  • Hello! I've reviewed the installation instructions for the Minka Group light fixtures 6411-84/66A-L, 6412-84/66A-L and 6413-84/66A-L. This document provides detailed steps for mounting, wiring, and selecting the color temperature (CCT) of the fixture. It also mentions that the fixture is dimmable with compatible wall switches. I'm here to help answer any questions you have about installing or using this device.
  • How do I select the desired color temperature?
    Can I dim this light fixture?
    What size are the junction box screws?
W
A R N I N G ! S H U T P O W E R O F F AT F U S E O R C I R C U I T B R E A K ER .
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU
DISJONCTEUR.
INSTALLATION INSTRUCTIONS
Item# 6411/6412/6413-84/66A-L
READ AND SAVE THESE INSTRUCTIONS
MOUNTING THE FIXTURE (Fig. 1)
1. Shut off power at the fuse box or circuit breaker box
and remove the old fixture including the mounting
hardware.
2. Carefully remove the new fixture from the carton and
check that all parts are included as shown in the
illustration.
3. Loosen mounting screws (B). Remove mounting
plate (A) from fixture. Note: Do not remove any other
parts.
4. Attach mounting plate (A) to junction box (Not
included) using junction box screws (C) (Size: 8-
32*1’’L).
CONNECTION THE WIRES (Fig. 2)
5. Connect electrical wires as shown in Fig. 2 making
sure that all wire connectors (D) are secured. If your
junction box has a ground wire (green or bare
copper), connect the fixture’s ground wire to it.
Otherwise, connect fixture’s ground wire directly to
mounting plate (A) using green screw provided.
6. Tuck wire connectors neatly into the junction box.
FINISHING THE INSTALLATION (Fig. 1)
7. There are five CCTs (2700K / 3000K / 3500K /
4000K / 5000K) with this fixture. Select the desired
CCT by using switch inside canopy of fixture.
8. Align the back plate of fixture onto mounting plate
(A) and secure with mounting screws (B).
Your installation is now complete. Return power
and test the fixture.
IMPORTANT: THE FIXTURE SHOULD BE
INSTALLED BY A QUALIFIED ELECTRICIAN TO
ENSURE PROPER WIRING AND
INSTALLATION.
Dimming: Dimmable with ELV and/or LED
compatible wall dimmer switches.
Fig.1
Mounting plate
A
-022-127100
(6411/6412-84/66A-L)
Junction Box Screws *2
Junction Screws *2
Wire Nuts *3
Mounting plate
A-022-131100
(6413-84/66A-L)
/