TableofContents
Solutionoverview...........................................3
Productoverview...........................................4
HowtoaddadevicetoaZ-WaveNetwork......................5
HowtotesttheZ-Wavedevice................................6
HowtoprogramtheZ-Wavedevice............................7
Troubleshooting............................................10
Specications..............................................11
2
AXIST8343AlertButton
Solutionoverview
Solutionoverview
ThedeviceisZ-Wave®enabledandfullycompatiblewithanyZ-Waveenablednetwork.ThedevicecanbesetupinaZ-Wave
networktocommunicatedirectlywithotherenddevicessuchaslightingcontrollers,ortoreportdirectlytoaZ-Wavecontrollerlike
theAXISM5065PTZNetworkCamera.
3
AXIST8343AlertButton
Productoverview
Productoverview
1.Alertbutton
2.Rearcover
3.LEDindicator
4.Batterycompartments
5.Linkbutton
6.Rearcoverlatch
4
AXIST8343AlertButton
HowtoaddadevicetoaZ-WaveNetwork
HowtoaddadevicetoaZ-WaveNetwork
Autoinclusion
Thedetectorsupportstheautoinclusionfeaturewhereitwillautomaticallyenterlearningmode(inclusion/exclusion)whenrst
poweredup.
1.Carefullyremovethefrontcoverbypullingthebottomofthefrontcover.
2.PutaZ-Wavecontrollerintoinclusionmode.
3.Insert2AAA-batteries(1,5V)intothebatterycompartmentwiththecorrectpolarity.TheLEDonthedeviceshouldturnON
4.EnterPINnumberintotheZ-Wavecontroller.ThePINnumbercanbefoundonthedevice.Seewhereintheinstallation
guide.
5.TheinclusionprocessshouldbecompletedwhentheLEDstopsblinking
6.Performtestbeforeyouretthebatterycover.SeeHowtotesttheZ-WaveDevice.
Manualinclusion
YoucanalsochoosetomanuallyaddtheZ-Wavedevicetoacontroldevice.Pleasefollowthestepsdescribedbelow.
Note
Forbestresults,excludethedevicebeforestartingtheinclusionprocess.SeeManuallyexclusion
1.Carefullyremovethefrontcoverbypullingthebottomofthefrontcover.Thereisalinkbuttonwhichisusedtoputthe
deviceinlearningmode(inclusion/exclusion).
2.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
3.EnterPINnumberintotheZ-Wavecontroller.ThePINnumbercanbefoundonthedevice.Seewhereintheinstallation
guide.
4.TheinclusionprocessshouldbecompletedwhentheLEDstopsblinking
5.Performtestbeforeyouretthebatterycover.SeeHowtotesttheZ-WaveDevice.
Manualexclusion
1.Detachthefrontcover.
2.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
3.TheexclusionprocessshouldbecompletedwhentheLEDstopsblinking.
4.Retthefrontcover.
5
AXIST8343AlertButton
HowtotesttheZ-Wavedevice
HowtotesttheZ-Wavedevice
AnActionruleneedstobecreatedontheZ-WavecontrollerfortheAlertbuttontocontrolotherdevices.Actionrulesareuser
denedelementsinthecontrollerthatdetermineswhatactionstotakewhenaneventoccurs.TheAlertbuttontriggerstheeventfor
theActionrulewhichthencontrolsotherdevicessuchasplugsordimmers,oractivateanalarm.Analarmistriggeredafterashort
pressoftheAlertbutton.Todisarm,performa10secondlongpress.
AfteryouhaveincludedthedeviceinthenetworkwiththeZ-Wavecontroller,theAlertbuttonwillsenddataaboutits
batterypowertothecontrollerafterabout2minutes.Afterthat,itwillonlysenddataoncethebuttonispressed.
6
AXIST8343AlertButton
HowtoprogramtheZ-Wavedevice
HowtoprogramtheZ-Wavedevice
Note
ProgrammingZ-WavedevicesusingaZ-Wavecontrollerisrecommendedforexperiencedusersonly.
Z-WaveGroup
ThedetectorsupportseitheroneoftwoZ-WaveAssociationGroups:
Group1:Associationwith1Controllernode.
Group2:Associationwith4nodes(i.e.enddevicessuchassmartplugsandotherlightingcontrollers).Thisallowsthedetectorto
transfercommandsdirectlytoenddeviceswithouttheparticipationofthecontroller.Thishastheeffectthatwhenthedetector
triggers,alldevicesassociatedwithdetectorwillbeoperated.
Note
Association-groupsupportcanvaryamongZ-WaveControllers.TheAXISM5065supportsZ-WaveAssociationGroup1.
Group1commands:
Whendevicestatusbeingchanged,theunitwillsendNoticationcommandtothenodeofGroup1.
Upondevicestatusbeingchanged,theunitwillcheckitsbatterystatus.Whenthebatteryleveloftheunitdropstoan
unacceptablelevel,theunitwillemitanoticationreporttothenodesofGroup1.
WhenyouperformaFactoryResettheunitwillsendaDeviceResetLocallynoticationtothenodeofGroup1.
Group2commands:
WhentheUpkeyispressed,theunitwillsendaBASICSETcommandwhichcontainsavaluethatisadjustable,tothe
nodesofGroup2.WhentheDownkeyispressed,aBASIC_SETcommandwillalsobesenttothenodesofGrouping2.
Z-WavePlus® ®
®info
RoletypeNodetypeInstallerIconUserIcon
SlaveSleepingreportZ-WavePlusnodeNoticationSensorNoticationSensor
Version
Protocollibrary3(Slave_Enhance_232_Library)
Protocolversion4.61(6.71.01)
Manufacturer
ManufacturerIDProductTypeProductID
0x03640x00040x0001
AGI(AssociationGroupInformation)table
GroupProleCommandClass&Command
(List)Nbytes
GroupName(UTF-8)
1GeneralNoticationReport
DeviceResetLocallyNotication
Lifeline
2ControlBasicSetPIRControl
Notication
7
AXIST8343AlertButton
HowtoprogramtheZ-Wavedevice
EventTypeEventEvent
Parameters
Length
EventParameters
Programstarted0x0C0x01null
Programcompleted0x0C0x03null
Powerisappliedfortherst
time
0x080x01null
Battery
BatteryReport(value)Description
0xFFBatteryislow
Commandclasses
Thisproductsupportsthefollowingcommandclasses:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_BATTERY
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_NOTIFICATION_V4
Wakeupcommandclass
AfterthedetectorhasbeenincludedintoaZ-Wavenetworkitwillgotosleep,butitwillsendawake-upnoticationcommandto
thecontrollerperiodicallyatapresetperiod.Thedetectorwillstayawakeforatleast10secondsandthengobacktosleepto
conservebatterylife.
Thetimeintervalbetweenwakeupnoticationcommandscanbesetinthewakeupcommandclassbasedontherangevaluesbelow:
Minimumwakeupinterval600s(10minutes)
Maximumwakeupinterval86400s(1day)
8
AXIST8343AlertButton
HowtoprogramtheZ-Wavedevice
Defaultwakeupinterval14400s(4hours)
Wakeupintervalstepseconds600s(10minutes)
9
AXIST8343AlertButton
Troubleshooting
Troubleshooting
Ifyoucan’tndwhatyou’relookingforhere,trythetroubleshootingsectionataxis.com/support
Action-
/Status
DescriptionLEDindication
Nonode
ID.
TheZ-Wavecontrollercouldnotndthedeviceanddidnotprovideanode
ID.
2-secondon,2-secondofffor2
minutes.
1.Pressthelinkbutton3timeswithin1.5secondstoputthedeviceinto
exclusionmode.
2.Within1secondofstep1,pressthelinkbuttonagainandholdfor5
seconds.
Factory
Reset
(This
proce-
dure
should
onlybe
used
when
thecon-
trolleris
inoper-
able.)
3.NodeIDisexcluded.Thedevicerevertstofactorydefaultstate.2-secondon,2-secondofffor2
minutes.
Failedorsuccessfulresultsinincluding/excludingtheIDcanbeviewedontheZ-WaveController.
Tablebelowliststypicalproblemsencountered:
SymptomPossibleCauseRecommendation
Cannot
carryout
inclusion
andasso-
ciation.
1.Thedeviceisstillconnected,orhasbeenaccidentally
included,toapreviousnetwork.
2.TheenteredPINcodeisincorrect.
3.Thebatteryhasrunoutofpower.
4.Batterypolarityisreversed.
5.Deviceismalfunctioning.
1.Excludethedevicebefore
includingitagain.
2.Makesureyouhaveentered
thecorrectPINcode.
3.Replacethebattery.
4.Retthebatterywiththe
correctpolarity.
5.Ensurethedeviceisworking
properly.
PressAlert
Button,
LEDillu-
minates,
butthere-
ceiver(s)
haveno
response
1.Thedeviceisstillconnected,orhasbeenaccidentally
included,toapreviousnetwork.
2.DistancebetweentheAlertButtonandthereceiver(s)toofar.
3.Thebatterieshaverunoutofpower.
4.Detectorismalfunctioning.
1.Excludethedevicebefore
includingitagain.
2.Moveclosertothereceivers.
3.Replacebatteries.
4.Ensurethedetectoris
workingproperly.
Note
Forbestresults,excludethedevicebeforestartingtheinclusionprocess.Formoredetailsseetheinstallationguide.
10
AXIST8343AlertButton
Specifications
Specifications
Tondthelatestversionoftheproduct’sdatasheet,gototheproductpageataxis.comandlocateSupport&Documentation.
Specications
BatteryAAABatteryx2
Batterylife1year*
RangeUpto100m(328ft)lineofsight
Operatingfrequency908.42MHz(US),922.5MHz(JP),868.42MHz(EU)
FCCIDFU5AC136
Specicationsaresubjecttochangewithoutnotice
*measuredat1triggersperday
1 1
UserManualVer.M2.2
AXIST8343AlertButtonDate:September2018
©AxisCommunicationsAB,2017-2018PartNo.T10117077
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Axis Communications T8343-EUR User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI