote controller cable is embedded
(1) Embed the remote controller cable and box.
(2) Pass the remote controller cable through the hole in the rear case and
connect the remote controller cable to the remote controller terminal
board specied in Fig. 2.
Tightening torque 0.8 to 1.2 N•m (8 to 12 kgf•cm)
(3) Clamp the remote controller cable sheath with the cable tie as shown in
Fig. 2.
(4) Cut off the excess cable tie.
(5) Install the rear case to the wall, box, etc., with 2 screws (Fig. 3).
Fig. 2
1. 12V
(Red)
1. 12V
(Red)
Cable tie
Hole
2. Signal
(White)
2. Signal
(White)
7 7 7
3. COM
(Black)
3. COM
(Black)
Unit : mm
CAUTION
When connecting the remote
controller cables, do not over
tighten the screws.
Fig. 3 [Example]
Rear case
Connector
Box
Rear
case
Remote controller
cable
Trap (remote controller cable)
Seal the wiring hole of the remote
controller cable with putty.
Connector
Screws
Remote controller
cable
5.1. Wiring types
5.1.1. Single control
1 2 3
1 2 3
Indoor unit
Remote controller
When there is an
earth (ground)
cable.
Remote controller
cable
5.1.2. Group control
A number of indoor units can be operated at the same time using a single
remote controller.
Depending on the model, some indoor units cannot be connected for
group control. (Group control is available for the duct type, the cassette
type and the ceiling type indoor unit.)
Some functions may become unusable, depending on the combination of
the indoor units that are connected in a group.
(1) Wiring method (indoor unit to remote controller)
EXAMPLE: Single Type
1 2 3
1 2 3
1 2 3 1 2 3 1 2 3
Indoor unit 0
Remote controller
cable
Remote controller
When there is an earth (ground) cable.
Indoor unit 1 Indoor unit 2 Indoor unit 3
(2) Indoor unit address setting
Set each indoor unit address using the DIP switch of each indoor unit.
(Refer to the installation manual for the indoor unit.)
5.2. Installation
CAUTION
Perform wiring so that water does not enter this unit along the external
wiring. Always install a trap to the wiring or take other countermeasures.
Otherwise it will cause trouble or electric shock or re.
When connecting a remote controller cable to the remote controller
terminal block, please use the specied torque to tighten screws. If you
over-tighten screws, they will break the terminal unit.
Be careful to avoid breaking the cable by over-tightening the cable tie.
9373328360_IM_EN.indd 3 2/12/2016 5:32:43 PM
En-4
5.3. Setting the DIP switch
When using a battery (memory backup)
DIP Switch 1
OFF ON
ON
Front case (back side)
Change the DIP switch setting to use batteries. (The DIP switch is not set to
use batteries at the factory.)
Change DIP switch No. 6 from OFF to ON.
If batteries are not used, all of the settings stored in memory will be deleted
if there is a power failure.
CAUTION
Conrm whether the wiring work for outdoor unit has been nished.
Conrm whether the cover for electric control box on the outdoor unit is
close.
After turning off the power, wait 30 seconds or more before turning on it
again. The FUNCTION SETTING doesn’t become effective if it doesn’t
do so.
NO.
Switch state
Detail
OFF ON
DIP switch 1
1
Cannot be used. (Do not
change)
2
Cannot be used. (Do not
change)
3
Follow the
selection in
8.FUNCTION
SETTING
Invalidity
Filter reset operation
and lter display
4
Cannot be used. (Do not
change)
5
Cannot be used. (Do not
change)
6
Invalidity
Validity
Memory backup setting
* Set to ON to use bat-
teries for the memory
backup. If batteries are
not used, all of the set-
tings stored in memory
will be deleted if there
is a power failure.
(
Factory setting)
5.4. Connection of Remote Controller Cable
5.4.1. WHEN CONNECTING TO THE EXCLUSIVE
TERMINAL BLOCK
Connect the end of remote controller cable directly to the exclusive terminal
block.
3
2
1
*
M4 screw
Terminal block
Indoor unit
side
* Earth (Ground) the remote
controller if it has an earth
(ground) wire.
Black
White
Red
Remote controller
cable
Remote controller
terminal block
Outdoor unit /
power supply
terminal block
Indoor unit
PCB
It may be failed if it is connected to the outdoor unit or the terminal block
for power supply.
6. TURNING ON THE POWER
CAUTION
Recheck the wiring. Incorrect wiring will cause trouble.
(1) Check the remote controller wiring and DIP switch settings.
(2) Install the front case.
* When installing the front case, connect the connector to the front case
(in 5. INSTALLING THE REMOTE CONTROLLER).
(3) Check the indoor and outdoor unit wiring and circuit board switch
settings, and then turn on the indoor and outdoor units. After “
” has
ashed on the set temperature display for several seconds, the clock
display will appear in the center of the remote controller display.
SU
MO
TU
WE
TH FR
SA
9373328360_IM_EN.indd 4 2/12/2016 5:32:44 PM
En-5
7. SETTING THE ROOM TEMPERATURE
DETECTION LOCATION
The detection location of the room temperature can be selected from the
following 2 examples. Choose the detection location that is best for the
installation location.
A. Indoor unit setting (factory setting)
The room temperature is detected by the indoor unit temperature sensor.
(1) When the “
” button is pressed, the lock
display ashes because the function is locked at the factory.
A
Indoor unit
B. Indoor unit/remote controller setting (room temperature sensor
selection)
The temperature sensor of the indoor unit or the remote controller can be
used to detect the room temperature.
When use this function, set “Indoor room temperature sensor switching
function (Function Number:42)” of “8. FUNCTION SETTING” to “Yes(01)”.
(1) Enable the room temperature sensor selection in FUNCTION SETTING,
which will be described later.
(2) Press the “
” button for 5 seconds or
more to select the temperature sensor of the indoor unit or the remote
controller.
B
Indoor unit
CAUTION
When select the “Remote controller setting”, if the
detected temperature value between the temperature
sensor of the indoor unit and the temperature sensor of
the remote controller varies signicantly, it is likely to
return to the control status of temperature sensor of the
indoor unit temporarily.
As the temperature sensor of remote controller detects the temperature
near the wall, when there is a certain difference between the room
temperature and the wall temperature, the sensor will not detect the room
temperature correctly sometimes. Especially when the outer side of the
wall on which the sensor is positioned is exposed to the open air, it is
recommended to use the temperature sensor of the indoor unit to detect
the room temperature when the indoor and outdoor temperature difference
is signicant.
The temperature sensor of the remote controller is not only used when
there is a problem in the detection of the temperature sensor of the indoor
unit.
NOTES
If the function to change the temperature sensor is used as shown in
example A (other than example B), be sure to lock the detection location.
If the function is locked, the lock display
will ash when the
” button is pressed.
8. FUNCTION SETTING
This procedure changes the function settings used to control the indoor
unit according to the installation conditions. Incorrect settings can cause
the indoor unit to malfunction. This procedure should be performed by
authorized installation or service personnel only.
Perform the “FUNCTION SETTING” according to the installation conditions
using the remote controller.
Refer to the indoor unit installation manual for details on the function
numbers and setting numbers, before the start of function setting.
(1) Press the “
” button, “ ” button and
” button simultaneously for more than 5 seconds to enter the
function setting mode.
SU
MO
TU
WE
TH FR
SA
(2) Press the “ ” button to select the indoor unit number.
SET BACK
SU
MO
TU
WE
TH FR
SA
Unit number of
INDOOR UNIT
(3) Press the “
” button or “ ” buttons to select the function
number.
Function
number
SU
MO
TU
WE
TH FR
SA
(4) Press the “
” button, “ ” button to select
the setting value. The display ashes as shown to the right during setting
value selection.
(5) Press the TIMER SET button to conrm the setting.
Press the TIMER SET button for a few seconds until the setting value
stops ashing.
If the setting value display changes or if “- -” is displayed when the
ashing stops, the setting value has not been set correctly.
(An invalid setting value may have been selected for the indoor unit.)
Setting value
SU
MO
TU
WE
TH FR
SA
(6) Repeat steps 2 to 5 to perform additional settings.
Press the “
” button, “ ” button and
” simultaneously again for more than 5 seconds to cancel the
function setting mode. In addition, the function setting mode will be
automatically canceled after 1 minute if no operation is performed.
(7) After completing the FUNCTION SETTING, be sure to turn off the power
and turn it on again.
9373328360_IM_EN.indd 5 2/12/2016 5:32:46 PM
En-6
9. TEST RUN
(1) If the operation lamp is on, press the START/STOP button to turn it off.
(2) Press the “ ” button and
button at the same time for
more than 2 seconds to start the test run.
The operation lamp will light up and “ ” will be displayed on the set
temperature display.
* Perform the test run for 60 minutes.
* Pressing the START/STOP button will stop the test run.
Test run display
10. ERROR CODES
If you use a wired remote controller, error codes will appear on the remote
controller display.
If you use a wireless remote controller, the lamp on the IR receiver unit
will output error codes by way of blinking patterns. Refer to the indoor unit
installation manual for details on the error codes.
9373328360_IM_EN.indd 6 2/12/2016 5:32:46 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Fujitsu UTG-UKGB-W Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI