Application sheet
BasicRail / BasicClip
Carpet / tiles / parquet / laminate / synthetics
Liquid screed
1
2
3
4
5
1 Carpet / tiles / parquet
2 Liquid screed (≥ CAF F5) 50 mm
3 FH composite pipe (16 mm)
4 Basic Insulation overlap panels 35-3 35 mm
5 Basic perimeter insulation
Floor nish NA mm Carpet / tiles / parquet / laminate / synthetics
Construction height 85 mm Height excluding oor nish
Weight ~ 110 kg / m² Weight excluding oor nish
Thermal resistance R 0,77 m²K / W The minimum thermal resistance requirement of EnEV is fullled.
Thermal transmission coecient U 1,06 W / m²K
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN
Impact subsonic noise reduction 29 dB Calculated value according to DIN 4109; applies to concrete slabs
thicker than 12 cm (DIN 4109: m² > 276 kg/m²).
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
A screed thickness of 60 mm must be maintained with CAF-F4 tile screeds.
The screed thicknesses must be adjusted in case of higher design load or point load
values.
Observe all installation instructions and manufacturer’s instructions.
Construction
According to EnEV, EN 1264, DIN 4109, 1055 and 18560
Construction number 116
Technical Data Floors/ceilings between rooms at the same temperature
© Danfoss 11/2008
VA.CT.C1.02