Contour Next LINK Quick Reference Manual

Type
Quick Reference Manual
Automatically send
results to the Pump?
Always
Ask me
Never
SEND OPTIONS
Enter this Meter ID
into your pump:
123456
/
OK
Go Back
CONNECT TO PUMP
/
Accept
Turn Off
AUTOLOG
AutoLog is On.
70–130
70–180
/
Accept
Change
CURRENT TARGET
8:O3AM
MAIN MENU
Basal
Reservoir + Set
Utilities
CONNECT TO PUMP
/
OK
Go Back
Connect to a
Medtronic Pump?
HIGH AND LOW LIMITS
/
Accept
Change
High: 250 mg/dL
Low: 70 mg/dL
Initial Setup is complete.
OK
REVIEW METER ID
1. 123456
2. ------
3. ------
8:O3AM
METER ID MENU
Add ID
Delete ID
Review ID
OK
English
Espanol
LANGUAGE
METER ID MENU
Add ID
Delete ID
Review ID
For a full list of important warnings and limitations of your system, please see the INDICATIONS FOR USE,
IMPORTANT SAFETY INFORMATION, WARNINGS and PRECAUTIONS in your CONTOUR
®
NEXT LINK meter
userguide.
CONNECT TO PUMP
/
OK
Go Back
Enter this Meter ID
into your Pump:
123456
UTILITIES MENU
Alarm Clock
Connect Devices
Block
DEVICE OPTIONS
PC Connect
Meters
Remotes
METER OPTION
Off
On
METER ID MENU
Add ID
Delete ID
Review ID
DELETE METER ID
1. aaaaaa
2. bbbbbb
3. ------
ADD METER ID
1 2 3 4 5 6
For a full list of important warnings and limitations of your system, please see the INDICATIONS FOR USE,
IMPORTANT SAFETY INFORMATION, WARNINGS and PRECAUTIONS in your
CONTOUR
NEXT
LINK meter
USB
Connector
TOP VIEW
Selection/
Scrolling Buttons
Test Strip Port
Display
Screen
Top Menu
Button
Protective
USB Cap
Note: Check the units of measure of your meter.
See your meter user guide for complete instructions.
FRONT VIEW
10:30 AM l 3/11
Reminder
Notes
93
mg
dL
Before Meal
10/10/10
8:03 AM
Accept
Change
CURRENT DATE & TIME
8:O3
AM
TIME/DATE SET
8:03A
1OOCT2O1O
Press ACT to Change
Initial Setup of the Meter and Connection to Compatible MiniMed
®
Insulin Pump
1
Remove the USB cap to reveal the USB connector.
The CONTOUR
®
NEXT LINK meter has a permanent
rechargeable battery. Before you do anything else,
charge your meter with the wall charger included
with your kit or by plugging the USB connector into
a computer. Be sure the computer is turned on. Your
meter will briefl y display “Do Not Test—Charging”
and the test strip port light will fl ash.
You cannot do a blood glucose test while the
battery is charging. When charging is fi nished,
the test strip port light will turn off. Unplug your
CONTOUR NEXT LINK meter to test.
2
To begin setup,
hold down
Menu button
for several
seconds until
the meter turns on.
3
Choose your
language and
press OK.
4
Press OK on the next screen to
begin the connection process.
NOTE: Pump refers to your
compatible MiniMed Insulin
Pump.
5
STOP. Do NOT press
ANY buttons.
This screen displays the
meter ID number (in the
bottom left corner). This ID is needed to complete
the connection process.
Put down your meter. Pick up the compatible
MiniMed Insulin Pump and continue with Step 6.
6
Press ACT to go to
the MAIN MENU.
Scroll to Utilities by
pressing the down
arrow. Press ACT.
7
Scroll to Connect Devices from the
UTILITIES MENU and press ACT.
8
Select On and press ACT. If you are
replacing a meter, go to Step 9. If
you are adding a new meter, go to
Step 11.
9
If replacing a meter, select Delete ID
and press ACT.
10
If you have multiple meter IDs,
repeat Step 9 for each one.
11
To add a new meter, select Add ID
and press ACT. Refer to Step 5 (or
see meter back) to fi nd meter ID.
13
Return to your
CONTOUR NEXT LINK
meter. After you
have entered the
meter ID into your
compatible MiniMed Insulin Pump, press OK.
12
Select Review ID on
your compatible
MiniMed Insulin Pump
to confi rm that your
CONTOUR
®
NEXT LINK
meter ID has been
correctly entered. If
incorrect, go back to
Step 9.
NOTE: For detailed instructions, see
your compatible MiniMed Insulin
Pump user guide.
14
SEND OPTIONS controls
how your meter will
send blood glucose
readings to your
compatible MiniMed
Insulin Pump.
Choose the SEND OPTION that is best for you.
Always = Meter will always send results.
Ask Me = Meter will ask you before sending results.
Never = Meter will never send results.
16
Choose your
AUTOLOG settings.
AUTOLOG allows
you to mark a test as
Before Meal, After Meal or No Mark.
17
The meter comes
preset with the de-
fault blood glucose
target ranges as
shown. Accept the
default blood glucose target ranges or Change them
after talking to your health care professional.
18
Follow the display prompts
to set your meter High and Low
Limits. Choose Accept to use
the default setting (250 mg/dL
for the meter high limit and
70 mg/dL for the meter low
limit). Choose Change if you
wish to use different limits.
Connecting Meter to Compatible MiniMed
Insulin Pump
Choosing Meter Send Options
Set Meter Date/Time to Match MiniMed Pump
Additional Meter Settings
SETUP IS NOW COMPLETE!
Setting Up the Meter
/
= Help
Charging the Meter
85591681 Rev. 12/16
NOTE: High and Low Limits can only be set outside
your selected Target range(s). Targets can only be set
inside your selected High and Low Limit(s). For
additional information, you may contact Customer
Service at 800-348-8100, available Monday through
Sunday, 8:00 am through 12:00 Midnight, Eastern Time.
Use the up and down arrow buttons
to enter the six character meter ID
shown on the meter screen.
Press ACT after
each character
entry.
Then scroll to Meters and
press ACT.
8:O3 AM
METER BG
mg/dL
93
93
mg
dL
Before Meal
01:33PM l 11/10
Reminder
Notes
QUICK REFERENCE GUIDE
Uses only CONTOUR
®
NEXT
Blood Glucose Test Strips
Wireless Blood Glucose
Monitoring System
15
The date and time on
your meter must match
the date and time on
your MiniMed Pump.
Pick up MiniMed
Pump.
Press ACT to go
to the MAIN
MENU. Scroll to
Utilities and
press ACT. Scroll to Time/Date and press ACT.
Select a time format and press ACT. Note the time
and date.
Return to your meter. Follow instructions on your
meter to change the time and date to match your
compatible MiniMed Insulin Pump.
AUTOLOG
Before Meal
After Meal
No Mark
93
mg
dL
Sent, Before...
10:30AM l 11/10
Reminder
Notes
93
mg
dL
Sent, Before...
RESULTS SENT
OK
WARNING:
The meter, lancing device and lancets are for single patient use. Do not share them with anyone including
other family members. Do not use on multiple persons.
1,2
All parts of the kit are considered biohazardous and can potentially transmit infectious diseases, even after
you have performed cleaning and disinfection.
Always wash your hands well with soap and water and dry them well before and after testing, handling the
meter, lancing device, or test strips.
For complete instructions on cleaning and disinfecting your meter and lancing device, please see your meter
user guide.
2
Remove lancing
device endcap.
Insert the lancet
into lancing device
and twist off
protective cap.
1
Insert test strip
and wait for APPLY
BLOOD message.
3
Re-cap and dial
to desired lancing
depth.
4
Obtain your
blood drop.
5
Touch the tip of
the test strip to
the drop of blood.
If the fi rst blood
drop is not
enough,
the meter will beep
twice and display
STRIP UNDERFILLED. You have about 30 seconds to
apply more blood to the same strip.
8
Select Reminder to set a reminder for your next
test. Select Notes to add more information to the
result. Remove test strip.
9
Remove the test strip and the meter will
turn off in 3 minutes. Or hold down the
Menu button to turn off the meter.
Obtaining the Blood Drop
Testing the Blood Drop
Sending Results to Your Compatible MiniMed
Insulin Pump
Reminder and Notes
Turn Meter Off
7
If Ask Me or Always was selected in Send Options
during Setup, results can be sent to your
compatible MiniMed Insulin Pump.
Press OK to move to the next screen.
6
If AUTOLOG is on, you can choose to record your
result as: Before Meal, After Meal or No Mark
for the test result.
Testing Your Blood
Materials for Testing
Lancing Device
CONTOUR
®
NEXT
Test Strip
Lancet
CONTOUR
®
NEXT LINK
Blood Glucose Meter
The lancing device graphics are for illustration
purposes only. Your lancing device may look
different. Refer to your lancing device insert
fordetailed instructions on preparing the
lancingdevice.
1
US Food and Drug Administration. Use of fi ngerstick
devices on more than one person poses risk
for transmitting bloodborne pathogens: initial
communication. US Department of Health and
Human Services; update 11/29/2010.
http://www.fda.gov/MedicalDevices/Safety/
AlertsandNotices/ucm224025.htm
2
Centers for Disease Control and Prevention. CDC
clinical reminder: use of fi ngerstick devices on more
than one person poses risk for transmitting bloodborne
pathogens. US Department of Health and Human
Services; 8/23/2010.
http://www.cdc.gov/injectionsafety/Fingerstick-
DevicesBGM.html
See your C ONTOUR NEXT LINK user guide,
lancing device insert and compatible MiniMed
Insulin Pump user guide for full instructions.
Call 800-348-8100 (available Monday through
Sunday, 8:00 am through 12:00 Midnight, Eastern
Time) with any questions
or visit www.diabetes.ascensia.com
For information on patents, and related
licenses, see:
www.patents.ascensia.com
For In Vitro Diagnostic Use
Ascensia, the Ascensia Diabetes Care logo,
Clinilog, Contour, Glucofacts, and the NoCoding
logo are trademarks and/or registered trademarks
of Ascensia Diabetes Care Holdings AG. Bolus
Wizard, CareLink, Guardian, MiniMed, Paradigm,
and Revel are trademarks and/or registered
trademarks of Medtronic MiniMed, Inc.
© 2017 Ascensia Diabetes Care Holdings AG.
All rights reserved.
Distributed by:
Ascensia Diabetes Care US Inc.
5 Wood Hollow Road
Parsippany, NJ 07054
References
85591681 Rev. 12/16
  • Page 1 1
  • Page 2 2

Contour Next LINK Quick Reference Manual

Type
Quick Reference Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI